HBsAg ELISA Kit

HBsAg ELISA Kit

Negotiable /Box

Min.Order:1 Box

Supply Ability:
10000 Box / Boxes per Month
Port:
Beijing or Tianjin
Payment Terms:
T/T Credit Card

Quick Details View All >

Type:
Blood Testing Equipments
Brand Name:
Bioneovan
Place of Origin:
Beijing, China
Model Number:
ELISA

Bioneovan Co., Ltd.

Business Type: Manufacturer,Trading Company
Beijing China
Main Products: ELISA Test ,Rapid Test ,Hepatitis Tests ,TOTA Test ,TORCH-IMG-Test

Product Details

Specifications

HBsAg ELISA is used for the qualitative determination of Hepatitis B surface antigen (HBsAg) in human serum or plasma. This test

HBsAg ELISA Kit

Catalog No.:BE101A

Enzyme-linked immunosorbent assay for the detection of HBsAg in serum or plasma                                                                                              

INTRODUCTION

HBsAg ELISA is used for the qualitative determination of Hepatitis B surface antigen (HBsAg) in human serum or plasma. This test is indicated for the screening of blood and blood products to be used for transfusion and an aid for the diagnosis of existing or previous hepatitis B infection.

 

SUMMARY AND PRINCIPLE OF THE TEST

 

Hepatitis B is an infectious illness caused by hepatitis B virus (HBV) which infects the liver of hominoidea, including humans, and causes an inflammationcalled hepatitis. HBV is excreted in body fluids such as semen, saliva, blood and urine in persons with acute or chronic infection. The hepatitis B virus is known as a blood-borne virus because it is transmitted from one person to another via blood or fluids contaminated with blood.

 

About 7.18% carry hepatitis B Virus surface antigen. About 93 million people are chronic carriers of HBV among which about 30 million are suffering Hepatitis B around the country. Transmission of hepatitis B virus results from exposure to infectious blood or body fluids.

 

When HBV invades the body it causes liver damage through induction of auto-immunity. Three immunity has been found, surface antigen (HBsAg)/HBsAb, core antigen (HBcAg)/HBcAb and e antigen(HBeAg)/HBeAb. As it is difficult to detect the core antigen in the serum, the other five are been done to diagnosing HBV. The surface antigen contains the determinant “a”, common to all known viral subtypes and immunologically distinguished in two distinct subgroups (ay and ad). HBV has 10 major serotypes and four HBsAg subtypes have been recognized (adw, ady, ayw, and ayr). HBsAg can be detected 2 to 4 weeks before the ALT levels become abnormal and 3 to 5 weeks before symptoms develop. The serological detection of HBsAg is a powerful method for the diagnosis and prevention of HBV infection and ELISA has become an extensively used analytical system for screening of blood donors and clinical diagnosis of HBV in infected individuals

 

PRINCIPLE OF THE ASSAY

 

The HBsAg EIA is a solid-phase simultaneous sandwich immunoassay, which employs monoclonal antibodies and polyclonal antibodies specific for HBsAg. Microtiter well is coated with monoclonal antibodies specific for HBsAg. A serum specimen is added to the antibody coated Microtiter wells together with enzyme conjugated polyclonal antibodies. HBsAg, if present, will form an antibody-HBsAg-antibody-enzyme complex. The plate is then washed to remove unbound material. Finally, a solution of substrate is added to the wells and incubated. A blue color will develop in proportion to the amount of HBsAg present in the specimen. The enzyme-substrate reaction can be stopped and the result is visualized by naked eye or read by EIA plate reader for absorbance at the wavelength of 450 nm(450 nm/630 nm) and is proportional to the amount of antibodies present in the specimen..

 

REAGENTS

 

Materials provided with the kits:

Item

Description

96T

480T

1

Coating Plate

1

5

2

Negative Control

0.5ml

2.5ml

3

Positive Control

0.5ml

2.5ml

4

Enzyme Conjugate

6ml

30ml

5

Wash Buffer Concentrate (20x)

20ml

100ml

6

Substrate Solution A

6ml

30ml

7

Substrate Solution B

6ml

30ml

8

Stop Solution

6ml

30ml

9

Plastic Bag

1

5

10

Seal Paper

3

15

11

Manual

1 copy

5 copy

 

Materials required but not provided:

  1. Precision pipettes: 0.02, 0.05, 0.10, 0.15, 0.20, and 1.0 ml.
  2. Disposable pipette tips.
  3. Distilled water.
  4. HumidifiedBox capable of maintaining 37°C
  5. Absorbent paper or paper towel.
  6. Microtiter plate or strip-well washer
  7. Microtiter plate reader with 450nm (or 450 nm/630 nm)wavelength
  8. Timer

 

SPECIMEN COLLECTION AND PREPARATION

 

Serum should be prepared from a whole blood specimen obtained by acceptable medical techniques. Either serum or plasma can be used in this test. Remove serum or plasma from the clot or blood cells as soon as possible to avoid hemolysis. Specimen with extensive particulate should be clarified by centrifugation prior to use. Specimen frozen at -20°C or colder may be used. Avoid repeated freeze thaw.

 

PRECAUTIONS FOR USERS

 

  1. For in-vitro diagnostic use only.
  2. Do not use kit beyond expiration date.
  3. Do not mix components from kits with different lot number.
  4. Avoid microbial contamination of reagents.
  5. Do not pipet reagent by mouth and no smoking or eating while performing assays.
  6. Wear gloves during the whole process and avoid reagents or specimen spilling-out.
  7. Wipe up the spills using 5% hypochlorite solution.
  8. Decontaminate all liquids or solid wastes before deposing.

 

STORAGE OF TEST KITS

 

Unopened test kits should be stored at 2-8°C. DO NOT FREEZE KIT COMPONNETS. The microtiter plate should be kept in a sealed bag to minimize exposure to damp air. Use up the reagents as soon as possible after the kit is unpacked.

 

WORKING WASH BUFFER

 

Dilute the 20X wash buffer concentrate with deionized or distilled water 1:20. For example, 5 ml of wash buffer concentrate should be diluted to a total volume of 100 mL with deionized or distilled water.

 

ASSAY PROCEDURE:

  

It is strongly advised to analyze each specimen and controls in duplicate. All the reagents should equilibrate to room temperature before use.

  1. Dispense one drop (100μl) of Positive Control as well as Negative Control in duplicate into respective wells. Set one blank well as background control, and 100ul of serum or plasma samples into respective test wells.
  2. Place the microtiter plates into a humidified box, and incubate at 37°C for 60 minutes.
  3. Add one drop (50μl) of Enzyme Conjugate to each well. Mix it gently by swirling the microtiter plate on flat bench for 1 minute. Do not add Enzyme Conjugate to the blank well.
  4. Place the microtiter plates into a humidified box, and incubate at 37°C for 30 minutes.
  5. Wash each well 5 times by filling each well with diluted wash buffer, then inverting the plate vigorously to get all water out and blocking the rim of wells on absorbent paper for a few seconds.
  6. Add one drop (50μl) of Substrate Solution A (HRP-substrate) to each well, then add one drop (50μl) of Substrate Solution B (TMB) to each well. Mix gently and incubate at 37°C for 30minutes.

 

 

 

 

Contact Supplier

Mr. Steven Tan General manager Chat Now
Telephone
86-010-69255832
Mobile
18600464506
Fax
86-010-60216761
Address
NO.18, Keyuan Road, DaXing Economic Development Zone, Beijing,China Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > General Assay & Diagnostic Apparatus
Categories
Hi~