Cooling thermostats unit applied to glass reactor from -90 up to 250 degree
Cooling thermostats unit applied to glass reactor from -90 up to 250 degree
Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

USD $1,000 - $50,000 /Set

Min.Order:1 Set

Supply Ability:
10 Set / Sets per Month
Port:
Shanghai

Quick Details View All >

Brand Name:
LNEYA
Model Number:
SUNDI-9A15W
Place of Origin:
Jiangsu, China

Wuxi Guanya Refrigeration Tech Co., Ltd.

Business Type: Manufacturer,Trading Company
Wuxi Jiangsu China
Main Products: Dynamic Temperature Control Systems ,Chiller ,Freezer ,test chamber ,Refrigerated heating circulator

Product Details

Dynamic Temperature Control systems

 

Cooling And Heating Temperature Control systems

 

 Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

 

 

 

Product Description

Typical Applications

Reactor Systems Autoclaves
Pilot Systems
Mini Plant Systems
Scale up for Operational Development
Double wall reactors
Advanced-Flow Reactors
Distillation Systems
Material Testing
Combinational Chemistry
Semiconductor Industry
Vacuum Chambers

Advantages & Functions

Working temperatures from -100℃ to +350℃
Previously unachievable performa

Intelligent temperature control
Maximum process stability and reproducibility
Adop plate heat exchager,Pipeline heating,

the fastest heating and cooling rates.
High cooling power

Large temperature range without fluid change
Closed system,extend thermal fluid lifetime
Incredibly compact
7-inch,10-inch color TFT touch screen display
Comprehensive warning and safety functions
Rapid cooling down from high temperature

Use magnetic drive pump,solve the circulation pump leakage

Structure design

 

Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

 

A fully closed piping design, high efficiency plate heat exchanger used to reduce the 

demand for the thermal fluid utilization while providing the system to achieve the rapid

 ups and downs in temperature The whole system is a closed liquid circulation system 

with the expansion of container, expansion of the container and the liquid circulation is 

adiabatic, and do not participate in liquid circulation, only mechanical connection, no

matter the temperature is a high temperature or low temperature, the tank temperature

is limited to 60℃. Therefore, during the process the risk of imbibing and volatilization

of the heat conducting medium is reduced. There following advantages for the user.

 Only the heat conduction medium in the expansion container touches the oxygen in the air. 

(The container temperature is limited to 60℃).

 No volatilization of the heat conducting medium at high temperature.

 No need to change the heat conducting medium. Continuous control of the temperature 

 of the below range can be done without rising the pressure: -80℃~190℃, -70℃~220℃,

 -88℃~170℃, -55℃~250℃, -30℃~300℃.

Display funcation

 The Refrigeration system displays various information on the touch screen.

Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

1. Displays all the kind of process control temperatures.

2. Shows the liquid level of the heat conducting medium in the expansion vessel.

3. Shows indication for refrigeration system working.

4. Shows indication for heater working.

5. Shows indication for circulation pump working.

6. Displays the temperature control (materials temperature control pattern, heat

conducting medium temperature control ).

7. The temperature upper limit, lower limit control can be set.

8. The temperature difference between jacket & reactor material can be set.

9. Shows the alarm to add the liquid when it is empty.

10. The refrigeration compressor can be set to operate manually or automatically.

11. Simple Menu to use. 

    

Process Control Schematic diagram

Change the control settings of the method, the response as soon as possible in the 

process of thesystem lags behind, be the smallest system overshoot. Controlled by 

two PID (PID is a variable in each group) control loop structure, known as the two 

sets of control loops: the main circuit and from the circuit, the main control loop 

from the loop output as the settings. 

System with feedforward with PV, the master PID loop operation results of the PV 

output and feedforward signals as the composite of the settings from the control loop, 

through such control of the temperature gradient to ensure the accuracy of temperature

 control system.

High repetative of tempeature control effect 

Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.

Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

 

Circulation Pump

High temperature resistant low temperature magnetic drive pump or a leak-free high and

low temperature shield-driven pump, reduce the risk of system leakage. At the same time

the system has the advantages of low noise and big traffic flow.

 

Connecting Pipe

 

Cooling thermostats unit applied to glass reactor from -90 up to 250 degree

LNEYA Dynamic Temperature Control systems in practice

In comparison to other thermal control systems, Dynamic Temperature Control systems 

differ sometimes considerably in their thermodynamic characteristics. In practice Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorther heating and cooling times, better stability and reproducibility through the entire process 

chain, greater safety for expensive glass reactors and the contained substances, together 

with simple and easy operation.

 

Heat Conduction Medium

It is important to choose the suitable heat conduction medium, to make sure that system 

works stably.To choose the suitable medium according to the working temperature of the system is essential.

