DQ8104 - 4 channel DIGITAL STORAGE OSCILLOSCOPE/ oscilloscope 4-channel/oscilloscope 4ch
Negotiable /Piece
Min.Order:1 Piece
DQ8000 - DIGITAL STORAGE OSCILLOSCOPE
Features
.4 channel oscilloscope
.2GSa/s sampling rate and 50GSa/s equivalent
sampling rate
.1024k recording length
.5.7¡åcolor LCD display
.USB-host/device, RS232 and option LAN,
GPIB interface
Technical Data | DQ8104 | DQ8204 | DQ8304 | ||
Sampling rate | 2G Sa/s (4 channels total) | ||||
Equivalent sampling rate | 25G Sa/s | 50G Sa/s | 50G Sa/s | ||
Display | |||||
Type | 5.7" rectangle color LCD | ||||
Backlight intensity | 300 ni | ||||
Display resolution | 320 horizontal x 240 vertical pixels | ||||
Vertical system | |||||
Sensitivity and accuracy | 2mV/div~5V/div | ||||
Vertical resolution | 8 bit | ||||
Width of band (-3dB) | DC (AC5Hz) 0~100MHz | DC (AC5Hz) 0~200MHz | DC (AC5Hz) 0~300MHz | ||
Selectable analog bandwidth limit | 100MHz | ||||
Rise time | ≤3.5ns | ≤1.8ns | ≤1.2ns | ||
DC gain Accuracy | ±4%(2mV/div), ±3%(5mV/div~5V/div) | ||||
DC measurement accuracy | ±(3%+0.1div)(2mV/div), ±(3%+0.1div)(5mV/div~5V/div) | ||||
Voltage different (Δt) measurement accuracy | ±(3%+0.05div) | ||||
Horizontal system | |||||
SEC/DIV range | 5ns~50ns/div), at 1-2-5 increment | ||||
Waveform interpolation | Sin(x)/x | ||||
Recording length | 1024k | ||||
Storage depth | 24k(Max.) | ||||
Equivalent storage depth (Dual time base) | 60M | ||||
Sampling rate and delay time accuracy | ± 50ppm (any time interval ≥ 1ms) | ||||
Delta time measurement accuracy | Single: ± (1 sampling time interval + 50ppm x rdg. + 0.6ns) Average values: ± (1 sampling time interval + 50ppm x rdg. + 0.4ns) | ||||
Trigger system | |||||
Mode | Auto, normal, single | ||||
Type | Edge, pulse, video, alternate | ||||
Hold off range | 96ns~1.5s | ||||
Math | +, -, x, ÷ | ||||
FFT | |||||
Acquire input | |||||
Input coupling | DC, GND, AC | ||||
Input impedance | 1MΩ±2% 16pF±3pF | ||||
Probe attenuation | 1x, 10x, 100x, 1000x | ||||
Max. input voltage | 400V (DC+AC peak) | ||||
Measurement | |||||
Cursor | Voltage difference (V) between cursors Time difference (T) between cursors Reciprocal of T in Hz (1/T) | ||||
Auto-measure | Vrms, Vavg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp; Period, Freq, Rise, Fall, +Width, -Width, +Duty, -Duty, Delay | ||||
Saving waveforms | 10 groups of waveforms and 10 setups | ||||
I/O | |||||
Standard | USB(D), USB(H) | ||||
Options | GPIB, LAN | ||||
Calibrator | |||||
Output voltage | 3V≥( 1MΩ load) | ||||
Output frequency | 1kHz | ||||
Digital multimeter characterizes | |||||
DC voltage | Range | 400.0mV/4.000V/40.00V/400.0V | |||
Accuracy | ±(1%+5digits) | ||||
AC voltage (40Hz~400Hz) | Range | 400.0mV/4.000V/40.00V/400.0V | |||
Accuracy | ±(1.2%+5digits) | ||||
Resistance | Range | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | |||
Accuracy | ±(1.5%+5digits) | ||||
On/off | <70.0Ω | ||||
Diode | Forward voltage drop 0.5~0.8V | ||||
DC current | Range | 4mA/40mA/400mA | |||
Accuracy | ±(1%+5digits) | ||||
Range | 4A | ||||
Accuracy | ±(1.5%+5digits) | ||||
Power source | 100~240VACrms, 45~440Hz; 50VA Max; CAT II | ||||
Dimensions (W x H x D) | 336mm x 117mm x 174mm | ||||
Weight | 3.8kg | ||||
Accessories | Operation manual, adapter, probex 2, multimeter penx2, current-voltage convertor modulex 2 |