Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

Negotiable /Meter

Min.Order:1000 Meters

Supply Ability:
3000 Meter / Meters per Month
Port:
Tianjin/Qingdao
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Hebei, China
Brand Name:
NBF
Model Number:
BV
Insulation Material:
XLPE
Type:
Other, Low/medium/high voltage
Application:
Other, Industrial,Construction Power Station,Industrial ,Underground

Hebei New Baofeng Wire & Cable Co., Ltd.

Business Type: Manufacturer,Trading Company
Cangzhou Hebei China
Main Products: Super high voltage XLPE insulated power cable ,medium & high voltage XLPE insulated power cable ,low voltage power cable and wire ,overhead insulated cable ,various stranded wire

Product Details

Specifications

1 IEC, ASTM, DIN, BS standard
2 ISO,CCC certification
3 Response within 12 hours
4 Free Sample
5 On time delivery

 

           Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

    

 

 

 

1.Using Feature:

(1.) The long-time working temperature of cable should not be highter than 70 oC

(2.) When core is in short-circuit(max 5s) the temperature should not exceed 160 oC

2. The description: 

 

Type

Name

Application

CU

AL

 

VV

 

VLV

PVC insulation&sheathed

Power cable

 

For laying indoors, in tunnel and in ducts, unable to bear extarnal mechanical forces

 

VV22

 

VLV22

PVC insulation&sheathed steel tape armour power cable

Laying in the ground, afire-resistant, unable to bear extarnal mechanical forces

3. Specification Size and Technical Data:     

Core number

Nominal Section(mm²)

D.C.Resistance in 20oC(Ω/km)

 

O.D.(mm)

Reference Weight(Kg/km)

CU

AL

Cu

Al

 

 

 

 

 

 

 

 

1 core

1.5

24

 

6.1

49.2

46.6

2.5

34

25

6.5

61.6

61.5

4

44

33

7.4

85.4

74.3

6

57

44

8.0

109

90.1

10

76

58

9.6

151

116

16

103

78

10.2

223

173

25

129

108

12.0

331

212

35

172

131

13.1

432

272

70

268

207

16.0

780

472

95

288

227

18.7

1060

561

150

435

335

22.1

1609

821

185

493

380

24.2

1966

1028

240

585

451

26.9

2513

1265

 

 

 

2 core

1.5

802

624

33.5

4108

 

2.5

20

 

10.2

116

117

4

27

21

11.0

148

159

6

36

27

12.8

207

194

10

46

35

13.8

262

228

16

62

48

15.4

351

301

25

83

63

18.5

532

456

35

113

88

22.0

777

572

50

131

101

24.3

1017

573

70

164

127

22.4

1201

735

95

208

160

25.2

1615

956

 
Electric Cables:

CU Conductor PVC Insulated PVC Sheathed Power Cable

1. The applications: Rated voltage (U0/U) 0.6/1kv  8.7/15KV  26/35kV in transmission & transformation line & for water-proofing purpose .

2. Standards: 60502IEC  ISO9001

3. Product features:

1) No necessary to heat up in advance while installing above 0oC.

2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).

3) Max. Permissible temperature at short circuit (5s. at longest): 250oC.

4) Permissible bending radius:

Single core: ≥20(d+D)±5%.

Three-core:≥15(d+D)±5%(D is the actual overall diameter of cable, and d is the actual overall diameter of conductor).

 Detailed Description

Cross-linked polyethylene insulated power cable not only has excellent electric and mechanical properties, but also has powerful resistance against chemical corrosion, heat-aging and environmental stress. Its structure is simple and using conveniently, also can be laid with no restriction of different level. The long term operating temperature is 90, and its  transmit capacitance  is large.

Our company can produce both flame retardant and non-flame retardant series of XLPE power cable.. Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards stated above..

The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cable according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on..

 
 
 
Nominal sectional area mm2Conductor No/Dia. mmNominal Insulated thick mmMax overall Dia. mmCondcutor Resistance at 20Min insulated resistance at 70MΩ/kmWeight Kg/km
2.59/0.410.84.27.410.01133.0
419/0.520.84.84.610.00948.0
619/0.640.85.63.080.008468.0
1049/0.521.07.61.830.0072115.0
1649/0.641.08.81.150.0062176.0
2598/0.581.211.00.7270.0058272.0
35133/0.581.212.50.5240.0052384.0
50133/0.681.416.50.3870.0051510.0
70189/0.681.416.50.2680.0045714.0
95259/0.681.19.50.1390.0035965.0
120259/0.761.822.00.1530.00321210.0
150259/0.851.825.00.1240.00321510.0

 

 

 

We also produce:

 

 flame-retardant control cable, XLPE insulated control cable, XLPE insulated flame-retardant control cable, low smoke halogen free flame-retardant control cable etc.

 

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

  Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmissionFactory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

Using Features & Main Performance

1, Rated voltage Uo/U includes 0.6/1kV, 1.8/3kV, 3.6/6kV, 6/6kV, 6/10kV, 8.7/10kV, 8.7/15kV,12/20kV, 12/20kV, 21/35kV, 26/35kV;

2, The permitted highest operating temperature of conductor for long-term working is 90°C .In short-circult (Max.long-term time is no more than 5 seconds) ,the highest temperature of conductor is not higher than250°C;

3, D.C. Conductor resistance complies with the stipulations of GB/T3956;0

4, PVC sheath cable Environment temperature in laying the cable should be no lower than 0 ;PE sheath cable Environment temperature in laying the cable should be no lower than -20 ; The Min. bending radius should be no less than 15 times of cable outer diameter;

5, The cable is laid without drop limit;

6, Working Frequency Voltage Test: for cable with UO of 1.8kV or lower: 2.5 UO+ 2kV/5 min without puncture for cable with UO of 3.6kV or higher: 3.5 UO / 5 min without puncture

7, Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73UO for the cable with of 3.6kV or higher.

 

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmissionFactory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

Instruction

 

1) No necessary to heat up in advance while installing above  0oC.

 

2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).

 

3)  Its structure is simple and using conveniently, also can be laid with no restriction of different level.

 

4)The long term operating temperature is 90, and its transmit capacitance is large.

 

5) When using it, please check the wire insulation from the appearance in case of causing any damage because of   transporting or storing not well, and influence its effect.

 

 

 

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

 

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmissionFactory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

 

 

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmissionFactory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

Factory prices 1kv single core flame-retardant low voltage cable ,11kv MV XLPE cable ,33kv underground cable for transmission

Contact Supplier

Ms. Jane Yin International Trade Chat Now
Telephone
86-531-68656606
Mobile
86-15169183960
Fax
86-531-68656606
Address
Jinghe Industrial Zone, Hejian City Cangzhou,Hebei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~