New SF6 high-precision gas leak detector DY-360
USD $2096 - $2236 /Set
Min.Order:1 Set
Wuhan Deya Power Technology Co., Ltd
1、 Product characteristics
1. The internationally advanced pump suction, NDIR single beam dual wavelength infrared measurement technology is adopted, with high detection sensitivity, accuracy and stability;
2. High precision digital processing technology and unique drift control and temperature compensation circuit are adopted, with strong anti-interference capability;
3. It has full function self checking functions such as low battery, sensor failure and over range during detection;
4. Color large screen dot matrix LCD display and full Chinese menu function management are adopted;
5. The detection process displays the detection data in real time and has a dynamic waveform curve analysis chart;
6. The lower limit of the alarm can be set, and the screen displays the alarm set value, using the audible and visual alarm mode;
7. Automatic calculation of leakage amount and leakage rate of the tested equipment;
8. Self calibration function;
9. Large capacity rechargeable lithium battery, with continuous working time more than 5 hours;
10. Clock perpetual calendar function;
11. Small size, convenient for hand-held measurement;
12. It has 100 data and waveform storage functions, numbering and browsing query functions;
13. High brightness LED light source, which can be used for flashlight lighting;
2.2 Technical indicators
2、 Technical parameters
project | content | |||
1 | Product model | DY-360 SF6 Gas leak detector | ||
2 | Measurement method | NDIR Single beam dual wavelength infrared measurement technology | ||
3 | Monitoring gas | measuring range | Resolution | accuracy |
Sulfur hexafluoride gas | 0~2000ppm | 0.1ppm | ±(3%+5d) | |
4 | Repetitive performance | <2% | ||
5 | Air pump extraction speed | 0.4L/min | ||
6 | Duration | Not less than 5 hours | ||
7 | Instrument start-up warm-up time | ≤3minute | ||
8 | Corresponding time | Less than 30 seconds | ||
9 | recovery time | Less than 30 seconds | ||
10 | Charging adapter specifications | DC12V/2A | ||
11 | Surge (impact) immunity | ±1.2kV | ||
12 | ambient temperature | -20℃~+50℃ | ||
13 | ambient humidity | Relative humidity 5~95% (non condensing) | ||
14 | atmospheric pressure | 50kPa~110kPa | ||
15 | Degree of protection | IP33, Double insulation, CAT II standard | ||
16 | Overall dimensions | 200mm wide × 240 deep mm × 80mm high | ||
17 | Main engine weight | 1KG |