High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree
High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree
High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree
High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

USD $9,400 - $9,500 /Set

Min.Order:1 Set

Supply Ability:
200 Set / Sets per Month
Port:
shanghai

Quick Details View All >

Type:
Other, Temperature control system
Place of Origin:
Jiangsu, China
Brand Name:
LNEYA
Model Number:
SUNDI-535WN
Certification:
CE, Other, CE, ISO
After-sales Service Provided:
Overseas third-party support available

Wuxi Guanya Refrigeration Tech Co., Ltd.

Business Type: Manufacturer,Trading Company
Wuxi Jiangsu China
Main Products: Dynamic Temperature Control Systems ,Chiller ,Freezer ,test chamber ,Refrigerated heating circulator

Product Details

 

 

Dynamic Temperature Control systems

SUNDI -50℃ ~ 250℃ Parameter

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

Product Description

Typical Applications

Reactor Systems Autoclaves
Pilot Systems
Mini Plant Systems
Scale up for Operational Development
Double wall reactors
Advanced-Flow Reactors
Distillation Systems
Material Testing
Combinational Chemistry
Semiconductor Industry
Vacuum Chambers

Advantages & Functions

Working temperatures from -100℃ to +350℃
Previously unachievable performa

Intelligent temperature control
Maximum process stability and reproducibility
Adop plate heat exchager,Pipeline heating,

the fastest heating and cooling rates.
High cooling power

Large temperature range without fluid change
Closed system,extend thermal fluid lifetime
Incredibly compact
7-inch,10-inch color TFT touch screen display
Comprehensive warning and safety functions
Rapid cooling down from high temperature

Use magnetic drive pump,solve the circulation pump leakage

Structure design

 

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

 

A fully closed piping design, high efficiency plate heat exchanger used to reduce the

demand for the thermal fluid utilization while providing the system to achieve the rapid

ups and downs in temperature The whole system is a closed liquid circulation system

with the expansion of container, expansion of the container and the liquid circulation is

adiabatic, and do not participate in liquid circulation, only mechanical connection,

no matter the temperature is a high temperature or low temperature, the tank

temperature is limited to 60℃. Therefore, during the process the risk of imbibing

and volatilization of the heat conducting medium is reduced. There following

advantages

for the user.

 Only the heat conduction medium in the expansion container touches the oxygen

 in the air. (The container temperature is limited to 60℃).

 No volatilization of the heat conducting medium at high temperature.

 No need to change the heat conducting medium. Continuous control of the temperature 

 of the below range can be done without rising the pressure: -80℃~190℃, -70℃~220℃,

 -88℃~170℃, -55℃~250℃, -30℃~300℃.

Display funcation

 The Refrigeration system displays various information on the touch screen.

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

1. Displays all the kind of process control temperatures.

2. Shows the liquid level of the heat conducting medium in the expansion vessel.

3. Shows indication for refrigeration system working.

4. Shows indication for heater working.

5. Shows indication for circulation pump working.

6. Displays the temperature control (materials temperature control pattern, heat

conducting medium temperature control ).

7. The temperature upper limit, lower limit control can be set.

8. The temperature difference between jacket & reactor material can be set.

9. Shows the alarm to add the liquid when it is empty.

10. The refrigeration compressor can be set to operate manually or automatically.

11. Simple Menu to use. 

    

Process Control Schematic diagram

Change the control settings of the method, the response as soon as possible in the 

process of the system lags behind, be the smallest system overshoot. Controlled by 

two PID (PID is a variable in each group) control loop structure, known as the two 

sets of control loops: the main circuit and from the circuit, the main control loop from 

the loop output as the settings. 

System with feedforward with PV, the master PID loop operation results of the PV 

output and feedforward signals as the composite of the settings from the control loop, 

through such control of the temperature gradient to ensure the accuracy of temperature 

control system.

High repetative of tempeature control effect 

Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

 

Circulation Pump

High temperature resistant low temperature magnetic drive pump or a leak-free high

and low temperature shield-driven pump, reduce the risk of system leakage. At the

same time the system has the advantages of low noise and big traffic flow.

 

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree 

Connecting Pipe

 

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

LNEYA Dynamic Temperature Control systems in practice

In comparison to other thermal control systems, Dynamic Temperature Control systems

differ sometimes considerably in their thermodynamic characteristics. In practice Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorther heating and cooling times, better stability and reproducibility through the entire process

chain, greater safety for expensive glass reactors and the contained substances, together

with simple and easy operation.

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

 

Heat Conduction Medium

It is important to choose the suitable heat conduction medium, to make sure that

system works stably.To choose the suitable medium according to the working

temperature of the system is essential.

