Meanwell 12~18W AC-DC Single Output Interchangeable Wall-mounted type 7.5v switching power supply
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
ORDER NO. | GE18I07-P1J | |
OUTPUT | SAFETY MODEL NO. | FRA018-S07-I |
DC VOLTAGE Note.2 | 7.5V | |
RATED CURRENT | 1.73A | |
CURRENT RANGE | 0 ~ 1.73A | |
RATED POWER | 13W | |
RIPPLE & NOISE (max.) Note.3 | 75mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±5.0% | |
LINE REGULATION Note.5 | ±1.0% | |
LOAD REGULATION Note.6 | ±5.0% | |
SETUP, RISE, HOLD UP TIME | 4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 135 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 79% | |
AC CURRENT | 0.7A / 100VAC 0.4A / 230VAC | |
INRUSH CURRENT (max.) | COLD START 40A / 100VAC 80A / 230VAC | |
LEAKAGE CURRENT(max.) | 0.25mA / 240VAC | |
PROTECTION | OVERLOAD | 110 ~ 200 %rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 115% ~ 135% | |
Protection type : Clamp by zener diode | ||
ENVIRONMENT | WORKING TEMP. | -10 ~ +50°C(Refer to "Derating Curve") |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C( 0~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | UL60950-1, CSA C22.2, TUV EN60950 -1, CCC GB4943 approved |
WITHSTAND VOLTAGE | I/P-O/P:4242VDC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms /500VDC/25°C/70% RH | |
EMC EMISSION | Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | |
OTHERS | LIFE | 2 years : 100% load 30°C, 8 hours / day |
MTBF | 100Khrs min. MIL-HDBK-217F(25°C) | |
DIMENSION | 81*43*40.5mm (L*W*H) | |
PACKING | 134g ; 60pcs / 12.32kg / CARTON | |
CONNECTOR | PLUG | Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requested |
CABLE | See page2 | |
NOTE | 1.All parameters are specified at 115VAC input, rated load, 25°C 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load 7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug. |