Flame Retardant Rubber Flexible Mining cable
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Flame Retardant Rubber Flexible Mining cable
Standard: The products are produced according to the standard MT 818.1~14-1999, namely The Flame Retardant Cables for Coal Mines , GB/T12972-2008, namely the rubber flexible cable for mining, and the enterprise standard. We can also produce products according to standard IEC, BS, DIN, and American standard with the needs of customer.
Performance:
The rated voltage is 300/500v, 0.38/0.66kv, and 0.66/1.14kv.
The continuous maximum conductor temperature for operation of the cable is 65°C
The Min. ambient environment for operation is -35°C;
The bending radiuas:(D refers to diameter) D≤25mm: ≥4D; D>25mm: ≥6D
Types and Name
type | Name |
UY MY | EPR insulated (flame-retardant) neoprene sheathed moving rubber flexible cable for mining |
UYP MYP | EPR insulated (flame-retardant) neoprene sheathed screened moving rubber flexible cable for mining |
UC MC | EPR insulated (flame-retardant) neoprene sheathed flexible cable for miner |
UCP MCP | EPR insulated (flame-retardant) neoprene sheathed screened flexible cable for miner |
UZ UZP MZ MZP | EPR insulated (flame-retardant) neoprene sheathed cable for mining electric drill |
UYQ MYQ | insulated (flame-retardant) neoprene sheathed light flexible cable for mining |
Technical data
Nominal cross-sectinal area of conductor (mm2) | 0.75 | 1.0 | 1.5 | 2.5 | 4.0 | 6.0 | 10 | |||||||
Number of cores | Sheath thickness (mm) | O.D (mm) | Sheath thickness (mm) | O.D (mm) | Sheath thickness (mm) | O.D (mm) | Sheath thickness (mm) | O.D (mm) | Sheath thickness (mm) | O.D (mm) | Sheath thickness (mm) | O.D (mm) | Sheath thickness (mm) | O.D (mm) |
2 | 1.2 | 7.3 | 1.2 | 7.7 | 1.2 | 8.5 | 1.2 | 9.7 | 1.2 | 10.7 | 1.2 | 11.7 | 1.5 | 15.6 |
3 | 1.2 | 7.6 | 1.2 | 8.0 | 1.2 | 9.0 | 1.2 | 10.3 | 1.2 | 11.3 | 1.5 | 13.0 | 1.5 | 16.5 |
4 | 1.2 | 8.2 | 1.2 | 8.6 | 1.2 | 9.7 | 1.2 | 11.0 | 1.5 | 12.9 | 1.5 | 14.1 | 1.5 | 18.1 |
5 | 1.2 | 8.9 | 1.2 | 9.3 | 1.2 | 10.5 | 1.5 | 12.7 | 1.5 | 14.0 | 1.5 | 15.4 | 1.7 | 20.2 |
7 | 1.2 | 9.5 | 1.2 | 10.0 | 1.2 | 11.3 | 1.5 | 13.7 | 1.5 | 15.2 | 1.5 | 16.7 | 1.7 | 22.0 |
8 | 1.2 | 10.2 | 1.2 | 10.7 | 1.5 | 12.7 | 1.5 | 14.7 | 1.5 | 16.3 | 1.7 | 18.4 | 1.7 | 23.7 |
10 | 1.2 | 11.7 | 1.5 | 13.0 | 1.5 | 14.7 | 1.5 | 17.1 | 1.7 | 19.4 | 1.7 | 21.0 | 1.7 | 28.0 |
12 | 1.5 | 12.0 | 1.5 | 13.3 | 1.5 | 15.1 | 1.5 | 17.6 | 1.7 | 20.1 | 1.7 | 24.0 | ||
14 | 1.5 | 13.2 | 1.5 | 13.9 | 1.5 | 15.8 | 1.5 | 18.5 | 1.7 | 21.0 | 1.7 | 25.1 | ||
16 | 1.5 | 13.8 | 1.5 | 14.6 | 1.5 | 16.6 | 1.7 | 19.8 | ||||||
19 | 1.5 | 14.5 | 1.5 | 15.3 | 1.5 | 17.5 | 1.7 | 20.9 | ||||||
24 | 1.5 | 16.6 | 1.5 | 17.6 | 1.7 | 20.6 | 1.7 | 24.2 | ||||||
27 | 1.5 | 17.0 | 1.5 | 18.0 | 1.7 | 21.0 | 1.7 | 24.7 | ||||||
30 | 1.5 | 17.5 | 1.7 | 19.0 | 1.7 | 21.8 | 1.7 | 25.6 | ||||||
37 | 1.7 | 19.2 | 1.7 | 20.3 | 1.7 | 23.4 | 1.7 | 27.6 | ||||||
44 | 1.7 | 21.4 | 1.7 | 22.5 | 1.7 | 26.2 | 2.0 | 31.6 | ||||||
48 | 1.7 | 21.9 | 1.7 | 23.2 | 1.7 | 26.9 | 2.0 | 32.2 | ||||||
52 | 1.7 | 22.5 | 1.7 | 23.0 | 1.7 | 27.8 | 2.0 | 33.0 | ||||||
61 | 1.7 | 23.7 | 1.7 | 25.2 | 2.0 | 29.4 | 2.2 | 35.2 | an |
5,Type,designation and application
Type | Designation | Application | |
Cu | Al | ||
YJV | YJLV | XLPE insulated PVC sheathed power cable | Suitable for indoor, channels, conduits. Unable to bear mechanical stress. |
YJY | YJLY | XLPE insulated PE sheathed power cable | |
YJV22 | YJLV22 | XLPE insulated steel-tape armored PVC sheathed power cable | Suitable for under ground, can bear mechanical stress, but can not endure large pulling force. |
YJV23 | YJLV23 | XLPE insulated steel-tape armored PE sheathed power cable | |
YJV32 | YJLV32 | XLPE insulated fine steel-wire armored PVC sheathed power cable | Can be installed in vertical well, and bear large mechanical pulling force. |
YJV42 | YJLV42 | XLPE insulated steel-wire armored PVC sheathed power cable | |
YJV33 | YJLV33 | XLPE insulated fine steel-wire armored PE sheathed power cable | |
YJV43 | YJLV43 | XLPE insulated steel-wire armored PE sheathed power cable |
Note: a,Single core cable armored material is non magnetic material.
b,our company can produce flame-retardant, fire-resistant, anti-termite, LSZH, small smoke and low halogen cables according to customer's requirements.
1. Flame-retardant power cable: add "ZRA-, ZRB-, and ZRC-"before above model no. 2. Fire-resistant power cable: add "NH-"before above model no. 3. LSZH power cable: add "DWZR-"before above model no. 4. Small smoke and low halogen power cable: add "DDZR-"before above model no.