Halogen-Free Low-Smoke Flame-Retardant cable(cable,power cable,halogen free cable)
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Halogen-Free Low-Smoke Flame-Retardant cable(cable,power cable,halogen free cable)
Nominal sectional area mm2 | Conductor No/Dia. mm | Nominal Insulated thick mm | Max overall Dia. mm | Condcutor Resistance at 20 | Min insulated resistance at 70MΩ/km | Weight Kg/km | ||
Cu | Al | Cu | Al | |||||
1.5 | 1/1.38 | 0.7 | 3.3 | 12.1 | - | 0.011 | 19.2 | - |
1.5 | 7/0.52 | 0.7 | 3.5 | 12.1 | - | 0.010 | 20.6 | - |
2.5 | 1/1.78 | 0.8 | 3.9 | 7.41 | 11.8 | 0.010 | 30.8 | 15.0 |
4 | 1/2.25 | 0.8 | 4.4 | 4.61 | 7.39 | 0.0085 | 45.5 | 21.0 |
6 | 1/2.76 | 0.8 | 4.9 | 3.08 | 4.91 | 0.0070 | 65.0 | 29.0 |
10 | 7/1.35 | 1.0 | 7.0 | 1.83 | 3.08 | 0.0065 | 110.0 | 52.0 |
16 | 7/1.70 | 1.0 | 8.0 | 1.15 | 1.91 | 0.0050 | 170.0 | 70.0 |
25 | 7/2.14 | 1.2 | 10.0 | 0.727 | 1.20 | 0.0050 | 270.0 | 110.0 |
35 | 7/2.52 | 1.2 | 11.5 | 0.524 | 0.868 | 0.0040 | 364.0 | 150.0 |
50 | 19/1.78 | 1.4 | 13.0 | 0.387 | 0.641 | 0.0045 | 500.0 | 200.0 |
70 | 19/2.14 | 1.4 | 15.0 | 0.268 | 0.443 | 0.0035 | 688.0 | 269.0 |
95 | 19/2.52 | 1.6 | 17.5 | 0.193 | 0.320 | 0.0035 | 953.0 | 360.0 |
120 | 37/2.03 | 1.6 | 19.0 | 0.153 | 0.253 | 0.0032 | 1168.0 | 449.0 |
150 | 37/2.25 | 1.8 | 21.0 | 0.124 | 0.206 | 0.0032 | 1466.0 | 551.0 |
185 | 37/2.52 | 2.0 | 32.5 | 0.099 | 0.164 | 0.0032 | 1808.0 | 668.0 |
Electric Cables:
CU Conductor PVC Insulated PVC Sheathed Power Cable
1. The applications: Rated voltage (U0/U) 0.6/1kv 8.7/15KV 26/35kV in transmission & transformation line & for water-proofing purpose .
2. Standards: 60502IEC ISO9001
3. Product features:
1) No necessary to heat up in advance while installing above 0oC.
2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).
3) Max. Permissible temperature at short circuit (5s. at longest): 250oC.
4) Permissible bending radius:
Single core: ≥20(d+D)±5%.
Three-core:≥15(d+D)±5%(D is the actual overall diameter of cable, and d is the actual overall diameter of conductor).
Detailed Description
Our company can produce both flame retardant and non-flame retardant series of XLPE power cable.. Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards stated above..
The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cable according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on..
Nominal sectional area mm2 | Conductor No/Dia. mm | Nominal Insulated thick mm | Max overall Dia. mm | Condcutor Resistance at 20 | Min insulated resistance at 70MΩ/km | Weight Kg/km |
2.5 | 9/0.41 | 0.8 | 4.2 | 7.41 | 0.011 | 33.0 |
4 | 19/0.52 | 0.8 | 4.8 | 4.61 | 0.009 | 48.0 |
6 | 19/0.64 | 0.8 | 5.6 | 3.08 | 0.0084 | 68.0 |
10 | 49/0.52 | 1.0 | 7.6 | 1.83 | 0.0072 | 115.0 |
16 | 49/0.64 | 1.0 | 8.8 | 1.15 | 0.0062 | 176.0 |
25 | 98/0.58 | 1.2 | 11.0 | 0.727 | 0.0058 | 272.0 |
35 | 133/0.58 | 1.2 | 12.5 | 0.524 | 0.0052 | 384.0 |
50 | 133/0.68 | 1.4 | 16.5 | 0.387 | 0.0051 | 510.0 |
70 | 189/0.68 | 1.4 | 16.5 | 0.268 | 0.0045 | 714.0 |
95 | 259/0.68 | 1. | 19.5 | 0.139 | 0.0035 | 965.0 |
120 | 259/0.76 | 1.8 | 22.0 | 0.153 | 0.0032 | 1210.0 |
150 | 259/0.85 | 1.8 | 25.0 | 0.124 | 0.0032 | 1510.0 |
We also produce:
flame-retardant control cable, XLPE insulated control cable, XLPE insulated flame-retardant control cable, low smoke halogen free flame-retardant control cable etc.
1, Rated voltage Uo/U includes 0.6/1kV, 1.8/3kV, 3.6/6kV, 6/6kV, 6/10kV, 8.7/10kV, 8.7/15kV,12/20kV, 12/20kV, 21/35kV, 26/35kV;
2, The permitted highest operating temperature of conductor for long-term working is 90°C .In short-circult (Max.long-term time is no more than 5 seconds) ,the highest temperature of conductor is not higher than250°C;
3, D.C. Conductor resistance complies with the stipulations of GB/T3956;0
4, PVC sheath cable Environment temperature in laying the cable should be no lower than 0 ;PE sheath cable Environment temperature in laying the cable should be no lower than -20 ; The Min. bending radius should be no less than 15 times of cable outer diameter;
5, The cable is laid without drop limit;
6, Working Frequency Voltage Test: for cable with UO of 1.8kV or lower: 2.5 UO+ 2kV/5 min without puncture for cable with UO of 3.6kV or higher: 3.5 UO / 5 min without puncture
7, Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73UO for the cable with of 3.6kV or higher.
Instruction
1) No necessary to heat up in advance while installing above 0oC.
2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).
3) Its structure is simple and using conveniently, also can be laid with no restriction of different level.
4)The long term operating temperature is 90, and its transmit capacitance is large.
5) When using it, please check the wire insulation from the appearance in case of causing any damage because of transporting or storing not well, and influence its effect.