Liquid circulation system Industrial using low temperature freezer cryogenic freezing CDLJ-4W
Negotiable /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Applied in chemical, pharmaceutical ultra-low temperature freezer CDLJ-10W
Blast freezers applied in chemical, pharmaceutical low temperature freezer LJ-60W
With good quality Cooling and heating thermostatic applied to reactor from -100 up to 100 degree
TCU applied to glass reactor temperature range from -50 to 250 degree
Air cooling chiller of cooling and heating machine temperature range from -30 up to 180 degree
Medium-sized low-temperature freezer, refrigeration temperature range from -5 ℃ ~ -150 ℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.
Detaile:
1.Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature.
2.Adopt environmental protection refrigerants
3.Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK. Bitzer, Copeland, Hanbell, fusheng; Plate heat exchanger, Small volume, High efficiency.
4.Top imported cold controller(DANFOSS pressure controller, balance valve, expansion valve, solenoid valve, filter drier, Emerson oil separator, ALCO liquid mirror, check valve, etc.)
5.Generator cooling water circuit use intermediate heat exchanger,improve system reliability and safety.
6.DANFOSS electronic expansion valve, high precision control;
7.Adopt Siemens PLC S7-200/300, LNEYA touch screen, automatic control,temperature curve display, temperature record U disk, fault alarm;
8.Large cooling capacity adopts semi-hermetic screw compressor,electronic expansion valve control, high efficiency and energy saving;
9.Offer machine installation and system test, users only need to finish the installation of refrigerant and cooling water;
10.Factory testing: each refrigerating unit is on load test of not less than 12 hours in the factory.
Technical Parameters:
Product Name | Ultra-low Temperature Freezer | |||
Model | CDLJ-2W | CDLJ-3W | CDLJ-4W | CDLJ-6W |
Temperature Range ℃ | -115°C~ -50°C | |||
Cooling Capacity At -90°C | 3kW | 4.5kW | 6kW | 9kW |
2580Kcal/h | 3870Kcal/h | 5160Kcal/h | 7740Kcal/h | |
Cooling Capacity At -110°C | 2kW | 3kW | 4kW | 6kW |
1720Kcal/h | 2580Kcal/h | 3440Kcal/h | 5160Kcal/h | |
Circulation Pump | 6.6m³/h 2.5bar max | 6.6m³/h 2.5bar max | 6.6m³/h 2.5bar max | 15m³/h 2.5bar max |
Inlet & outlet connection size | DN-25 PN-10 | DN-25 PN-10 | DN-25 PN-10 | DN-32 PN-10 |
Water-cooled type W (cooling water at 30℃) | 10m³/h | 14m³/h | 20m³/h | 25m³/h |
Cold storage tank (optional) | 100L | 150L | 150L | 250L |
Expansion tank (standard) | 50L | 75L | 100L | 150L |
Compressor | Standard:Copeland | |||
Operation Panel | 7-inch color touch screen display, temperature curve record, data export to excel format. | |||
Control System | Standard: Single-chip microcomputer controller; Stepping control; Set temperature difference of refrigeration on & off. Optional: SIEMENS S7-200PLC&Module | |||
Closed | The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | |||
Circulation pump | Standard:Direct type magnetic pump Optional: Increase the pipeline magnetic pump pressure in the pipeline | |||
Evaporator | Standard:Direct type magnetic pump Optional: Increase the pipeline magnetic pump pressure in the pipeline | |||
Condenser | Shell and tube type water cooled condenser | |||
Intermediate heat exchanger | KAORI Plate heat exchanger | |||
Dry Filter | Emerson | |||
Drying filter core | Emerson | |||
Expansion tank | Emerson | |||
FDF | Emerson | |||
Oil separator
| Emerson | |||
Pressure protector | Emerson | |||
Reservoir
| Standard:RSP Optional:Emerson | |||
Sight glass | Standard: SANHUA Optional:Danfoss | |||
Refrigeration ball valve | Standard: SANHUA Optional:Danfoss | |||
Electric | Schneider AC contactor, Schneider intermediate relay | |||
Refrigerant | R404A | |||
Secondary refrigerant | No corrosive liquid, ethanol water, ethylene glycol aqueous solution, heat transfer oil etc. | |||
Safety protection | High pressure protect; Water supply cut-off protection; Over-current protection; Leakage protection; Sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. muti-safety protection. | |||
Level Indicator | Adpot glass liquid level indication | |||
Piping material | SUS304 | |||
Expansion tank material | SUS304 | |||
Case material | Steel channel + Square tube + Cold-rolled blanking plate painting | |||
Power | 380V 50HZ 14kW max | 380V 50HZ 18kW max | 380V 50HZ 30kW max | 380V 50HZ 43kW max |
Product size | 205*145*175 | 205*145*175 | 235*145*175 | 300*150*205 |
HP | 15HP | 20HP | 35HP | 50HP |
dB | 75DB | Within 80dB |
Wuxi Guanya Refrigeration Technology Co., Ltd. Specialized in rerfigeration equipment, ultra-low temperature freezer, cooling and heating temperature control system, heating circulation system, explosion-proof electric equipment. Automatic integrated disparate control system, laboratory apparatus. We are the technology leader for high precision thermoregulation solutions in Research and Development Industry. Our products ensure precise temperature control throughout the whole world in laboratories, pilot plants and production processes. Our product range offers temperature control solutions for applications from -152 to +350℃.
We make market and user need oriented products, focusing on science and technology applying international advanced technology, endlessly get rid of the stale and bring forward the fresh following the market step & meet market demand. The company always insists on standardised management in accordance with ISO9001-2008 international quality certification requirement from product design, purchase and selection of components, to production process flow, packaging and transportation etc, try to keep improving products, and keep reasonable price and satisfactory service.
Development history
In 2006 Start production of refrigeration and heating system equipments.
In 2007 Developed the first generation of refrigeration and heating thermostat and establish the LNEYA CO., LTD.
In 2008 Developed the first generation of refrigeration and dynamic temperature control system.
In 2009 Developed the second generation of refrigeration and heating thermostat.
In 2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.
Developed the second generation of refrigeration and heating dynamic temperature control system.
Developed the refrigeration and heating dynamic temperature control system & low temperature freezer for industry use.
In 2011 Developed new technology with single compressor having multiple circulation systems (can reach to -80 degree with single compressor)
Upgraded the second generation of refrigeration and heating dynamic temperature control system.
In 2012 Single compressor having multiple circulation systems is applied in production of SUNDI-4, SUNDI-5, SUNDI-6, and SUNDI-7, SUNDI-8 and LT series.
Upgraded the second generation of refrigeration and heating dynamic temperature control system for the second time and developing the third generation of refrigeration and heating dynamic temperature control system.
In 2013 Developed new product one operating multi refrigeration and heating temperature control system(the third generation of refrigeration and heating dynamic temperature control system).At the same time testing the large capacity of ultra-low temperature freezer.
In 2014 Developed with large capacity of ultra-low temperature freezer which used for industrial production,new goods will be research.And it will be launched in the market soon........