12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional
12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional
12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional
12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional
12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional

12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional

USD $460 - $550 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Port:
Beijing or Tianjin
Payment Terms:
Credit Card

Quick Details View All >

Brand Name:
Brandnew
Model Number:
RPM-9000A
Place of Origin:
Beijing, China

Beijing Carejoy Technology Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: Ultrasound Scanner ,Patient Monitor ,ECG Machine ,Pulse Oximeter ,Holter

Product Details

Patient Monitor

 

Features:   

  • Ergonomic design, portable, convenient for use
  • 12.1" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti AC &high-frequency electrosurgical & defibrillators interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Optional software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, Turkish.
  • Super long life rechargeable Lithium battery upto 4 hours of working time

  • Suitable for adult, pediatrics and neonate patients

Standard configuration:            

Optional:            

Specification:

 

 

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
ST section 
Scope:     ±0.8mV
Precision : 
< ±0.05mV

SpO2

Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 

NIBP 

Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa
(180 mmHg)
Manual selection: 9.3kPa
(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa
(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size
:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min
(90 min -240min)
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa
~31.3kPa       (20mmHg~235mmHg)
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg
; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
(including baby)
Detection precision of respiration rate: ±1 time/minute 

Temp

Single/double path 
Type:    Vascular/surface temperature 
Scope:    20
~50
Accuracy:  ±0.2

Invasive blood pressure (optional)

Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response
:DC-12Hz
Input resistance: not less than 500
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage
:5V (DC)
Accuracy of sensor: ±2
%Isolation voltage: 4 kV

 12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional12 inch 6 Parameter Multifunction Patient Monitor Dual TEMP Dual IBP ETCO2 side stream Thermal recorder Trolley optional

Contact Supplier

Ms. Frances Wang Sales Manager Chat Now
Telephone
0086-010-82125963
Mobile
0086-18101035075
Address
Suite302, No. 2 Building, Changping Road No. 97, Shahe, Changping Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~