MCP DQ1102D - Dual channel Digital Storage Oscilloscope / Mixed Signal Oscilloscope with logic analyzer
Negotiable /Piece
Min.Order:2 Pieces
DQ1102D - Digital Storage Oscilloscope / Mixed Signal Oscilloscope
Features:
.Support logic analyzer and oscilloscope
.1GSa/s sampling rate and 50GSa/s equivalent sampling rate
.1024k recording length
.7″wide screen 64k color TFT display
.USB-host for save and update
Technical Data | DQ1062D | DQ1102D | DQ1202D |
Channels | 2 channels oscilloscope+ 16 channels logical analyser | ||
Sampling rate | 1GSa/s | ||
Equivalent sampling rate | 25GSa/s | ||
Display | |||
Type | 7″wide screen 64k color TFT LCD | ||
Display contrast | Adjustable (16 gears) with the progress bar | ||
Display resolution | 800 horizontal × 480 vertical pixels | ||
Vertical system | |||
Sensitivity and accuracy | 2mV/div~5V/div | ||
Vertical resolution | 8 bit | ||
Width of band (-3dB) | DC (AC 10Hz) ~ 60MHz | DC (AC 10Hz) ~ 100MHz | DC (AC 10Hz) ~ 200MHz |
Selectable analog bandwidth limit | 20MHz | ||
Rise time | ≤5.8ns | ≤3.5ns | ≤1.8ns |
DC gain Accuracy | ±4%(2mV/div~5mV/div) ±3%(10mV/div~5V/div) | ||
DC measurement accuracy | ±(3%Rdg.+0.1div+1mV)(10mV/div~5V) ±(3%(Rdg.+vertical position)+0.2div+1%(vertical position) (2mV/div~200mV/div, +2mV; 200mV/div~5V/div, +50mV) | ||
Horizontal system | |||
SEC/DIV range | 2ns~40s/div, at 2-4-8 increment | ||
Waveform interpolation | Sin(x)/x | ||
Recording length | 1024k | ||
Sampling rate and delay time accuracy | ±50ppm (any time interval 1ms) | ||
Delta time measurement accuracy | Single: ±(1 sampling time interval + 100ppm×Rdg. + 0.6ns) | ||
Average values: ± (1 sampling time interval + 100ppm×Rdg. + 0.4ns) | |||
Trigger system | |||
Mode | Auto, normal, single | ||
Type | Edge, pulse, video, alternate | ||
Hold off range | 100ns~10s | ||
Math | +, -, x, ÷ | ||
FFT | |||
Acquire input | |||
Input coupling | DC, GND, AC | ||
Input impedance | 1MΩ ±2% 20pF±3pF | ||
Probe attenuation | 1x, 10x, 100x, 1000x | ||
Max. input voltage | 300V (DC+AC peak) | ||
Measurement | |||
Cursor | Voltage difference ( V) between cursors Time difference ( T) between cursors Reciprocal of T in Hz (1/ T) | ||
Auto-measure | Vrms, Vavg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp; Period, Freq, Rise, Fall, +Width, -Width, +Duty, -Duty, Delay | ||
I/O | |||
Standard | USB(D), USB(H) | ||
Options | LAN | ||
Calibrator | |||
Output voltage | 5V≥( 1MΩ load) | ||
Output frequency | 1kHz | ||
Logical analyzer | |||
Input channel | D0~D15 | ||
Max. input impedance | 200k (C=10P) | ||
Max. sampling rate | 500MHz | ||
Recording length | 512k | ||
Max. input voltage | ±60V | ||
Minimum voltage slew | 1.2Vpp | ||
Logic threshold range | ±8V | ||
Compatible input | TTL, CMOS, ECL | ||
Cursors | Voltage difference (ΔV) between cursors Time difference (ΔT) between cursors Reciprocal of ΔT in Hz (1/ΔT) | ||
Measurement | Period and Frequency | ||
Record postion | RefA, RefB | ||
Trigger mode | Edge | D0~D15 select slope (rising or falling edge) | |
Pulse width | D0~D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, | ||
Code-type | D0~D15 select code-type (H, L, X) | ||
Duration | D0~D15 select persist time and trigger when (data terminate, data start, and data delay) | ||
Queue | D0~D15 select specific data index (0~3) and code-type (H, L, X) | ||
Repeat | D0~D15 select code-type (H, L, X) and repeat times | ||
Power source | 100~120VACrms (±10%), 45~440Hz; 30VA Max; CAT Ⅱ 120~240VACrms(±10%), 45~66Hz; 30VA Max; CAT Ⅱ | ||
Dimensions (Wx Hx D) | 315×142×110mm | ||
Weight | 2.1kg | ||
Accessories | Operation manual, power cord, USB cable, probe×2, sofrware CD-ROM, logic analyzer probe |