Heating unit for Laboratory Research from 50 up to 200 degree
USD $1,000 - $50,000 /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Industry and laboratory refrigerating treatment applied to glass reactor from -90 up to 250 degree
Laboratory cooling unit apply to glass reactor temperature range from -30 up to 180 degree
Low temperature refrigerator applied to reactor temperature range from - 25 up to 200 degree
Thermostatic cooling unit applied to reactor temperature range from - 25 up to 200 degree
Chiller with good quality temperature range from 5~35 degree
Heating Temperature Control systems
Technical Parameters:
Model | UC-A1520 | UC-A2520 | UC-A3820 | UC-A6020 | UC-A9520 | UC-A13020 | UC-A20020 | |
Temperature range ℃ | 50℃~200℃ | |||||||
Controller | PID adaptive controller | |||||||
Temp. Control optional | Heat-conducting medium outlet temp. control | |||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | |||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | |||||||
Temp. accuracy | ±0.5℃ | ±0.5℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±2℃ | |
Heating power | 15kW | 25kW | 38kW | 60kW Divide to two groups heating | 95kW Divide to three groups heating | 130kW Divide to three groups heating | 200kW Divide to four groups heating | |
Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃), it can close the most of heating duty and leave the next group to be PID fuzzy control. | ||||||||
Cooling capacity | 300℃ |
|
|
|
|
|
|
|
200℃ | 15kW | 25kW | 38kW | 60kW | 95kW | 130kW | 200kW | |
100℃ | 12kW | 20kW | 30kW | 48kW | 76kW | 100kW | 160kW | |
65℃ | 5kW | 8.5kW | 12kW | 19kW | 30kW | 40kW | 64kW | |
| There is a heat exchanger in the system and it needs water to cool. Open the water valve automatically according to demand. | |||||||
Circulation pump | Max50L/min 2.5BAR | Max110L/min 2.5BAR | Max110L/min 2.5BAR | Max250L/min 2.5BAR | Max250L/min 2.5BAR | Max400L/min 2.5BAR | Max400L/min 2.5BAR | |
Expansion tank volume | 35L | 65L | 90L | 160L | 240L | 300L | 500L | |
Heater | Orient electric heater | |||||||
Independent temperature limiter | LNEYA | |||||||
Cooler | Plate heat exchanger | |||||||
Operation panel | Display setting temperature and testing temperature; Touch screen display | |||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload | |||||||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | |||||||
Connection size | DN-25 | DN25 | DN25 | DN40 | DN40 | DN-50 | DN-50 | |
Dimension | 600*600*1250 | 600*600*1250 | 1200*750*1100 | 1200*750*1100 | 1400*750*1300 | 1400*750*1300 | 1500*850*1450 | |
Weight | 100kg | 130kg | 170kg | 285kg | 318kg | 450kg | 685kg | |
Power | AC380V 50HZ 15.7kW (max) | AC380V 50HZ 26.5kW (max) | AC380V 50HZ 39.5k (max) | AC380V 50HZ 63kW (max) | AC380V 50HZ 98kW (max) | AC380V 50HZ 135.5kW (max) | AC380V 50HZ 206kW (max) | |
Case material | Cold rolled steel painting | |||||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | |||||||
Optional | SUS 304 SUS 304 case material | |||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Model | UC-A1530 | UC-A2530 | UC-A3830 | UC-A6030 | |
Temperature range ℃ | 50℃~300℃ | ||||
Controller | PID adaptive controller | ||||
Temp. Control optional | Heat-conducting medium outlet temp. control | ||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||
Temp. accuracy | ±0.5℃ | ±1℃ | ±1℃ | ±1℃ | |
Heating power | 15kW | 25kW | 38kW | 60kW Divide to two groups heating | |
Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃), it can close the most of heating duty and leave the next group to be PID fuzzy control. | |||||
Cooling capacity | 300℃ | 15kW | 25kW | 38kW | 60kW |
200℃ | 13kW | 22kW | 32kW | 50kW | |
100℃ | 10kW | 17kW | 27kW | 40kW | |
65℃ | 4kW | 6kW | 11kW | 16kW | |
| There is a heat exchanger in the system and it needs water to cool. Open the water valve automatically according to demand. | ||||
Circulation pump | Max50L/min 2.5BAR | Max110L/min 2.5BAR | Max110L/min 2.5BAR | Max250L/min 2.5BAR | |
Expansion tank volume | 50L | 80L | 120L | 220L | |
Heater | Orient electric heater | ||||
Independent temperature limiter | LNEYA | ||||
Cooler | Plate heat exchanger | ||||
Operation panel | Display setting temperature and testing temperature; Touch screen display | ||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload | ||||
Closed | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||
Connection size | DN-25 | DN-25 | DN-25 | DN-40 | |
Dimension | 600*600*1250 | 600*600*1250 | 1200*750*1100 | 1200*750*1100 | |
Weight | 115kg | 155kg | 195kg | 320kg | |
Power | AC380V 50HZ 16kW (max) | AC380V 50HZ 26.5kW (max) | AC380V 50HZ 39.5k (max) | AC380V 50HZ 63kW (max) | |
Case material | Cold rolled steel painting | ||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | ||||
Optional | SUS 304 SUS 304 case material | ||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |