Meanwell GS220A20-R7B 220W 20v 11a desktop ac-dc adaptor adaptor switching 20v 11a
USD $1 - $10 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
Meanwell 120W AC-DC Single Output Desktop 120w switching power supply/20v 6a switching power supply
Meanwell 120W AC-DC Single Output Desktop ac switching power supply
Meanwell 40W AC-DC Single Output Desktop ac/dc switching power supply
Meanwell 20~25W AC-DC Single Output Desktop 20w switching power supply
ORDER NO. | GS220A20-R7B | |
OUTPUT | SAFETY MODEL NO. | GS220A20 |
DC VOLTAGE Note.2 | 20V | |
RATED CURRENT | 11A | |
CURRENT RANGE | 0 ~ 11A | |
RATED POWER(max.) | 220W | |
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±4.0% | |
LINE REGULATION Note.5 | ±1.0% | |
LOAD REGULATION | ±4.0% | |
SETUP, RISE TIME Note.7 | 2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 20ms / 230VAC 20ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE Note.8 | 90 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.91 / 230VAC PF>0.98 / 115VAC at full load | |
EFFICIENCY (Typ.) | 92% | |
AC CURRENT(Typ.) | 4A / 115VAC 2A / 230VAC | |
INRUSH CURRENT (max.) | 120A / 230VAC | |
LEAKAGE CURRENT(max.) | 1.5mA / 240VAC | |
PROTECTION | OVERLOAD | 105 ~ 135%rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 105 ~ 135%rated output voltage | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | 95°C ±5°C (TSW1) detect on heatsink of power transistor | |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||
ENVIRONMENT | WORKING TEMP. | -30 ~ +60°C(Refer to "Derating Curve") |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC (Note. 6) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1, BSMI CNS14336, J60950-1(except for 48V) approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms /500VDC/25°C/70% RH | |
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 class B / CISPR22 class B, CNS13438 class B | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | |
OTHERS | MTBF | 191.3K hrs min. MIL-HDBK-217F(25°C) |
DIMENSION | 210*85*46mm (L*W*H) | |
PACKING | 1.1Kg; 12pcs/14.2Kg/0.73CUFT | |
CONNECTOR | PLUG | See page 2 ; Other type available by customer requested |
CABLE | See page 2 ; Other type available by customer requested | |
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. 7 Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. Derating may be needed under low input voltages. Please check the derating curve for more details. |