CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A
CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A
CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A
CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A
CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A

USD $450 - $550 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Beijing Tianjin Qingdao Shanghai
Payment Terms:
Credit Card PayPal

Quick Details View All >

Type:
Other, Nursing machine
Brand Name:
Carejoy
Model Number:
RPM-9000A
Place of Origin:
Beijing, China

Beijing Carejoy Technology Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: Ultrasound Scanner ,Patient Monitor ,ECG Machine ,Pulse Oximeter ,Holter

Product Details

Product Description

 

Features:

 

Ergonomic design, portable, convenient for use

12.1" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters

Unique digital SPO2 technology can work accurate during motion and low perfusion

Anti AC & high-frequency electrosurgical & defibrillator’s interference

Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others

Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events

ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation

Audible & visual alarm available, adjustable

Patient information management function

Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room

Optional software upgrading based on USB

Wired/wireless networking with central monitoring system, up to 64 beds in one group

Built-in 3 trace thermal recorder for printing real-time and historical data

Multi-language i.e. English, Spanish, Turkish.

Super long life rechargeable Lithium battery upto 4 hours of working time

 

Suitable for adult, pediatrics and neonate patients

 

Standard configuration:

 

ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery

 

Optional:

 

Dual TEMP

Dual IBP

ETCO2 (side stream)

Thermal recorder

Wall mount

Trolley

 

 

Specification: 

 

ECG

 

Full lead: I, II, III, AVL, AVR, AVF and V

Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV

Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s

Band width: 0.05Hz-100Hz(3dB)

Heart rate:

Scope: 15 times/minute to 300 times/minutes

Accuracy: ±1 time/minute

Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.

Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.

Accuracy: Error rate < 20%

Undetected rate < 20%

ST section

Scope: ±0.8mV

Precision : < ±0.05mV

 

SpO2

 

Detection scope: 0%-100%

Accuracy ±1% 90%-100%

±2% 70%-89%

 

NIBP

 

Theory Electric oscillator

Cuff gassing time less than 15 seconds

First-time gassing pressure: dynamic state 24kPa(180 mmHg)

Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)

18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),

Automatic detection period: 1 minute to 240 minutes

Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m

in -90min) and 30min(90 min -240min)

Detection scope:

Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)

Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)

Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)

Detection accuracy

Static pressure: ±3mmHg

Pulse rate: ±2%

 

Resp

 

Chest impedance method or concentration of carbon dioxide at end of respiration

Scope of chest impedance method 0 time/minute – 100 minutes/minute

Precision of chest impedance method time/minute

Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol

Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)

Detection precision of respiration rate: ±1 time/minute

 

Temp

 

Single/double path

Type: Vascular/surface temperature

Scope: 20℃~50℃

Accuracy: ±0.2℃

 

Invasive blood pressure (optional)

 

Single/double path

Type: direct and continuous detection

Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)

Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k

Pa(100mmHg) above ±2%

Frequency response:DC-12Hz

Input resistance: not less than 500k

Sensitivity of sensor: 5μV/V/mmHg

Motivation voltage:5V (DC)

Accuracy of sensor: ±2%Isolation voltage: 4 kV

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000ACE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000ACE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000ACE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000ACE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A

Company Information

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000ACE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A 

Packaging & Shipping

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A 

Hot selling

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A 

Contact information

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A 

CE Certification

CE approved 6 Parameter Patient Monitor /BP monitor/ECG monitor RPM-9000A 

Contact Supplier

Ms. Frances Wang Sales Manager Chat Now
Telephone
0086-010-82125963
Mobile
0086-18101035075
Address
Suite302, No. 2 Building, Changping Road No. 97, Shahe, Changping Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Ward Nursing Equipments
Categories
Hi~