CE, ISO passed, TMQ.C-5090 Autoclave

CE, ISO passed, TMQ.C-5090 Autoclave

Negotiable /Unit

Min.Order:1 Unit

Supply Ability:
50 Unit / Units per Month
Port:
qingdao
Payment Terms:
T/T

Quick Details View All >

Type:
Pressure Steam Sterilization Equipments
Brand Name:
shinva
Model Number:
TMQ.Cv5070
Place of Origin:
Shandong, China

SHINVA Medical Instrument Co., Ltd. (Shandong)

Business Type: Manufacturer,Trading Company
Zibo Shandong China
Main Products: pulse vacuum steam sterilizer ,radiotherapy equipment ,low temperature plasma sterilizer ,ultrasonic washer ,diagnostic equipment

Product Details

Specifications

Steam and water circulation system, no external water source, not exhaust steam outside, environment is clean and dryness.

Major capability and characteristics :

Micro-computer control, touch-key.
Automatic control over the processes of heating, sterilization, steam exhaust, filling water and dryness Process, temperature, time dynamic LCD displayed.
Positive pressure pulse function exhaust cool air of sterilizing chamber thoroughly and ensure the steam saturation.
Steam and water circulation system, no external water source, not exhaust steam outside, environment is clean and dryness.
There are equipped with instrument, instrument bags, dressing, rubber sterilization programs for customers choice.
Self-failure test system capable of displaying failure on the LCD.
Printer is available for optional.
The buzzer alarms when a cycle of operation is completed.

Safety devices:

Auto protection device against over temperatureThis system cuts off power automatically if the designed temperature is surpassed.
Door safety interlockThe door cannot be opened until there is no pressure in the chamber and power for heating cannot be switched on until the door is firmly closed.
Safety valve of auto release against overpressureIt opens when the designed pressure is surpassed.
The program will be stopped if water level lower than the low limit, alarm with sound and light.
Electronic circuits safety device: direct current control loop and has protection against overload and voltage surpassed, alternating current main loop has short-circuit protection device.

Main technical parameters:

Designed pressure: 0.26Mpa
Designed temperature: 150
Rated working pressure: 0.22Mpa
Sterilization temperature: 105~136

Precision of temperature displayed: 0.1
Temperature degree of uniformity: ≤±0.5
Material of chamber: SUS 304 stainless steel

Capacity:185L

 

Contact Supplier

Mr. Oliver Lee Administrator Chat Now
Telephone
0086-533-77777777
Mobile
0086-18265888198
Fax
86-533-3583253
Address
No. 7 Taimei Road, Zibo New & Hi-tech Zone, Shandong, P.R.CHINA Zibo,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Sterilization Equipments
Categories
Hi~