The package kinds of LNEYA heat conduction medium are 10L, 25L, 30L, 200L.

when ordering the heat conduction medium, the heat conduction medium for constant

temp       control system, channel, and external circulation equipments.

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree 

Technical Parameters:

 

 

Model

SUNDI-525W N

 

SUNDI-535WN

 

SUNDI-555W

SUNDI-555

SUNDI-575W

SUNDI-575

SUNDI-5A10W

SUNDI-5A10

SUNDI-5A15W

 

Temperature range ℃

-50℃~250℃

-50℃~250℃

-50℃~250℃

-50℃~250℃

-50℃~250℃

-50℃~250℃

Control Mode

Feed forward PID + Our special dynamic control calculation, PLC controller

Temp. control

Option: process temperature control or jacket oil temperature control

Temp. difference

Set or control the temperature difference between jacket oil and raw material process

Program Editor

20 programs, each program can edit 45 steps.

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium: PT100    Raw material process: PT100

Temp. accuracy

±1℃

±1℃

±1℃

±1℃

±1℃

±1℃

Heating power

2500W

3500W

5500W

7500W

10000W

15000W

Cooling

capacity

250℃

2000W

3500W

5500W

7500W

10000W

15000W

100℃

2000W

3500W

5000W

7000W

10000W

15000W

20℃

2000W

3500W

5000W

7000W

10000W

15000W

0℃

1800W

3000W

5000W

7000W

10000W

15000W

-20℃

850W

1500W

2850W

4200W

6000W

11000W

-40℃

250W

450W

900W

1500W

2000W

3750W

Circulation pump

Max20L/min

2BAR

Max20L/min

2BAR

Max35L/min

2BAR

Max50L/min

2.5BAR

Max50L/min

2.5BAR

Max110L/min

2.5BAR

Compressor

Tecumseh

Copeland

Copeland

Copeland

Copeland

Copeland

Expansion valve

Danfoss

Danfoss

Danfoss

Danfoss

Danfoss

Danfoss

Oil separator

Emerson

Emerson

Emerson

Emerson

Emerson

Emerson

Evaporator

KAORI Plate heat exchanger

Operation Panel

7-inch color touch screen controller,temperature curve record,data export to excel format.

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,

liquid low level protection, high temperature protection and temperature fault protection.

Closed
circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,

 pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Refrigerant

R-404A

R-404A

R404A

R404A

R404A

R404A

Connection size

DN-15 or

M24*1.5

DN15 or

M30*1.5

DN20 or

M30*1.5

DN20 or

M30*1.5

DN20 or

M30*1.5

DN-25

M38*1.5

Water-cooled type W

(cooling water at 20℃)

600L/H

1.5bar~4bar

800L/H

1.5bar~4bar

1500L/H

1.5bar~4bar

1800L/H

1.5bar~4bar

2600L/H

1.5bar~4bar

3200L/H

1.5bar~4bar

Dimension

water-cooled

400*600*1050

400*600*1050

600*700*1150

600*700*1150

600*700*1150

700*700*1250

air-cooled

 

 

550*680*1450

620*700*1450

700*700*1750

 

Weight

water-cooled

160kg

185kg

245kg

285kg

320kg

360kg

air-cooled

 

 

280kg

320kg

360kg

 

Power

AC 220V 50HZ

4.5kW (max)

AC 380V 50HZ

6.A5kW (max)

AC 380V 50HZ

9kW (max)

AC 380V 50HZ

12.5kW (max)

AC 380V 50HZ

16.5kW (max)

AC 380V 50HZ

24kW (max)

Case material

SUS 304

SUS 304

SUS 304

SUS 304

SUS304

SUS304

Optional

Optional Ethernet interface, configure PC operating software

Optional

Optional outside touch screen display controller (separated), the communication line distance is 10 meter.

Optional power

 220V 60HZ three-phase, 440V~480V 60HZ three-phase 

 

 

 Ancillary use and test area:

 

 

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

 

 

 

FAQ

2015 Corning Reactor and its Ancillary Equipment Technology Exchange Meeting

High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree 

 High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree

 

 

Contact Supplier

Ms. Lisa Li engineer Chat Now
Telephone
0086-510-82321181
Mobile
0086-17715697019
Fax
0086-510-82303782
Address
No.10, Zhenfa No.1 Road, New district, Wuxi, Jiangsu, China Wuxi,Jiangsu

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Refrigeration & Heat Exchange Equipment > Other Refrigeration & Heat Exchange Equipment
Categories
Hi~