Dmax-B Series Rapid Steam Sterilizer
Negotiable /Set
Min.Order:1 Set
SHINVA Medical Instrument Co., Ltd. (Shandong)
LMQ.CV Series Vacuum Autoclave is a kind of high speed automatic autoclave which can sterilize wrapped and unwrapped instruments, textiles, rubber, glass utensils, etc. It is a good choice for stomatology, ophthalmonogy, operating room and CSSD.
Main features
Micro-computer control, touch button, LCD display and powerful man-machine conversation function
Fully automatic for process of water filling, pulse vacuum, heating, sterilization, vacuum drying, exhaust etc. Automatically display error information
Various programs such as instrument, textile, rubber, liquid, culture medium and user-defined can be chosen
To exhaust cooling air, exhaust cooling air thoroughly and ensure steam saturation
Quick exhaust and slow exhaust automatic control can avoid overflow for liquid sterilization
Buzzer alarms when sterilization finished
Function of pre-heating control and delay start
0.22µm high efficiency air filter ensures the air sterile and avoid polluted again
B-D test and vacuum test program
Holding temperature function; user can get articles randomly in this process
Built-in water rank, steam and water internal circulation make it easy for water tank cleaning
Level sliding door, self-bulge sealed gasket. Operate easily and safety
Post pulse-vacuum drying system; after drying, the residual humidity for appliances is no more than 0.2%, and that for dressing, 1%
Safety devices
Over heating protection; system will cut off power automatically and send alarm if chamber temperature is over heating
Door detecting device; system will cut off the power if door opened during autoclave running
Burned protection; system will cut off power automatically, display error and send alarm if water level is too low
Door interlock device; it will start only after the door is closed completely; door cannot be opened if there is pressure in chamber
Automatic safety device; alternating current major loop has short circuit device, direct current loop has overvoltage protection
Detecting and indicating function for sensor disconnection
Technical parameters
Design pressure: -0.1/0.28Mpa
Range of sterilization time: 105~136°C
Design temperature: 150°C
Dissolve temperature: 60~100°C
Maximum working pressure: 0.23Mpa
Holding temperature: 40~60°C
Range of pressure display: -0.1~0.3Mpa
Time set range: 0~99 hours
Vacuum degree: ≤80Kpa
Chamber: SUS304 stainless steel
Accuracy of temperature display: 0.1°C
Accessories: two stainless steel sterile baskets
Model | Code | Chamber Dimension | Capacity | Power | Weight |
LMQ.CV | 4060 | 400×640mm | 80L | 380v 50Hz 4.5Kw | 100KG |
The product information will probably be updated without notice, if that happens, please refer to the latest technical material.