UHZ 517C12D diesel fuel tank level gauge for fuel sensor gauge high temperature 520 centigrade high pressure PN16.0 900lb
Negotiable /Set
Min.Order:1 Set
Shanghai Xingshen Instrument Co., Ltd.
UHZ 517C12D gas level indicator for fuel tank gauge 520 centigrade 900lb
UHZ 517C12E liquid level indicator for fuel tank gauge 520 centigrade 1500lb
UHZ 517C13 low temperature tank gauging for frost proof -40~+100 centigrade
UHZ 517C14 magnetic level gauge for liquid gas level indicator -20~+100 centigrade 300lb
The products are widely used in electric power, petroleum, chemical, metallurgy,architecture and foodstuff industries.
Technique Parameter
Measure Range: | 150~8000mm (center distance) or on request. |
Nominal Pressure: | PN 15 MPa Class 900LB ANSI |
Working Pressure: | ≤11.25Mpa 675LB |
Working Temperature | 520°C ( 793.15K ) |
Medium Density | 500~2000kg/m³ |
Chamber(bypass tube) | Φ63.5×6mm |
Process Connection | Factorty Standard: DN25 PN 15MPa HG20592-97; 900LB 1" ANSI B16.5; Optional std: 1/2"~ 4" ANSI B16.5; DN10-DN100 GB/T 9112-2000; JB/T 79.1-94 SH3406-1996 DIN 2635; DN10-DN100; DIN 2527; DN10-DN100 10A~100A JIS 63K FF RF; 1/2"~4" JPI 900LB RF |
Chamber/Flange/ Wetted Material | 304, 316, 316L, 316Ti, 321, 1.4301, 1.4435, 1.4401, 1.4571, 1.4783, 0Cr18Ni9, 1Cr18Ni9Ti, 00Cr17Ni14Mo2, 0Cr17Ni12Mo2, 0Cr18Ni2Mo2Ti |
Magnetic Float | Its size depends on liquid density Material: Titanium, 316SS or 316L SS |
Optional Items |
|
Model Table
UHZ-517C12D | With blind flange, no drain valve | ||||||||||
L | Bottom drain valve | ||||||||||
G | Tri-magnet driven level switch | ||||||||||
GH | High temperature four-magnet driven level switch | ||||||||||
Control points(quantity of level switches) | |||||||||||
R | Ltransmitter two wire 4~20mA output | ||||||||||
R1 | LB transmitter HART two-wire 4~20mA output | ||||||||||
R2 | AT200 Magnetostrictive transmitter two-wire 4~20mA output HART | ||||||||||
R3 | AT201 Magnetostrictive transmitter three-wire 4~20mA output HART | ||||||||||
R4 | AT202 High temperature magnetostrictive transmitter output HART | ||||||||||
R5 | AT203 High temperature transmitter three-wire output HART | ||||||||||
D | ExdIIBT1~T6 Explosion proof | ||||||||||
E | ExiaIICT1~T6 Intrinsically safe | ||||||||||
EF | Intrinsically safe with barrier | W | Wide rollers board | ||||||||
Removable heating jacket | J2 | Sleeve type heating jacket | |||||||||
J3 | Coil type heat tracing device | J4 | Depth vacuum jacket | ||||||||
J5 | Depth vacuum insulation& compound heating jacket | ||||||||||
Installation height(N/A for side-side mounted level gauge | |||||||||||
(M)Measuring range,mm | |||||||||||
Medium density,kg/m3 | |||||||||||
Nominal pressure |