The package kinds of LNEYA heat conduction medium are 10L, 25L, 30L, 200L. when ordering the heat conduction medium, the heat conduction medium for constant temp

control system, channel, and external circulation equipments.

Cooling thermostats unit applied to glass reactor from -90 up to 250 degree 

Technical Parameters:

 

Model

SUNDI-9A15W

SUNDI-9A25W

SUNDI-9A38W

SUNDI-9A60W

SUNDI-10A15W

SUNDI-10A25W

SUNDI-10A38W

Temperature range ℃

-90℃~250℃

Controller

Feed forward PID +Our special dynamic control calculation, PLC controller

Communication

MODBUS RTU Protocol, RS 485 Interface

Temp. control

Process temperature control mode

Program Editor

20 programs, each program can edit 45 steps.

Temperature feedback

Heat-conducting medium feedback PT100, (oil outlet temperature,

oil inlet temperature and heater temperature) ,Three temperature measuring points.

Process Temperature

feedback

Raw material process feedback PT100 or 4~20mA input (optional)

Process Temp. accuracy

±1℃

±1℃

±1℃

±1℃

±1℃

±1℃

±1℃

Heating power

15kW

25kW

38kW

60kW

15kW

25kW

38kW

Cooling capacity

250℃

15kW

25kW

38kW

60kW

15kW

25kW

38kW

100℃

15kW

25kW

38kW

60kW

15kW

25kW

38kW

20℃

15kW

25kW

38kW

60kW

15kW

25kW

38kW

-20℃

15kW

25kW

38kW

60kW

15kW

25kW

38kW

-40℃

12kW

20kW

31kW

48kW

15kW

25kW

38kW

-60℃

6kW

10kW

16kW

23kW

9kW

15kW

22.8kW

-80℃

2.1kW

3.4kW

5.3kW

11.5kW

5kW

8kW

12.5kW

-90℃

 

 

 

 

3kW

4.8kW

7.5kW

Circulation pump

Max110L/min

2.5BAR

Max150L/min

2.5BAR

Max250L/min

2.5BAR

Max250L/min

2.5BAR

Max110L/min

2.5BAR

Max150L/min

2.5BAR

Max250L/min

2.5BAR

Compressor

Bock

Bock

Bock

Bock

Bock

Bock

Bock

Evaporator

KAORI Plate heat exchanger

Oil separator

Emerson

Expansion valve

Emerson

Operation panel

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch,

overload relay, thermal protection device, liquid low level protection,

high temperature protection and temperature fault protection.

Closed
circulation system

The whole system is full closed circulation, there is no oil mist at high temperature

and no water vapor at low temperature, pressure do not rise up when system is running.

The system will supplement oil automatically at low temperature.

Refrigerant

R-404A R23 R14 mixed Refrigerant

Connection size

DN25 PN10

DN32 PN10

DN40 PN10

DN40 PN10

DN25 PN10

DN32 PN10

DN40 PN10

 

Water-cooled type W

(cooling water at 25℃)

 

8m³/h

1.5bar~4bar

12m³/h

1.5bar~4bar

20m³/h

1.5bar~4bar

30m³/h

1.5bar~4bar

12m³/h

1.5bar~4bar

20m³/h

1.5bar~4bar

30m³/h

1.5bar~4bar

water-cooled condenser

Shell and tube exchanger(standard)

Dimension

1500*1000*1750

1800*1200*1750

2050*1450*1750

2300*1450*1850

1800*1200*1750

2250*1450*1750

2300*1450*1850

Weight

780kg

1150kg

1480kg

1950kg

950kg

1300kg

1700kg

Power

AC380V 50HZ

29kW (max)

AC380V 50HZ

47kW (max)

AC380V 50HZ

67kW (max)

AC380V 50HZ

106kW (max)

AC380V 50HZ

34kW (max)

AC380V 50HZ

 53kW (max)

AC380V 50HZ

75kW (max)

Case material

SUS 304

SUS 304

SUS 304

SUS 304

SUS 304

SUS 304

SUS 304

Optional

Optional Ethernet interface, configure the computer operating software

Optional

Water condenser use plate heat exchanger (request for high quality water)

Optional power

440V~480V 60HZ  three-phase

 Cooling thermostats unit applied to glass reactor from -90 up to 250 degreeCooling thermostats unit applied to glass reactor from -90 up to 250 degree

Contact Supplier

Ms. Lisa Li engineer Chat Now
Telephone
0086-510-82321181
Mobile
0086-17715697019
Fax
0086-510-82303782
Address
No.10, Zhenfa No.1 Road, New district, Wuxi, Jiangsu, China Wuxi,Jiangsu

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Chemicals > Lab Supplies > Laboratory Thermostatic Devices
Categories
Hi~