Meanwell 280W AC-DC Single Output Desktop 280w switching power supply
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
Meanwell GS220A20-R7B 220W 20v 11a desktop ac-dc adaptor adaptor switching 20v 11a
Meanwell 120W AC-DC Single Output Desktop 120w switching power supply/20v 6a switching power supply
Meanwell 120W AC-DC Single Output Desktop ac switching power supply
Meanwell 40W AC-DC Single Output Desktop ac/dc switching power supply
Meanwell 20~25W AC-DC Single Output Desktop 20w switching power supply
ORDER NO. | GS280A15-C4P | |
OUTPUT | SAFETY MODEL NO. | GS280A15 |
DC VOLTAGE Note.2 | 15V | |
RATED CURRENT | 16A | |
CURRENT RANGE | 0 ~ 16A | |
RATED POWER(max.) | 240W | |
RIPPLE & NOISE (max.) Note.3 | 120mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±5.0% | |
LINE REGULATION Note.5 | ±1.0% | |
LOAD REGULATION | ±5.0% | |
SETUP, RISE TIME Note.6 | 2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 16ms / 230VAC 16ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE Note.7 | 90 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.95 / 230VAC PF>0.98 / 115VAC at full load | |
EFFICIENCY (Typ.) | 89.5% | |
AC CURRENT(Typ.) | 3A / 115VAC 1.5A / 230VAC | |
INRUSH CURRENT (max.) | 120A / 230VAC | |
LEAKAGE CURRENT(max.) | 1.5mA / 240VAC | |
PROTECTION | OVERLOAD | 105 ~ 135%rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 105 ~ 135%rated output voltage | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | 100°C ±10°C (RTH2) | |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||
ENVIRONMENT | WORKING TEMP. | -30 ~ +60°C(Refer to "Derating Curve") |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~40°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC (Note. 8) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms /500VDC/25°C/70% RH | |
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | |
OTHERS | MTBF | 173.6Khrs min. MIL-HDBK-217F(25°C) |
DIMENSION | 220*95*46mm (L*W*H) | |
PACKING | 1.25Kg; 12pcs/16Kg/1.27CUFT | |
CONNECTOR | PLUG | See page 2 ; Other type available by customer requested |
CABLE | See page 2 ; Other type available by customer requested | |
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7 Derating may be needed under low input voltages. Please check the derating curve for more details. 8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. |