factory and R&D center based copper conductor control cable 6mm2
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
factory and R&D center based copper conductor control cable 6mm2
1.Standard
The control cable can be produced according to the standard GB9330-1988,IEC60227(60502,60332),DIN, BS, and our factory can also manufacture the cables in accordance with other standards.
2.Service Conditions
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2) The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
3.Type& Specification
Type | Name | Section Area(mm2) | No. of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable | 0.5 0.75 1.0 | 4-61 |
|
|
| 1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
TYPE | NAME | Section Area(mm 2 ) |
|
| |||||
| 0.75 | 1 | 1.5 | 2.5 | 4 | 6 | 10 |
| |
| No. of Core | Application Site | |||||||
KVV | Copper Conductor, PVC Insulated and Sheathed Control Cable | 2-48 | 2-14 | 2-10 | Permanent installation indoors, in cable ditches or pipes | ||||
ZR-KVV | Flame Retardant Copper Conductor, PVC Insulated and Sheathed Control Cable | ||||||||
NH-KVV | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed Control Cable | ||||||||
KVVP | Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable | 2-48 | 2-14 | 2-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required | ||||
ZR-KVVP | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable | ||||||||
NH-KVVP | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding Shielded Control Cable | ||||||||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 4-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches or pipes where shielding is required | ||||
ZR-KVVP2 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | ||||||||
NH-KVVP2 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | ||||||||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable | 7-48 | 4-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches, directly buried, Be able to withstand stronger external mechanical force | |||
ZR-KVV22 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable | ||||||||
NH-KVV22 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Steel tape Armored Control Cable | ||||||||
KVV32 | Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | 19-61 | 7-48 | 4-14 | 4-10 | Permanent installation indoors, in cable ditches, vertical shaft Be able to withstand stronger external mechanical force | |||
ZR-KVV32 | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | ||||||||
NH-KVV32 | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable | ||||||||
KVVR | Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | 4-48 | - | - | Installation indoors where flexibility and movability are required | ||||
ZR-KVVR | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | ||||||||
NH-KVVR | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Flexible Control Cable | ||||||||
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | 4-16 | 4-48 | - | - | Installation indoors where flexibility shielding and movability are required | |||
ZR-KVVRP | Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | ||||||||
NH-KVVRP | Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |