Product Details

SA2100,power quality analyzer,portable power analyzer

Place of Origin Fujian, China
Brand Name OEM
Model Number SA2100
Power Electronic
Usage Other, Power Quality Analyzer

Product Features

SA2100,power quality analyzer,portable power analyzer

SA2100,power quality analyzer,portable power analyzer

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------

SA2100,power quality analyzer,portable power analyzer

Input
Voltage Input  
Input channels4 (3 phase  + neutral) DC coupling 
Max. Input Voltage  1000Vrms 
Range of nominal voltage  50 ~ 500V 
Max pulse peak voltage  6kV 
Bandwidth>3kHz
Input impedance  4MΩ/5pF 
Current Input 
Numbers of input  4 (3 phase + neutral) DC coupling 
Type  Clamp Current Sensor, with mV output 
Input range  1 to 3000Arms with supplied current clamp 
Input impedance  50kΩ 
Bandwidth>3kHz
Sampling System 
Resolution  8 channels 16 bits AD 
Sampling rate  20kS/s for each channel, 8 channels sample synchronously 
RMS sampling  5000 points for 10/12 cycles (according to IEC 61000-4-30) 
PLL sync  4096 points for 10/12 cycles (according to IEC61000-4-7) 
MeasurementMeasurement range Resolution  Accuracy 
Voltage/Current/Frequency  
Vrms (AC+DC)  1~1000Vrms  0.1Vrms  ±0.5% of nominal voltage
Vpk  1~1400Vpk  0.1Vpk  ±0.5% of nominal voltage
V(Crest Factor)  1.0~>2.8  0.01±5% 
Arms 
(supplied current clamp)  
1~1000A/3000/5000A 1A ±1%±2A
1~100A 0.1A ±1%±0.2A
Apk  1~4000Apk  1A  ±1%±2A
A(Crest Factor)  1~10  0.01±5% 
Frequency  42.5~57.5 (50Hz nominal)0.01Hz ±0.01%Hz
51~69 (60Hz nominal)0.01Hz ±0.01%Hz
Dips&Swells  
Vrms1/2  0~200% nominal voltage 0.1Vrms ±1% 
Arms1/2  1~3000A 1A ±1%±2A
Threshold value  Threshold is settable according to nominal voltage percentage 
Detectable events type: Dips, Swells, Interruption, Voltage Rapid Change.
Duration  hour-minute-second-microsecond 0.5 period1 period
Harmonic  
Harmonic number 1~50   
Inter-harmonic 1~49   
Harmonic voltage 0.0~100.0% 0.10%±0.1%±n×0.1% 
Harmonic current 0.0~100.0% 0.10%±0.1%±n×0.1% 
THD 0.0~100.0% 0.10%±2.5% 
DC relative 0.0~100.0% 0.10%±0.2% 
Frequency 0~3500Hz 1Hz 1Hz 
Phase -360°~ 0°  1°  ±n×1.5°
Power and energy  
Active power/apparent 1.0~20.00MW 0.1kW ±1.5±10 digits 
Power/reactive power 
Energy0.00kWh~200GWh 10Wh ±1.5±10 digits 
Power factor 0~1 0.01±0.03 
Flicker  
Pst (1min), Pst, Plt, PFS0.00~20.00  0.01±5% 
Unbalance  
Voltage0.0~5.0% 0.10%±0.5% 
Current0.0~20.0% 0.10%±1% 
Voltage phase -360°~ 0°  1°  ±2 digits
Current phase -360°~ 0°  1°  ±5 digits
Voltage Transient
Vpk ±6000Vpk 1V ±15% 
Vrms 10~1000Vrms 1V ±2.5% 
Min test time 50μs   
Sampling rate 20kS/s   
Inrush Current  
Arms (AC+DC)0~3000Arms  0.1±1%±5 digits
Inrush Duration6s~32min selectable10ms  ±20ms 
Logger
Recordinguser-defined parameters for 4 phases at the same time
Memory   Data stored in TF card, 8GB
Duration Time2 hrs to 1 year
Interval1s to 1 hrs
Wiring Combinations 
1Ø+NEUTRAL  Single phase with neutral 
1Ø SPLIT PHASE  Split phase 
1Ø IT NO NEUTRAL  Single phase system with two phase voltages without neutral 
3Ø WYE  3-phase 4-wire system, Y type 
3Ø DELTA  3-phase 3-wire system delta (Delta) 
3Ø IT  3-phase Y type without neutral 
3Ø HIGH LEG  4-wire 3-phase delta system (Delta) with center tapped high leg 
3Ø OPEN LEG  Open-delta (Delta) 3-wire system with two transformer windings 
2-ELEMENT  3-phase 3-wire system without current sensor on phase L2/B (2 Watt meter method) 
2 1/2-ELEMENT  3-phase 4-wire system without voltage sensor on phase L2/B 
General Characteristics 
Display5.6 inch  320× 240  Color TFT LCD 
Interface   USB Host,LAN
Memory   128M Flash memory  ;Standard 8G TF card  
Dimension  262mm×173mm× 66mm 
Weight  1.6 kg 
BatteryRechargeable Ni-Mh 7.2V 3.8Ah,>7 hours working time,4 hours charging time

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

SA2100,power quality analyzer,portable power analyzer

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

SA2100,power quality analyzer,portable power analyzer

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------

SA2100,power quality analyzer,portable power analyzer

 

Compare with Fluke Power Quality Analyzer

ModelHOIKI 3197SA2100
Test ItermsVoltage600V1000V
Voltage Accuracy±0.3%rdg.±0.2% f.s±0.5% of V nom
Current Accuracy±0.3%rdg.±0.2% f.s±accuracy of sensor±1%±5 digits
sensor7 optional3000A*4 standard
Frequency45~66Hz42.5~57.5Hz/51~69Hz
Power Accuracy±0.3%rdg.±0.2% f.s±accuracy of sensor±1.5%±10 digits
Apparent Power
Active Power
Reactive Power
Active Energy
Reactive Energy
Power Factor
Unbalance
Power QualityInrush Current
Dip & Swell
Interruption
Fliker×
GeneralData Memory4MB128MB
Interval settingAuto:1/2/5/10/30s,1/5/15/30/60s1/2/5/10/15/30s,1/2/5/10/15/30/60m
Connect Mode1 phase-2line/1phase-3 line/3 phase-3 line/3 phase-4 line1 phase-2line/1phase-3 line/3 phase-3 line/3 phase-4 line
Display4.7'' STN color LCD5.6'' TFT color LCD
LanguageJanpanese/English/ ChineseEnglish/Chinese
External In/Out××
PC/CF card×CF 8GB
InterfaceUSBUSB.LAN

 

Selection Guide

 

ModelSA2100SA2100E
Volts/Amps/HertzYesYes
Dips&SwellYesYes
Power/EnergyYesYes
UnbalanceYesYes
MonitorYesYes
ScopeYesYes
HarmonicYesYes
Inter-HarmoniYesNo
Transient VoltageYesNo
Inrush CurrentYesNo
FlikerYesNo
400HzYesNo
InterruptionYesYes
Memory Card8G
Standard CTFlexi.CT PY-3000A*4pcsFlexi.CT PY-3000A*3pcs

 