HSA2030B,3.2ghz hantek spectrum analyzer with tracking generator

HSA2030B,3.2ghz hantek spectrum analyzer with tracking generator

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
5000 Piece / Pieces per Month
Port:
xiamen shenzhen
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Brand Name:
Hantek
Model Number:
HSA2030B

Xiamen Wellzion Electronics Co., Ltd.

Business Type: Trading Company
Xiamen Fujian China
Main Products: Power Supply ,Oscilloscope ,Multimeter ,Spectrum Analyzer ,Temperature Test Instruments

Product Details

HSA2030B,3.2ghz hantek spectrum analyzer with tracking generator

Function & Benefits
  • 5.7 inch highlight color display 
  • Frequency range: 9KHz-3GHz (tunable to 9KHz) AC Coupled
  • Built-in 3GHz tracking generator
  • Optimal sensitivity: -161dBm
  • 7800mAh Li-ion battery for over 4 hours continuous operation
  • PC software can achieve the management and storage of testing data
  • Integration USB_Host & USB_Device,support USB flash disk memory,optional WIFI/LAN
Specifications

 

ModelHSA2030AHSA2030B
Frequency Characteristic
Frequency Range9KHz~3.2GHz AC Coupled9KHz~3.2GHz AC Coupled 5M~3.2GHz TG
Frequency Resolution1Hz
Reference Frequency10MHz
Frequency Readout Accuracy±(frequency indication*frequency reference uncertainty +1%*span +20%RBW +marker resolution +1Hz)
Frequency aging rate±1ppm/year (0°C~50°C,Reference is 25°C)
Temperature stability±1ppm/year
Marker Resolution(Frequency span)/(number of sweep points-1)
Resolution Bandwidth(RBW)
Filter Bandwidth(RBW) 10Hz to 1MHz,1-3-10 sequence
Accuracy±5%  RBW=10Hz~1MHz nominal
Video Bandwidth(VBW)1Hz to 1MHz,1-3-10 sequence(-3dB bandwidth)
Video Bandwidth Accuracy±10% VBM=1Hz~1MHz nominal
Displayed Average Noise Level (normalized to1Hz)
Preamp off9K~1MHz-108dBm,typical -127dBm
1MHz ~10MHz-128dBm,typical -146dBm
10MHz ~500MHz-142dBm,typical -146dBm
500MHz ~2.5GHz-141dBm,typical -145dBm
2.5GHz ~3.2GHz-140dBm,typical -144dBm
Preamp on9K~1MHz-131dBm,typical -150dBm
1MHz ~10MHz-148dBm,typical -163dBm
10MHz ~500MHz-161dBm,typical -164dBm
500MHz ~2.5GHz-159dBm,typical -162dBm
2.5GHz ~3.2GHz-158dBm,typical -161dBm
SSB Phase Noise (20°C~30°C, 500MHz Central Frequency)
Carrier Offset10K< -92 dBc/Hz, typical -95 dBc/Hz
30K< -93 dBc/Hz, typical -96 dBc/Hz
100K< -95 dBc/Hz, typical -97 dBc/Hz
1MHz< -117 dBc/Hz, typical -119 dBc/Hz
Sweep Time
Sweep RangeSpan >100Hz2ms to 1000s
Span=0Hz600ns to 200s
Sweep ModeContinuous, single
Trigger SourceFree run; video; external
Trigger slopeSelectable positive or negative edge
Trigger delaySpan =0Hz±12ms to ±12s nominal
Frequency Counter
Counter Resolution1Hz
Accuracy± (marker frequency×frequency reference uncertainty+counter resolution)
Level Display Range
Log Scale and Units1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed
Linear Scale and Units0 to 100%,10 divisions displayed
Scale UnitdBm,dBmV,dBuV,Watts,Volts
Sweep (Trace) Points461
Number of Markers4
DetectorsNormal, positive peak, dample, negative peak, RMS
Number of Traces4
Trace FunctionsClear/write, maximum hold, minimum hold, average, check,close
Level Measurement Error±1.5dB(excluding input VSWR mismatch) 
20~30°C,peak detector, preamplifier off, input signal -50dBm to 0dBm
Reference Level
Second Harmonic Distortion(SHI)<65dBc,50MHz~3GHz
(Mixer level -30dBm,attenuator =0dB,preamp off,20°C~30°C)
TOI50~300MHz+8dBm,Third-order intermodulation products:2 x -20dBm;
frequency separation 100KHz:attenuation = 0dB;
preamp off,20°C~30°C
300MHz~3.2GHz+10dBm
Input Related Spurious<-75dBc,(input mixer = -30dBm)
Inherent Residual Response<-90dBm,typical -98dBm
(Input terminated and 0 dB RF attenuation, preamplifier off)
RF Input VSWR10MHz to 3.2GHz<1.5:1, nominal         Attenuator setting 10~20dB
10MHz Reference/External Trigger Input
Reference Iinput Frequency10MHz
Reference Input Amplitude0~10dBm
Trigger Voltage5V TTL level
Connector and Output ImpendenceN female;(50Ω)
Gennral Characteristic
LanguageEnglish,Chinese,Chinese Traditional
Display 5.7 inch,640*480 resolution,64M color LCD display
Dimensions260mm* 220mm*75mm
Weight2.9kg(with battery),2.6kg(without battery)

