Technique Parameter
Measure Range: | 150~8000mm (center distance) or on request. |
Nominal Pressure: | PN6.4MPa Class 400LB ANSI |
Working Pressure: | ≤4.8Mpa 300LB |
Working Temperature | 450°C 723.15K |
Medium Density | 500~2000kg/m³ |
Chamber(bypass tube) | Φ63.5×3mm |
Process Connection | Factorty Standard: DN25 PN 6.4MPa HG20592-97; 400LB 1" ANSI B16.5; Optional std: 1/2"~ 4" ANSI B16.5; DN10-DN100 GB/T 9112-2000; JB/T 79.1-94 SH3406-1996 DIN 2635; DN10-DN100; DIN 2527; DN10-DN100 10A~100A JIS 30K FF RF; 1/2"~4" JPI 400LB RF |
Chamber/Flange/ Wetted Material | 304, 316, 316L, 316Ti, 321, 1.4301, 1.4435, 1.4401, 1.4571, 1.4783, 0Cr18Ni9, 1Cr18Ni9Ti, 00Cr17Ni14Mo2, 0Cr17Ni12Mo2, 0Cr18Ni2Mo2Ti |
Magnetic Float | Its size depends on liquid density Material: Titanium, 316SS or 316L SS |
Optional Items |
|
Model Table
UHZ-517C12B | With blind flange, no drain valve | ||||||||||
L | Bottom drain valve | ||||||||||
G | Tri-magnet driven level switch | ||||||||||
GH | High temperature four-magnet driven level switch | ||||||||||
Control points(quantity of level switches) | |||||||||||
R | Ltransmitter two wire 4~20mA output | ||||||||||
R1 | LB transmitter HART two-wire 4~20mA output | ||||||||||
R2 | AT200 Magnetostrictive transmitter two-wire 4~20mA output HART | ||||||||||
R3 | AT201 Magnetostrictive transmitter three-wire 4~20mA output HART | ||||||||||
R4 | AT202 High temperature magnetostrictive transmitter output HART | ||||||||||
R5 | AT203 High temperature transmitter three-wire output HART | ||||||||||
D | ExdIIBT1~T6 Explosion proof | ||||||||||
E | ExiaIICT1~T6 Intrinsically safe | ||||||||||
EF | Intrinsically safe with barrier | W | Wide rollers board | ||||||||
Removable heating jacket | J2 | Sleeve type heating jacket | |||||||||
J3 | Coil type heat tracing device | J4 | Depth vacuum jacket | ||||||||
J5 | Depth vacuum insulation& compound heating jacket | ||||||||||
Installation height(N/A for side-side mounted level gauge | |||||||||||
(M)Measuring range,mm | |||||||||||
Medium density,kg/m3 | |||||||||||
Nominal pressure |