SSN-20E,USB Data Logger for Temperature and Humidity record with Extended Temperature Range
Negotiable /Piece
Min.Order:30 Pieces
Xiamen Wellzion Electronics Co., Ltd.
Dew point and more professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.
User can plug data logger straight into PC’s USB port without any cables. Before getting started, user need to install USB driver and DGraphTM software, provided on the CD which is included in product packing box. All the software can run under Windows XP, Vista, 7 or 8 or 10(32 bit and 64 bit Versions). User can easily use DGraphTMsoftware to setup sample rate(from 10 seconds to 12 hours), high/low alarm limit and start/stop method , and download data to PC, etc. And then user can view, analyse and print the data, or export other file formats(txt, xsl, csv, bmp, jpg).
Especially, for some professional applications, user can set access password, name each channel, enable/disable specified channel, input calibration data for each channel, disable LED indication for saving power, and select sample mode(Instant, Average, Maximum and Minimum), etc.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Relative Humidity | Model | SSN-22E | SSN-20E |
Measurement Range | 0 to 100%RH | ||
Accuracy(Typ.) | ±3%RH | ||
Resolution(Typ.) | 0.1%RH | ||
Temperature | Measurement Range | -40 to 125°C(-40 to 257℉) | |
Accuracy(Typ.) | ±0.3°C(±0.5℉) | ||
Resolution(Typ.) | 0.1°C(0.2℉) | ||
Sensor Location | Enternal | ||
LCD | Support | Not Support | |
Memory Capacity | 64KBytes(Total 32,000 readings for all channels) | ||
Sample Rate | User selectable from once every 10 seconds to once every 12 hours | ||
PC Software | DGraph software and USB driver required (Included in CD) | ||
Power Supply | User replaceable 1/2AA 3.6V lithium battery,1200mAh | ||
Battery Life | Approx.3 Years @ 1 Minute Sample Rate | ||
Dimentions | 120mm×37mm×23mm(4.8"×1.5"×0.9") | ||
Case Material and Weight | ABS;Approx.80grams(2.82 oz) |
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Model | Measurement Parameters | Range | Accuracy (Typ.) | LCD Display | Readings | Sample Rate | Sensor | Battery Life |
Location | (Years) | |||||||
SSN-20 | Temperature | -35~80°C | ±0.3°C(±0.5°F) | NO | 32000 | 2s~24h | Internal | 3 |
Relative Humidity | 0~100%RH | ±3%RH | ||||||
SSN-22 | Temperature | -35~80°C | ±0.3°C(±0.5°F) | YES | 32000 | 2s~24h | Internal | 3 |
Relative Humidity | 0~100%RH | ±3%RH | ||||||
SSN-20E | Temperature | -40~125°C | ±0.3°C(±0.5°F) | NO | 32000 | 2s~24h | External | 3 |
Relative Humidity | 0~100%RH | ±3%RH | ||||||
SSN-22E | Temperature | -40~125°C | ±0.3°C(±0.5°F) | YES | 32000 | 2s~24h | External | 3 |
Relative Humidity | 0~100%RH | ±3%RH | ||||||
SSN-21 | Temperature | -35~80°C | ±0.2°C(±0.4°F) | NO | 32000 | 2s~24h | Internal | 3 |
Relative Humidity | 0~100%RH | ±2%RH | ||||||
SSN-23 | Temperature | -35~80°C | ±0.2°C(±0.4°F) | YES | 32000 | 2s~24h | Internal | 3 |
Relative Humidity | 0~100%RH | ±2%RH | ||||||
SSN-21E | Temperature | -40~125°C | ±0.2°C(±0.4°F) | NO | 32000 | 2s~24h | External | 3 |
Relative Humidity | 0~100%RH | ±2%RH | ||||||
SSN-23E | Temperature | -40~125°C | ±0.2°C(±0.4°F) | YES | 32000 | 2s~24h | External | 3 |
Relative Humidity | 0~100%RH | ±2%RH |