Climatic High Low Temperature Thermal Shock Impact Test Chamber
USD $19500 - $50000 /Set
Min.Order:1 Set
Guangdong LIK Industry Co., Ltd
Climatic High Low Temperature Thermal Shock Impact Test Chamber
Thermal Shock Test Chamber isused to test the bearing extent of the material structures and composite material in an instant and continuous high temperature and extremely low temperature environment , that is in the shortest time to test its thermal expansion and contraction caused by chemical change or physical harm. Testing box is divided into two parts, one is high-temperature zone, another is low-temperature zone, the testing samples are placed in the moving basket, using unique heat storage and cool storage, the cylinder taking basket moves up and down in hot zone and cold zone to complete the extremely high and low temperature impact testing.
Applicable range
Climatic High Low Temperature Thermal Shock Impact Test Chamber are applicable for testing the changes in physical of the electronic chip IC, PCB, semiconductor ceramic and polymer materials. And composite material and material structure's result which under continuous environment with high temperature or low temperature shock in short time; it means this product can test the material's chemical change or physics change by expansion and contraction within short time. It's application to metal, plastic, rubber, food, electronic etc.alternation environment.
Features(Climatic High Low Temperature Thermal Shock Impact Test Chamber)
1. With the 7 inches large color control screen, the running status are displayed clearly.
2.User can save 32 test programs written by themselves.is over 20, and it avoid the chemical couple from stainless steel or aluminum.
3. According to reset time requirments, the machine can automatically set precooling and preheating temperature to adjust the working status of the machine to be optimal.
4.Lowest error, high speed, test samples exposure smooth.
5. Energy saving, low consumption, low noise design.
6. Friendly human-computer interface, with full functions of program setting and troubleshooting
7. The chambers are all designed into integral three boxes if the inside size less than 1 cubic meter and equipped with a unique subequipment, it could satisfy test request of different sizes. If the inside size more than 1 cubic meter, the chambers are designed into split two-box type.
8. Intelligent color microcomputer control system as below:
9. high competitive factory price with high quality and power after-sales service.
Specifications and technical parameters
Model LTS-XX | 271916 | 100A | 150A | 200A | 252A | 31.5B | 100B | 150B | 200B | 252B | 31.5C | 100C | 150C | 252C |
Structure | precooling box, preheating box, test box; two-box or three box selectable | |||||||||||||
Valve device | Forced air valve device | |||||||||||||
Inside material | SUS304 stainless steel | |||||||||||||
Outside material | SUS304 stainless steel or cold rolled steel with power spraying. | |||||||||||||
Test plate | Stainless steel plate | |||||||||||||
Refrigerating system | Semi-hermetic double-stage compressor | |||||||||||||
Cooling way | Water-cooled/Air Cooled | |||||||||||||
Environmental temp. | 0ºC~+30ºC | |||||||||||||
Preheating temp. | +60ºC~+180ºC | +60ºC~+180ºC | +60ºC~+180ºC | |||||||||||
Precooling temp. | -10ºC~-55ºC | -10ºC~-65ºC | -10ºC~-80ºC | |||||||||||
High temp. shock | +60ºC~+150ºC | +60ºC~+150ºC | +60ºC~+150ºC | |||||||||||
low temp. shock | -10ºC~-40ºC | -10ºC~-50ºC | -10ºC~-60ºC | |||||||||||
Temp. deviation | +2ºC | |||||||||||||
Simulation load(kg) | 10 | 10 | 15 | 20 | 5 | 10 | 15 | 20 | 5 | 10 | 20 | |||
High temp.shock speed(3-box) | RTºC~+150ºC/5min | RTºC~+150ºC/5min | RTºC~+150ºC/5min | |||||||||||
low temp.shock speed(3-box) | RTºC~-40ºC/5min | RTºC~-50ºC/5min | RTºC~-60ºC/5min | |||||||||||
High temp.shock speed(2-box) | -40ºC~+150ºC/5min | -50ºC~+150ºC/5min | -60ºC~+150ºC/5min | |||||||||||
Low temp.shock speed(2-box) | +150ºC~40ºC/5min | +150ºC~55ºC/5min | +150ºC~65ºC/5min | |||||||||||
Preheating time(min) | 25 | 30 | 40 | 45 | 25 | 30 | 40 | 45 | 25 | 30 | 45 | |||
Precooling time(min) | 60 | 75 | 100 | 110 | 70 | 85 | 100 | 110 | 70 | 85 | 110 | |||
Temperature sensor | PT100 | |||||||||||||
Controller | Program-controlled liquid crystal touch screen | |||||||||||||
Setting range | -100ºC~200ºC/TI, E: OH OOM ~999H 59M/ CYCLE: 0 CYCLE~10000 CYCLE | |||||||||||||
Resolution ratio | Temperature: 0.01ºC/time:1min | |||||||||||||
Output method | PID+PWM+SSR control mode | |||||||||||||
Additional feature | Air outlet and inlet perception inspection control/ RS-232 remote monitoring management system | |||||||||||||
Safety device | 1.With no-fuse protection switch. | |||||||||||||
2.Control system with phase sequence protection and low voltage electrical protection. | ||||||||||||||
3. Over load protection device for refrigeration compressor | ||||||||||||||
4.Refrigeration compressor high and low voltage protection switch. | ||||||||||||||
5.With over-heat protection switch. | ||||||||||||||
6.Refrigeration compressor over oil pressure protection. | ||||||||||||||
7.Overload protection for circulation fan motor | ||||||||||||||
Customized service | Welcome to Non-standard,Specail requirements,OEM/ODM orders. | |||||||||||||
Details of model: | ||||||||||||||
Model | Inside Dimension (W*D*H mm) | Power supply | Power/kw | Water tower | Water pipe diameter (the entry pressure of water) must not be less than 2kg | |||||||||
271916 | 500*1550*500 | 380V, 3-phase, 43A | 35kw | 15 tons | 2 inches | |||||||||
31.5B | 350*350*300 | 380V, 3-phase, 55A | 36.3kw | 10 tons | 2 inches | |||||||||
31.5C | 350*350*300 | 380V, 3-phase, 62A | 40.9kw | 10 tons | 2 inches | |||||||||
100A | 500*400*500 | 380V, 3-phase, 50A | 33kw | 10 tons | 2 inches | |||||||||
100B | 500*400*500 | 380V, 3-phase, 55A | 36.3kw | 10 tons | 2 inches | |||||||||
100C | 500*400*500 | 380V, 3-phase, 70A | 46.2kw | 20 tons | 2 1/2 inches | |||||||||
150A | 600*500*500 | 380V, 3-phase, 55A | 36.3kw | 15 tons | 2 inches | |||||||||
150B | 600*500*500 | 380V, 3-phase, 62A | 40.9kw | 15 tons | 2 inches | |||||||||
150C | 600*500*500 | 380V, 3-phase, 74A | 48.8kw | 25 tons | 2 inches | |||||||||
200A | 1000*400*500 | 380V, 3-phase, 65A | 42.9kw | 15 tons | 2 inches | |||||||||
200B | 1000*400*500 | 380V, 3-phase, 73A | 48.2kw | 25 tons | 2 1/2 inches | |||||||||
252A | 700*600*600 | 380V, 3-phase, 65A | 42.9kw | 15 tons | 2 inches | |||||||||
252B | 700*600*600 | 380V, 3-phase, 73A | 48.2kw | 25 tons | 2 1/2 inches |
Products image(Climatic High Low Temperature Thermal Shock Impact Test Chamber)
How to Contact Us?
Please Send your inquiry Details in the below Or send to my mail below directly. We promise reply your inquiry on time.