CE Cheap Large-inch Multi-Parameter Patient Monitor price
USD $300 - $800 /Set
Min.Order:1 Set
Beijing Carejoy Technology Co., Ltd.
Features:
Ergonomic design, portable, convenient for use
15" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SPO2 technology can work accurate during motion and low perfusion
Anti AC & high-frequency electrosurgical &defibrillator’s interference
Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
Audible & visual alarm available, adjustable
Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
Optional software upgrading based on USB
Wired/wireless networking with central monitoring system, up to 64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data
Multi-language i.e. English, Spanish, Turkish.
Super long life rechargeable Lithium battery upto 4 hours of working time
Suitable for adult, pediatrics and neonate patients
Standard configuration:
ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Optional:
Dual TEMP
Dual IBP
ETCO2 (side stream)
Thermal recorder
Wall mount
Trolley
Specification:
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy ±1% 90%-100%
±2% 70%-89%
NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20℃~50℃
Accuracy: ±0.2℃
Invasive blood pressure (optional)
Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500k
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV
We have been a professional manufacturer & distributor for high-tech medical equipments since 2001.
We aims to provide the cost-effective, reliable performance products. By collaborating with famous universities and organizations, the company has designed and produced several types medical equipments in China market. The quality management system of ous is ISO13485 certified. Our products are also CE certified by MedCert Germany CE 0482. We have a considerable market share in China domestic market and a growing increase in international market.
We aims to build good business relationships with more international distributors and customers sincerely. We assures dealers and clients to continue provide products with innovative design, reliable quality, competitive prices and rapid & effective customer service.
We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of eighteen months (six months for spare parts) from date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.