must solar Uninterrupted power supply 1kva-3kva with long back up time online ups
USD $128 - $1,010 /Piece
Min.Order:10 Pieces
Shenzhen Must Solar Power Co., Ltd.
Pure sine wave online ups1kva 2kva 3kva with inside battery (ups power supply)
Main Features:
True online UPS, 0 Transfer Time, Double Conversion
a. True on-line double conversion technology with advanced microprocessor control
b. Wide input voltage range with high frequency technology
c. Zero transfer time
d. Protection against all type of power problems
e. ups power supply has the self test while start
f. Site wiring fault warning
g. On-battery power-on function
h. Smart RS232 communication interface
i. Intelligent slot available
j. Sealed acid battery,free-maintenance battery in high frequency online ups 1kva 2kva 3kva
1.UPS Specification:
High Frequency Online UPS Castle Series UPS
C1KVA/C1KS,C2KVA/C2KS,C3KVA/C3KS 1000VA~3000VA Specifications
1.Output
Output | C1KVA/C1KS | C2KVA/C2KS | C3KVA/C3KS |
Rated Power | 1000VA/700W | 2000VA/1400W | 3000VA/2100W |
Output Voltage | 208VAC/220VAC/230VAC/240VAC | ||
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:1 | ||
Output Frequency (Synchronized- Mains) | 46~54Hz or 56Hz - 64Hz (Line mode) 50/60HZ/ ±0.05Hz( Battery mode) | ||
Regulation(Nominal) | ±1% | ||
Regulation (Battery mode) | ±1% | ||
Transfer time | 0 ms; less than 4 ms from inverter to bypass and vice versa | ||
Over current protection | Line Mode:10min@100%~130%; Battery Mode:30s@100%~130% | ||
Outlet | IEC*4/IEC*6/IEC*4+Terminal | ||
Harmonic Distortion | ≤2%THD(Linear Load); ≤5%THD(Non-Linear Load) |
2.Input
Input | C1KVA/C1KS | C2KVA/C2KS | C3KVA/C3KS |
Nominal Voltage | 160~300VAC@full load (110~300VAC@half load) | ||
Input Frequency | 46~54Hz / 56~60Hz | ||
Efficiency | 87% (AC mode)/83%(Battery Type) | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Over current protection | by AC fuse or by re-settable over current protector |
AVR Range (2 Bucks,2 Boosts) | Enhanced Buck: +15% of selected nominal voltage Buck mode: +5% of selected nominal voltage Boost mode: -5% of selected nominal voltage Enhanced Boost: -12.5% of selected nominal voltage |
Phase | Single phase with ground |
3.Battery
Battery type | Sealed lead acid Battery | ||
Rated Charging Voltage | 41.0Vdc / 81.9Vdc / 109.2Vdc | ||
Typical backup time | >5min | ||
Charging method | Smart pulse charging with two charging modes. Quick charging when battery is not fully charged, trickle charging when battery is 90% fully charged. | ||
Charging current(MAX) | 1.0A(C1KS-C3KS:4.0/8.0A) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) Thermal protection (CPU control) When temperature inside UPS is over 45°C, charger will stop charging for 2.5 minutes followed by an 1.5 minutes charging. The cycle will be repeated until the temperature is lower than 44°C. | ||
TemperatureCompension | Yes | ||
Numbers of Batteries | 3 | 8 | 8 |
4.Optional Features
ECO Mode | Support |
CVCF | Support |
PDU | Support |
Remote Panel | Wired Type,Up to 100M Length |
Parallel Redundancy | Up to 4 Units maxium(Option) |
5.Environmental and Safety
Operating Temperature | 0°C to 40°C (32°F to 104°F) | |
Transit/storage Temperature | -15°C to 55°C (5°F to 131°F) | |
Relative Humidity | 20-90%(NON-CONDENSING) | |
Operating Altitude | 0 ~ 3000 meters | |
Audible noise | 50 dBA | |
Safety Markings | BSMI | CE |
EMC | Class B, EN50091-2, FCC part15, IEC1000-2-2 | |
Quality control system | ISO 9001:2000 | |
Noise Level | <55db@1 Meter |
LED Version | Load Level/Battery Level/Battery;Mode/AC Mode/Bypass Mode/Fault |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continously Sounding |
LCD Version | Load/Battery/Input/Output/Operating;Mode Information |
6.Indicator Interface
Smart RS-232 | Software supports Windows Family. Sun Solaris,IBM Aix,Compaq True64, SGIIRIX ,FreeBSD.HP-UX,and MAC |
USB (Option) | Windows Family& MAC |
Internal Slot(Option) | SNMP/AS400 Relay Card/Rs485 |
EPO(Option) | Support Emergency Shutdown |
7.Physical
Dimensions: (D×H×W)mm | 400*145*220 | 460*192*348 | 460*192*348 |
N.W/G.W(kg) | 1KVA:14 / 1KS:7 | 2KVA:34 / 2KS:13.5 | 3KVA:35 / 3KS:14 |
Packing | PBP standard Packing,Export carton for each unit |
2.Online UPS Detail Picture:
C1k online ups details
C2k online ups with inside battery
3.Online ups assembly line :
4,Online ups Sockets and Cable:
5.ups & inverter Factory TouR:
All PBP hot sale products
HK fair in 2013
1KVA 2KVA 3KVA online high frequency ups manufacturer in china