Meanwell 12v 1a switching power supply/10 ~ 12W AC-DC Single Output Wall-mounted type/high frequency switching power supply
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
ORDER NO. | GS12E12-P1I | |
OUTPUT | SAFETY MODEL NO. | GS12E12 |
DC VOLTAGE | 12V | |
RATED CURRENT | 1.0A | |
CURRENT RANGE | 0 ~ 1.0A | |
RATED POWER | 12W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | |
LINE REGULATION Note.4 | ±1.0% | |
LOAD REGULATION Note.5 | ±3.0% | |
SETUP, RISE, HOLD UP TIME | 500ms, 20ms, 30ms/230VAC 500ms, 20ms, 10ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 135 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 78.5% | |
AC CURRENT | 0.31A / 115VAC 0.16A / 230VAC | |
INRUSH CURRENT (max.) | COLD START 25A / 115VAC 45A / 230VAC | |
LEAKAGE CURRENT(max.) | 0.25mA / 240VAC | |
PROTECTION | OVERLOAD | >105 %rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 115% ~ 135% | |
Protection type : Clamp by zener diode | ||
OVER TEMPERATURE Note.6 | U1 Tj 140°C typically (U1) Detect on main control IC | |
Protection type : Shut down o/p voltage, recoversautomatically after temperature goes down | ||
ENVIRONMENT | WORKING TEMP. | 0 ~ +50°C(Refer to "Derating Curve") |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C( 0~ 40°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | UL60950-1, CSA22.2, BSMI CNS14336 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms /500VDC/25°C/70% RH | |
EMC EMISSION | Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B | |
OTHERS | MTBF | 1414.6Khrs min. MIL-HDBK-217F(25°C) |
DIMENSION | 65*47*26.5mm (L*W*H) | |
PACKING | 0.15Kg ; 100pcs / 16Kg / CARTON | |
CONNECTOR | PLUG | Standard type P1I: 2.1 * 5.5 * 9.5mm turning fork type, center positive for stock ; Other type available by customer requested |
CABLE | Standard type UL1185 6ft (4FT only for 5V output) for stock ; Other type available by customer requested | |
NOTE | 1.All parameters are specified at 115VAC input, rated load, 25°C 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 10% to 100% rated load. 6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specificationprovided by the IC manufacturer. |