Marine XLPE Insulation Polyolefin Sheathed Flame-retardant Control Cable
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Marine XLPE Insulation Polyolefin Sheathed Flame-retardant Control Cable
Applications
The shipboard control cables are intended for control system on shipboard and offshore building.
Type | Name |
CKJPF/DA/SA | XLPE insulated,PF sheathed, flame retardant, shipboards control cable |
CKJPF80/DA/SA | XLPE insulated, PF inner sheathed, copper wire braided, armored, flame retardant, shipboard control cable |
CJPF90/DA/SA | XLPE insulated, PF inner sheathed, steel wire braided, armored, flame retardant, shipboard control cable |
CKJ82/DA/SA | XLPE insulated, copper wire braided, armored(over-all shield), PVC outer sheathed, flame retardant, shipboard control cable |
CKJ92/DA/SA | XLPE insulated, PF inner sheathed, copper wire braided, armored, PVC outer sheathed, flame retardant, shipboard control cable |
CKJPF82/DA/SA | XLPE insulated, PF inner sheathed, steel wire braided, armored, PVCouter sheathed, flame retardant, shipboard control cable |
CKJPF92/DA/SA | XPLE insulated, PF sheathed, flame retardant, fire resistant, shipboard control cable |
CKJPF/NA/CKJPF80/NA | XLPE insulated, PF inner sheathed, copper wire braided, armored(over all shield), flame retardant, fire resistant, shipboard control cable |
Specification
cores * cross section mm2 | diameter mm | weight kg/km | |
CKJPF/80 | CKJPF/90 | ||
2×0.75 | 11.5 | 105 | 102 |
4×0.75 | 12.5 | 144 | 140 |
7×0.75 | 15 | 227 | 221 |
10×0.75 | 18.5 | 312 | 305 |
14×0.75 | 19.5 | 372 | 365 |
19×0.75 | 21.5 | 450 | 442 |
24×0.75 | 25 | 434 | 554 |
30×0.75 | 26 | 647 | 637 |
37×0.75 | 28 | 746 | 735 |
2×1.0 | 11.5 | 114 | 112 |
4×1.0 | 13 | 160 | 157 |
7×1.0 | 15.5 | 254 | 235 |
10×1.0 | 19 | 336 | 328 |
14×1.0 | 20.5 | 423 | 425 |
19×1.0 | 22 | 518 | 510 |
24×1.0 | 26 | 640 | 630 |
30×1.0 | 27 | 742 | 732 |
37×1.0 | 29 | 874 | 864 |
1, Rated voltage Uo/U includes 0.6/1kV, 1.8/3kV, 3.6/6kV, 6/6kV, 6/10kV, 8.7/10kV, 8.7/15kV,12/20kV, 12/20kV, 21/35kV, 26/35kV;
2, The permitted highest operating temperature of conductor for long-term working is 90°C .In short-circult (Max.long-term time is no more than 5 seconds) ,the highest temperature of conductor is not higher than250°C;
3, D.C. Conductor resistance complies with the stipulations of GB/T3956;0
4, PVC sheath cable Environment temperature in laying the cable should be no lower than 0 ;PE sheath cable Environment temperature in laying the cable should be no lower than -20 ; The Min. bending radius should be no less than 15 times of cable outer diameter;
5, The cable is laid without drop limit;
6, Working Frequency Voltage Test: for cable with UO of 1.8kV or lower: 2.5 UO+ 2kV/5 min without puncture for cable with UO of 3.6kV or higher: 3.5 UO / 5 min without puncture
7, Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73UO for the cable with of 3.6kV or higher.
Instruction
1) No necessary to heat up in advance while installing above 0oC.
2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).
3) Its structure is simple and using conveniently, also can be laid with no restriction of different level.
4)The long term operating temperature is 90, and its transmit capacitance is large.
5) When using it, please check the wire insulation from the appearance in case of causing any damage because of transporting or storing not well, and influence its effect.