 

500MHz ~2.5GHz -141dBm,typical -145dBm
2.5GHz ~3.2GHz -140dBm,typical -144dBm
Preamp on 9K~1MHz -131dBm,typical -150dBm
1MHz ~10MHz -148dBm,typical -163dBm
10MHz ~500MHz -161dBm,typical -164dBm
500MHz ~2.5GHz -159dBm,typical -162dBm
2.5GHz ~3.2GHz -158dBm,typical -161dBm
SSB Phase Noise (20°C~30°C, 500MHz Central Frequency)
Carrier Offset 10K < -92 dBc/Hz, typical -95 dBc/Hz
30K < -93 dBc/Hz, typical -96 dBc/Hz
100K < -95 dBc/Hz, typical -97 dBc/Hz
1MHz < -117 dBc/Hz, typical -119 dBc/Hz
Sweep Time
Sweep Range Span >100Hz 2ms to 1000s
Span=0Hz 600ns to 200s
Sweep Mode Continuous, single
Trigger Source Free run; video; external
Trigger slope Selectable positive or negative edge
Trigger delay Span =0Hz ±12ms to ±12s nominal
Frequency Counter
Counter Resolution 1Hz
Accuracy ± (marker frequency×frequency reference uncertainty+counter resolution)
Level Display Range
Log Scale and Units 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed
Linear Scale and Units 0 to 100%,10 divisions displayed
Scale Unit dBm,dBmV,dBuV,Watts,Volts
Sweep (Trace) Points 461
Number of Markers 4
Detectors Normal, positive peak, dample, negative peak, RMS
Number of Traces 4
Trace Functions Clear/write, maximum hold, minimum hold, average, check,close
Level Measurement Error "±1.5dB(excluding input VSWR mismatch)
20~30°C,peak detector, preamplifier off, input signal -50dBm to 0dBm"
Reference Level
Second Harmonic Distortion(SHI) "<65dBc,50MHz~3GHz
(Mixer level -30dBm,attenuator =0dB,preamp off,20°C~30°C)"
TOI 50~300MHz "+8dBm,Third-order intermodulation products:2 x -20dBm;
frequency separation 100KHz:attenuation = 0dB;
preamp off,20°C~30°C"
300MHz~3.2GHz +10dBm
Input Related Spurious <-75dBc,(input mixer = -30dBm)
Inherent Residual Response "<-90dBm,typical -98dBm
(Input terminated and 0 dB RF attenuation, preamplifier off)"
RF Input VSWR 10MHz to 3.2GHz <1.5:1, nominal Attenuator setting 10~20dB
10MHz Reference/External Trigger Input
Reference Iinput Frequency 10MHz
Reference Input Amplitude 0~10dBm
Trigger Voltage 5V TTL level
Connector and Output Impendence N female;(50Ω)
Gennral Characteristic
Language English,Chinese,Chinese Traditional
Display 5.7 inch,640*480 resolution,64M color LCD display
Dimensions 260mm* 220mm*75mm
Weight 2.9kg(with battery),2.6kg(without battery)

Contact Supplier

Ms. Melissa Zhang Chat Now
Telephone
86-592-5562446
Fax
86-592-5562446
Address
ROOM 608,B BUILDING,SEG E-MART, NO.806 YUANSHAN NAN ROAD,XIAMEN,FUJIAN,CHINA Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Spectrum Analyzers
Categories
Hi~