No Halogen Fire Retardant Fire Resisting Xlpe Power Cable 3500V / 5min Without Puncture
Negotiable /Meter
Min.Order:500 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
house wires/high voltage cable/copper cable /pvc insulated cable/copper conductor/baofeng calble
house wire/high voltage cable/copper cable /pvc insulated cable/copper conductor/baofeng cale
house wires/low voltage cable/copper cable /pvc insulated cable/copper conductor/baofeng calble
house wire/high voltage cable/copper cable /pvc insulated cable/copper conductor
Application
This product is suitable for AC 0.6/1kV of power frequency or below equipment, fire hazard and fire fighting equipment, emergency passage transportation, lighting, etc emergency facilities where the power supply requires fireproof fields. Particularly it is suitable for subway, under-ground shop, high-rise, intelligence communication building, power station and so on fields with high safe requirements.
Product characteristics
1. With all characteristics of no halogen low smoke fire retardant power cable.
2. Burn at 800°C and below flame environment, can guarantee to electrify over 180 min. compared with ordinary cable, its time of fireproof can prolong two times, the safety is better.
Type and Specifications
Type | No. of Core | Nom. area Cross-Section area mm2 |
WDZN-YJY WDZN-YJY23 WDZN-YJY33 | 1 | 2.5~1000 |
2,3,4,5 | 4~240 | |
Note: When 1-core cable needs to armor, the cross section should not be less than 10mm2. Meanwhile it should use non-magnetic material or reduce magnetic loss structure. |
Type | Designation |
WDZN-YJY | Copper-conductor XLPE insulated PO sheathed no halogen low smoke fire retardant fire resisting power cable |
WDZN-YJY23 | Copper-conductor XLPE insulated steel tape armored PO sheathed no halogen low smoke fire retardant fire resisting power cable |
WDZN-YJY33 | Copper-conductor XLPE insulated fine steel wire armored PO sheathed no halogen low smoke fire retardant fire resisting power cable |
Construction
1. Conductor
2. Fire-resisting insulation layer
3. XLPE insulation
4. Insulation
5. Inner covering
6. Armor
7. Oversheath
Main performance
1. Combustion property
(1) Halogen gases releasing amount test, pH value≥4.3,electrical conductivity≤10ms/mm
(2) Cable combustion smoking amount test, light transmittance≥60%
(3) Cable fireproof test: pass B kind fireproof test specified in IEC6033 and GB12666.6
(4) Cable fire retardant test: pass bundling(or B kind or C kind)combustion test specified in IEC 60332 and GB12666.5
2. Electric property
(1) D.C. conductor resistance complies with the stipulations of the nether table;
(2) Working frequency voltage test for cable with 3500V/5min without puncture.
(3) Constant of insulation resistance at 90°C should not more than 3.67 MΩ·Km.