CI547 CI570 3BSE001440R1 ABB Analog module processor
USD $100 - $200 /Pound
Min.Order:100 Pounds
Xiamen xiongba e-commerce Co., Ltd. Zhangzhou Branch
CI858K01 3BSE018135R1 ABB Dual rs232-c interface kit (available in stock)
CI861 3BSE058590R1 ABB CI861K01 Communication interface module
CI867AK01 3BSE092689R1 ABB New imported warehouse spot module
CI867K01 3BSE043660R1 ABB Communication interface kit (available in stock)
ABB new DCS module ci868k01-ea control system module 3bse048845r2 bargaining
CM572 CM572-DP CM572-DP-XC ABB AC500 PLC communication module
CI547 CI570 3BSE001440R1 ABB Analog module processor
CI547 CI570 3BSE001440R1 ABB Analog module processor
Our Email: 2235954483@qq.com
contact number:13313705507
contacts:HE
The GC module is comprised of three parts: columns, chromatographic valve and
GC module circuit board. The valve controls the flow of gas within the system. The
columns perform the separation of the gas into component parts for analysis. The
GC module circuit board contains the sensors for the carrier pressure regulators,
the sample pressure sensor and the thermal conductivity detectors (TCD's) which
detect the different gas components as they leave the GC columns. It also
contains an EEPROM or FLASH memory for storage of calibration and
characterization information of the module and its sensors.
Figure 1—10 shows the GC module with the oven wall removed.
The analytical processor board provides real-time system control and
measurement of the analytical processes within the NGC. It does this by
interfacing with all of the sensors in the GC module (and optional feed-through
temperature sensor) as well as controlling the carrier pressure regulator valves,
sample stream valves, the pilot valve and the heaters. The data generated by the
analytical processor is passed to the digital controller board via a high speed serial
interface.
The analytical processor also has two status LED's used for troubleshooting. The
red LED indicates that the board is powered on. If the board is remotely powered
down by the digital controller, or has no power, this LED is off. The yellow LED
indicates that the analytical processor's CPU has booted its program successfully
and is controlling its processes as directed by the digital controller. This LED
should be flashing at a high speed (between 20-40Hz). If this LED is off or is on
solid with no flashing, then the software in the analytical processor is not running
properly.
Figure 1—12 shows the analytical processor assembly.