220v online UPS 10000va with battery pack
USD $519 - $632.5 /Piece
Min.Order:5 Pieces
Shenzhen Must Solar Power Co., Ltd.
Main feature
Pictures
Description
Output | C1KVA/C1KS | C2KVA/C2KS | C3KVA/C3KS |
Rated Power | 1000VA/700W | 2000VA/1400W | 3000VA/2100W |
Output Voltage | 208VAC/220VAC/230VAC/240VAC | ||
Voltage Waveform | Pure Sine wave | ||
Crest Factor | 3:1 | ||
Output Frequency (Synchronized- Mains) | 46~54Hz or 56Hz - 64Hz (Line mode) 50/60HZ/ ±0.05Hz( Battery mode) | ||
Regulation(Nominal) | ±1% | ||
Regulation (Battery mode) | ±1% | ||
Transfer time | 0 ms; less than 4 ms from inverter to bypass and vice versa | ||
Over current protection | Line Mode:10min@100%~130%; Battery Mode:30s@100%~130% | ||
Outlet | IEC*4/IEC*6/IEC*4+Terminal | ||
Harmonic Distortion | ≤2%THD(Linear Load); ≤5%THD(Non-Linear Load) |
2.Input
Input | C1KVA/C1KS | C2KVA/C2KS | C3KVA/C3KS |
Nominal Voltage | 160~300VAC@full load (110~300VAC@half load) | ||
Input Frequency | 46~54Hz / 56~60Hz | ||
Efficiency | 87% (AC mode)/83%(Battery Type) | ||
Noise Filtering | Full time EMI/RFI filtering | ||
Over current protection | by AC fuse or by re-settable over current protector |
AVR Range (2 Bucks,2 Boosts) | Enhanced Buck: +15% of selected nominal voltage Buck mode: +5% of selected nominal voltage Boost mode: -5% of selected nominal voltage Enhanced Boost: -12.5% of selected nominal voltage |
Phase | Single phase with ground |
3.Battery
Battery type | Sealed lead acid Battery | ||
Rated Charging Voltage | 41.0Vdc / 81.9Vdc / 109.2Vdc | ||
Typical backup time | more than 5 min | ||
Charging method | Smart pulse charging with two charging modes. Quick charging when battery is not fully charged, trickle charging when battery is 90% fully charged. | ||
Charging current(MAX) | 1.0A(C1KS-C3KS:4.0/8.0A) | ||
Protection | Over current protection & Over charging voltage protection (SCR control) Thermal protection (CPU control) When temperature inside UPS is over 45°C, charger will stop charging for 2.5 minutes followed by an 1.5 minutes charging. The cycle will be repeated until the temperature is lower than 44°C. | ||
TemperatureCompension | Yes | ||
Numbers of Batteries | 3 | 8 | 8 |
4.Optional Features
ECO Mode | Support |
CVCF | Support |
PDU | Support |
Remote Panel | Wired Type,Up to 100M Length |
Parallel Redundancy | Up to 4 Units maxium(Option) |
5.Environmental and Safety
Operating Temperature | 0°C to 40°C (32°F to 104°F) | |
Transit/storage Temperature | -15°C to 55°C (5°F to 131°F) | |
Relative Humidity | 20-90%(NON-CONDENSING) | |
Operating Altitude | 0 ~ 3000 meters | |
Audible noise | less than 50 dBA | |
Safety Markings | BSMI | CE |
EMC | Class B, EN50091-2, FCC part15, IEC1000-2-2 | |
Quality control system | ISO 9001:2000 | |
Noise Level | less than 55db@1 Meter |
LED Version | Load Level/Battery Level/Battery;Mode/AC Mode/Bypass Mode/Fault |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continously Sounding |
LCD Version | Load/Battery/Input/Output/Operating;Mode Information |
6.Indicator Interface
Smart RS-232 | Software supports Windows Family. Sun Solaris,IBM Aix,Compaq True64, SGIIRIX ,FreeBSD.HP-UX,and MAC |
USB (Option) | Windows Family& MAC |
Internal Slot(Option) | SNMP/AS400 Relay Card/Rs485 |
EPO(Option) | Support Emergency Shutdown |
7.Physical
Dimensions: (D×H×W)mm | 400*145*220 | 460*192*348 | 460*192*348 |
N.W/G.W(kg) | 1KVA:14 / 1KS:7 | 2KVA:34 / 2KS:13.5 | 3KVA:35 / 3KS:14 |
Packing | PBP standard Packing,Export carton for each unit |
Typical Application
Server, Data center, Critical network devices, Sensitive electronic equipment, Telecom