Good Quality 15 inch 6 Parameter Patient Monitor Dual TEMP IBP ETCO2 Printer Thermal recorder Trolley optional RPM-9000E
USD $500 - $900 /Set
Min.Order:1 Set
Beijing Carejoy Technology Co., Ltd.
Standard configuration:
Optional:
Specification: | ||
ECG Full lead: I, II, III, AVL, AVR, AVF and V Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s Band width: 0.05Hz-100Hz(3dB) Heart rate: Scope: 15 times/minute to 300 times/minutes Accuracy: ±1 time/minute Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time. Accuracy: Error rate < 20% Undetected rate < 20% ST section Scope: ±0.8mV Precision : < ±0.05mV SpO2 Detection scope: 0%-100% Accuracy ±1% 90%-100% ±2% 70%-89% NIBP Theory Electric oscillator Cuff gassing time less than 15 seconds First-time gassing pressure: dynamic state 24kPa(180 mmHg) Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m in -90min) and 30min(90 min -240min) Detection scope: Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg) Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg) Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg) Detection accuracy Static pressure: ±3mmHg Pulse rate: ±2% Resp Chest impedance method or concentration of carbon dioxide at end of respiration Scope of chest impedance method 0 time/minute – 100 minutes/minute Precision of chest impedance method time/minute Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) Detection precision of respiration rate: ±1 time/minute Temp Single/double path Type: Vascular/surface temperature Scope: 20℃~50℃ Accuracy: ±0.2℃ Invasive blood pressure (optional) Single/double path Type: direct and continuous detection Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg) Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k Pa(100mmHg) above ±2% Frequency response:DC-12Hz Input resistance: not less than 500 Sensitivity of sensor: 5μV/V/mmHg Motivation voltage:5V (DC) Accuracy of sensor: ±2%Isolation voltage: 4 kV |
Our company has been a professional manufacturer & distributor for high-tech medical equipments since 2001.
We aims to provide the costeffective, reliable performance products. By collaborating with famous universities
and organizations, the company has designed and produced several types medical equipments in China market.
The quality management system of our company is ISO13485 certified.
Our products are also CE certified by MedCert Germany CE 0482.
Our company has a considerable market share in China domestic market and a growing increase in international market.
We aims to build good business relationships with more international distributors and customers sincerely.
We assures dealers and clients to continue provide products with innovative design, reliable quality, competitive prices
and rapid & effective customer service