Tray Cable 2 Conductor Control Cable
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Tray Cable 2 Conductor Control Cable
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TYPE | NAME | Section Area(mm 2 ) |
|
| |||||
| 0.75 | 1 | 1.5 | 2.5 | 4 | 6 | 10 |
| |
| No. of Core | Application Site | |||||||
KVV | Copper Conductor, PVC Insulated and Sheathed Control Cable | 2-48 | 2-14 | 2-10 | Permanent installation indoors, in cable ditches or pipes | ||||
ZR-KVV | Flame Retardant Copper Conductor, PVC Insulated and Sheathed Control Cable | ||||||||
NH-KVV | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed Control Cable | ||||||||
KVVP | Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable | 2-48 | 2-14 | 2-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required | ||||
ZR-KVVP | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable | ||||||||
NH-KVVP | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding Shielded Control Cable | ||||||||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 4-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required | ||||
ZR-KVVP2 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | ||||||||
NH-KVVP2 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | ||||||||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable | 7-48 | 4-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches, directly buried, Be able to withstand stronger external mechanical force | |||
ZR-KVV22 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable | ||||||||
NH-KVV22 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Steel tape Armored Control Cable | ||||||||
KVV32 | Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | 19-61 | 7-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches, vertical shaft Be able to withstand stronger external mechanical force | |||
ZR-KVV32 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | ||||||||
NH-KVV32 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | ||||||||
KVVR | Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | 4-48 | - | - | Installation indoors where flexibility and movability are required | ||||
ZR-KVVR | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | ||||||||
NH-KVVR | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Flexible Control Cable | ||||||||
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | 4-16 | 4-48 | - | - | Installation indoors where flexibility shielding and movability are required | |||
ZR-KVVRP | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | ||||||||
NH-KVVRP | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |