Single stage Hydraulic Pressure Accumulator with 6.30 - 31.5MPa Nominal pressure
USD $1 - $10/ /Set
Min.Order:1 Set
S type unidirectional valve , Tube check valve hydraulic valve directional control valve
Compact Pilot Water Solenoid Valve 1/2 inch 20bar Orifice 10mm 110V AC PXC-04 NBR
0.5 - 16 bar Brass 2 Way Steam Solenoid Valves Normally Open High Temperature
23QDF electromagnetic gas valve , Solenoid valve solenoid valve, multi-valve Modular throttle
Pilot Operated Solenoid Valve , Normally Closed 2 Way Air Pilot Valve 1/2\" BSP 15mm PX-15 NBR
Standard Pilot Sandwich Modular Controls Hydraulic Valves For Hydraulic Systems
AJ Application valve group for accumulator safety valve , Directional Control valve
.Specification
AJ control valve group of accumulator used between hydraulic systems and the accumulator,it provide cut-off function for the accumulator and pressure overload protecting by discharging the oil to relief the pressure. Safety ball valve can maintain the adjusted pressure value which is needed by the system, when the pressure is over the value, the valve opens to prevent the system pressure continues to rise.
AJS
Dn | A | B | H | L | A1 | A2 | A3 | B1 | B2 | B3 | B4 | H1 | H2 | H3 | DS | Dp | DT |
10 | 90 | 85 | 50 | 236 | 25 | 45 | 68 | 21 | 39 | 43 | 16/23 | 25 | 27.5 | 85 | M27×2/M42×2 | 18 | 16 |
20 | 145 | 90 | 90 | 333 | 45 | 59 | 68 | 30 | 40 | 63 | 23 | 45 | 57.5 | 149 | M42×2/M60×2 | 38 | 28 |
32 | 155 | 100 | 90/95 | 340 | 45 | 72 | 68 | 38 | 47 | 75 | 30 | 45/47.5 | 52/54.5 | 154/159 | M60×2/M72×2 | 42 | 28 |
AJIS
Dn | A | B | H | L | A1 | A2 | B1 | B2 | B3 | B4 | B5 | H1 | H2 | H3 | H4 | DS | Dp | DT |
10 | 90 | 85 | 50 | 236 | 25 | 68 | 21 | 39 | 43 | 16/23 | 20 | 25 | 27.5 | 85 | 40 | M27×2/M42×2 | 18 | 16 |
20 | 145 | 90 | 90 | 333 | 45 | 68 | 30 | 40 | 63 | 23 | 20 | 45 | 57.5 | 149 | 43 | M42×2/M60×2 | 38 | 28 |
32 | 155 | 100 | 90/95 | 340 | 45 | 68 | 38 | 47 | 75 | 30 | 25 | 45/47.5 | 52/54.5 | 154/159 | 50 | M60×2/M72×2 | 42 | 28 |
1 Overview
AJ type accumulator control valve assembly by the shut-off valve, safety valve and relief valve, etc, installed between the accumulator and the hydraulic system for controlling the accumulator oil-off, overflow, unloading, etc. conditions. The main function of the manifold are set safe working pressure accumulator, the implementation of the hydraulic system for the fluid and packing; control flow passage between the accumulator and the hydraulic system off, that is, when the accumulator to the fluid supply system or to the accumulator charging system to absorb pulsation, compensation capacity and other conditions to open the valve manually when you need to stop working or accumulator repair manual ball valve closed, if necessary, can be used manually or unloading unloading valve solenoid unloading.
This type of control valve with reliable perfo