E7042B,4.4GHz All-in-One Combo Anayzer Integrated Optical Microscope
Negotiable /Piece
Min.Order:1 Piece
Xiamen Wellzion Electronics Co., Ltd.
E7042B,4.4GHz All-in-One Combo Anayzer Integrated Optical Microscope
Verify RF and fiber-based cell site performance with a single instrument
The SignalPROFILER combines the power and functionality of cable and antenna system analysis,fiber inspection,spectrum analysis, cellular signal demodulation, interference analysis, signal coverage mapping and RF/optical power measurements in a single instrument.
As a multi-functional instrument, the SignalPROFILER can be configured to meet your specific test needs at the time of purchase or at a later date as your test needs evolve.Additional measurement capability can be added on the fly in the field in a matter of seconds.
Designed specifically for wireless communication field engineers and technicians who install, maintain and troubleshoot wireless communication sites, the SignalPROFILER was developed to get the job done right-the first time-with multiple cutting edge features that deliver accurate results, improve productivity and reduce OPEX and CAPEX.
Standard Measurements & Applications (Cable & Antenna Analysis)
• Reflection-Return Loss or VSWR
• Fault Location – DFT/RL or DTF/VSWR
• Cable Loss
• 1-Port Phase
• Smith Chart
• FiberScope Fiber Connector Inspection (DML-OPI)
• Optical Power Meter (DML-OPM)
• Visual Fault Location (DML-VFL)
Standard Measurements & Applications (Spectrum Analysis)
• Spectrum Analysis
• Channel Power
• Occupied Bandwidth (OBW)
• Adjacent Channel Leakage Ratio (ACLR)
• Field Strength
• AM/FM
Optional Measurement Modes
• High Precision Power Meter (DML-015)
• Interference Analysis (DML-110)
• Coverage Mapping (DML-120)
• Transmission Measurement (DML-025)
• GPS Receiver (DML-999)
Cable Analyzer | |
Frequency | |
Frequency Range | 2MHz~4.4GHz (E7042B); 2MHz~6.1GHz (E7062B) |
Resolution | 1kHz |
Measurement Speed | |
Reflection | <0.8mS/point |
DTF | <1mS/point |
Data Points | 130, 259, 517, 1033, 2065 |
Measurement Accuracy | |
Corrected Directivity | 42dB (typical, after standard OSL calibration) |
38dB (typical, after eCAL calibration) | |
Output Power | OdBm (Nominal) |
Interference Immunity | |
On-channel | +20 dBm @ >1 MHz of carrier frequency |
Off-channel | +10 dBm within ± 10 kHz of carrier frequency |
Measurements | |
Return Loss | 0 to 60dB (resolution 0.01 dB) |
VSWR | 1:1 to 65:1 (resolution 0.01) |
Cable Loss | 0 to 30dB (resolution 0.01 dB) |
DTF Range (Distance) | 1500 meters (4921 feet) |
Connectors(Reflection / RF Out) | |
RF Out | Type N, female, 50Ω |
RF Out Damage Level | 25 dBm, ± 50 VDC peak |
Impedance | 50Ω |
Optical Measurements | |
Optical Microscope | |
Field of view | 680mm*510mm |
Resolution | 0.5mm |
Light source | Blue LED |
Focus control | Adjustable |
Dimensions | 175mm x 435mm |
Weight | 200g |
Optical Power Meter | |
Accuracy | ±0.25dB |
Probe Type | InGaAs 300μm |
Dynamic Range | -50dBm~+27dBm |
Resolution | 0.01 dBm, mW, uW, nW |
Wave Length | 850nm,980nm,1300nm,1310nm,1490nm,1550nm,1610nm |
Adapter | FC/SC/ST |
VFL | |
Output Power | 10mW |
Adapter | FC/PC |
Spectrum Analyzer | |
Frequency | |
Frequency Range | 9kHz~4.4GHz (E7042B); 9kHz~6.0GHz (E7062B) |
Tuning Resolution | 1Hz |
Aging | <± 1.0ppm/yr |
Frequency Span | 1 kHz to 4 or 6 GHz in 1-2-5 sequence (automode), and 0 Hz (zero span) |
Bandwidth | |
Resolution Bandwidth (RBW) | 10Hz to 3MHz in 1-3 sequence (auto or manually selectable) |
Video Bandwidth (VBW) | 10Hz to 3MHz in 1-3 sequence (auto or manually selectable) |
Spectral Purity (Phase Noise) | |
@ 1 kHz Offset from carrier | -90 dBc/Hz |
@ 10 kHz Offset from carrier | -100 dBc/Hz |
@ 100 kHz Offset from carrier | -105 dBc/Hz |
Amplitude | |
Dynamic Range | >100dB |
Measurement Range | DANL to maximum safe input level |
Maximum Safe Input | +30dBm (peak power, input attenuation > 15dB), 50VDC |
Amplitude Accuracy | ≤± 1.0dB |
Attenuator Range | 0dB to 55 dB in 5dB steps |
Displayed Average Noise Level (DANL) (Input terminated, RBW = 10 kHz, Attn = 0 dBm, Avg Detector) | |
Preamp Off | ≤ -148 dBm, typical (1MHz~1GHz) ≤ -138 dBm, typical (1GHz~6GHz) |
Preamp On | ≤ -160 dBm, typical (1MHz~1GHz) ≤ -154 dBm, typical (1GHz~6GHz) |
RF Power Meter | |
USB Smart RF Power Sensor | |
Frequency Range | 2MHz~6.1GHz |
Measurement Range | 1μW~100mW(-30~+20dBm) |
VSWR | 1.1 |
Resolution | 1dB, 0.1dB, 0.01dB, 0.001dB |
Dimension | 124 x 44 x 24 |
Weight | 250g |
Accuracy | Type, ±0.2dB |
Inline RF Power Meter | |
Frequency range | 300MHz to 4000MHz |
Measurement Range | 0.15W to 150W |
Insert Loss | 0.1dB |
VSWR | 1.1 |
Directivity | 30dB |
Accuracy | ±4%±0.05W(+15~+35°C); ±7%±0.05W(-10~+50°C) |
Connector | Type N(f), 50 Ω |
General Specifications | |
RF In | Type N, female, 50Ω |
RF In Damage | +30 dBm, +50 VDC |
USB host | Type A,1-Port(connect flash drive for data transfer) |
USB client | 5-pin mini-B (connect to PC for data transfer) |
LAN | 10M/100M LAN Port |
Internal | 1GB,>2000 saved measurement files |
External | Limited by size of USB flash drive |
Display | 8.4 inch TFT LCD (800 x 600) |
Demension | 258mm*173mm*74mm |
Weight | 3kg (6.6 lbs) |