Custom Design CSSD Sterilizer In Limited Space For Medical Centers
Negotiable /Set
Min.Order:1 Set
Automatic Hinge Door CSSD Sterilizer 1000 Liter With Safety Working System
Single Door 316L Chamber CSSD Autoclave With Steam Generator Touch Screen
Multiple Sterilization Cycles CSSD Autoclave 300 Liter With PLC Control System
Floor-standing Hospital CSSD Autoclave 450 Liter For Surgical Instruments
User - Friendly SS316 Chamber HMI Double Door Autoclave For Biological Engineering
Recessed Double Door Autoclave With Sanitary 0.22 m Air Admission Filter
Custom Design Large CSSD Sterilizer In Limited Space For Medical Centers
Description:
High capacity to ensure excellent performances even at productivity peaks. These steam
sterilizers are characterized by a great portability thanks to standard and customized cycle
programmes, in an effort to gain the best results and optimize time, energy and resources.
Custom Design for Limited Space:
Medpharm’s strong engineering capability allows for highly customized autoclave design.
Facilities with space layout limitations will benefit from custom narrow design autoclaves
which provide high capacity in a limited space. Narrow design autoclaves allow for more
autoclaves in a given space to ensure continued sterile processing in case of autoclave
downtime.
Sterilizer Cycles:
All our hospital sterilizers include Gravity,Vacuum and Liquid cycle settings. A Test/Vac cycle is provided for utilizing Bowie-Dick™ tests. For surgical packs, select one of the vacuum cycles. For the sterilization of liquids in open or vented containers, select a liquids cycle. The time-tested and reliable Microcomputer Control is an industrial microprocessor providing accuracy and automation for all customer requirements. This simple, versatile, control has become the first choice for both sterilizer users and service technicians. Uniform Heat Distribution:Fully jacketed chambers ensure uniform heat distribution to ensure consistent serialization
conditions for all loads in chamber. A chamber that is not fully jacketed may have cool spots
which can cause improper sterilization.
Main Parameters:
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.24 |
600*600*670 |
1500*1800*1010 |
700 |
20 |
230 |
2 |
MD-0.36 |
600*600*1000 |
1500*1800*1340 |
800 |
25 |
240 |
2 |
MD-0.6 |
610*910*1170 |
1500*1900*1510 |
1250 |
30 |
260 |
3 |
MD-0.8 |
610*910*1450 |
1500*1900*1790 |
1400 |
35 |
280 |
3 |
MD-1.0 |
680*1180*1250 |
1600*2000*1590 |
1550 |
40 |
300 |
4 |
MD-1.2 |
680*1180*1500 |
1600*2000*1840 |
1950 |
45 |
320 |
4 |
MD-1.5 |
680*1180*1870 |
1600*2000*2210 |
2150 |
50 |
350 |
4.5 |
MD-2.0 |
1000*1200*1700 |
2000*2000*2040 |
2400 |
60 |
400 |
4.5 |
MD-3.0 |
1000*1500*2000 |
2000*2200*2340 |
2950 |
90 |
500 |
5 |
MD-4.0 |
1000*1500*2670 |
2000*2200*3010 |
3600 |
120 |
600 |
6 |
MD-5.0 |
1000*1500*3340 |
2000*2200*3680 |
4500 |