UHZ 517C13 vacuum gauge for refrigeration proof low temperature frost proof min -40 and -196 centigrade
Negotiable /Set
Min.Order:1 Set
Shanghai Xingshen Instrument Co., Ltd.
UHZ 517C14 magnetic level gauge for liquid gas level indicator -20~+100 centigrade 300lb
UHZ 517C10 fuel level controller for survey float level gauge max 200 centigrade 150lb
UHZ 517C10 float ball water level for magnetic liquid level gauge max 200 centigrade 150lb
UHZ 517C11 oil tank level gauge for fuel tank max 450 centigrade 150lb
Technique Parameter
Measure Range: | 150~8000mm (center distance) or on request. |
Nominal Pressure: | PN5.0 MPa Class 300LB ANSI |
Working Pressure: | ≤3.75Mpa 225LB |
Working Temperature | UHZ517C13: -40°C ~100°C (223.15~373.15K) UHZ517C13A: -196°C ~100°C (77.15~373.15K) |
Medium Density | 500~2000kg/m³ |
Chamber(bypass tube) | Φ63×4mm |
Process Connection | Factory Standard: DN25 PN5.0MPa HG20592-97; 300LB 1" ANSI B16.5; Optional std: 1/2"~ 2" ANSI B16.5; DN10-DN50 GB/T 9112-2000; JB/T 79.1-94 SH3406-1996 DIN 2635; DN10-DN50; DIN 2527; DN10-DN50 10A~50A JIS 20K FF RF; 1/2"~2" JPI 300LB RF |
Chamber/Flange/ Wetted Material | 304, 316, 316L, 316Ti, 321, 1.4301, 1.4435, 1.4401, 1.4571, 1.4783, 0Cr18Ni9, 1Cr18Ni9Ti, 00Cr17Ni14Mo2, 0Cr17Ni12Mo2, 0Cr18Ni2Mo2Ti |
Magnetic Float | Its size depends on liquid density Material: Titanium |
Optional Items | 1. Tri-magnet level switch 2. Quad-magnet level switch 3. Heating Jacket 4. Depth Vacuum heating jacket 5. Coil type heating jacket 6. Drain/Vent valves 7. Transmitter(4~20mA, two/ three wire,HART) 8. Magnetostrictive level transmitter |
UHZ-517C13 | With blind flange, no drain valve | ||||||||||
L | Bottom drain valve | ||||||||||
G | Tri-magnet driven level switch | ||||||||||
GH | High temperature four-magnet driven level switch | ||||||||||
Control points(quantity of level switches) | |||||||||||
R | Ltransmitter two wire 4~20mA output | ||||||||||
R1 | LB transmitter HART two-wire 4~20mA output | ||||||||||
R2 | AT200 Magnetostrictive transmitter two-wire 4~20mA output HART | ||||||||||
R3 | AT201 Magnetostrictive transmitter three-wire 4~20mA output HART | ||||||||||
R4 | AT202 High temperature magnetostrictive transmitter output HART | ||||||||||
R5 | AT203 High temperature transmitter three-wire output HART | ||||||||||
D | ExdIIBT1~T6 Explosion proof | ||||||||||
E | ExiaIICT1~T6 Intrinsically safe | ||||||||||
EF | Intrinsically safe with barrier | W | Wide rollers board | ||||||||
Removable heating jacket | J2 | Sleeve type heating jacket | |||||||||
J3 | Coil type heat tracing device | J4 | Depth vacuum jacket | ||||||||
J5 | Depth vacuum insulation& compound heating jacket | ||||||||||
Installation height(N/A for side-side mounted level gauge | |||||||||||
(M)Measuring range,mm | |||||||||||
Medium density,kg/m3 | |||||||||||
Nominal pressure |