PVC/PVC non-shielded flexible control cable
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
PVC/PVC non-shielded flexible control cable
mechanical control cable, PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable
specification:
1. executive standard: GB/T 9330-2008
2. rated alternating voltage≤ 450/750
3. prodlucts usage features:
(1) the long-time permissible operation temperature of conductor shall not be high than 70 centigrade degree.
(2) Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than160
centigrade degree.
(3) The power cable is not limited by drop in level when being laid, and the ambient temperature shall not
be lower than 0 centigrade degree.
(4) Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents and flame
(5) Light weight, perfect bending properties, installed an maintained easily and convenient
Standard: GB9330-88
1. The Control Cable products can be produced according to the standard GB/T9330-2008, and Control Cables are suitable for the connection of controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
2. Type of Control Cable: KVV Control Cable, KVVP, KVVP2, KVV22, KVV32, KVVR, KVVRP, KYJVP, Control Cable.
3. Service Conditions
(1)The long-time working temperature of conductor of PVC insulated cable is 70oC
(2)The temperature for laying the cables can't be lower than 0oC. Permissible bending radius(3): Unarmoured cable: R≥ 6D; (D: Outer diameter of the cable); Armoured or copper-tape screened cable: R≥ 12D; Shielded flexible cable: R≥ 6D
TYPE | NAME | Section Area(mm 2 ) |
|
| |||||
| 0.75 | 1 | 1.5 | 2.5 | 4 | 6 | 10 |
| |
| No. of Core | Application Site | |||||||
KVV | Copper Conductor, PVC Insulated and Sheathed Control Cable | 2-48 | 2-14 | 2-10 | Permanent installation indoors, in cable ditches or pipes | ||||
ZR-KVV | Flame Retardant Copper Conductor, PVC Insulated and Sheathed Control Cable | ||||||||
NH-KVV | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed Control Cable | ||||||||
KVVP | Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable | 2-48 | 2-14 | 2-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required | ||||
ZR-KVVP | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable | ||||||||
NH-KVVP | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding Shielded Control Cable | ||||||||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 4-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required | ||||
ZR-KVVP2 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | ||||||||
NH-KVVP2 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | ||||||||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable | 7-48 | 4-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches, directly buried, Be able to withstand stronger external mechanical force | |||
ZR-KVV22 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable | ||||||||
NH-KVV22 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Steel tape Armored Control Cable | ||||||||
KVV32 | Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | 19-61 | 7-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches, vertical shaft Be able to withstand stronger external mechanical force | |||
ZR-KVV32 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | ||||||||
NH-KVV32 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | ||||||||
KVVR | Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | 4-48 | - | - | Installation indoors where flexibility and movability are required | ||||
ZR-KVVR | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | ||||||||
NH-KVVR | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Flexible Control Cable | ||||||||
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | 4-16 | 4-48 | - | - | Installation indoors where flexibility shielding and movability are required | |||
ZR-KVVRP | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | ||||||||
NH-KVVRP | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |