Micropilot M FMR230 of Radar level measurement
Negotiable /Piece
Min.Order:1 Piece
Xian Wellwork Industrial Co., Ltd.
measurement principle | Level radar | |
Characteristic / Application | For high pressures and temperatures | |
Supply / Communication | 2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus) | |
Frequency | C-band (~6 GHz) | |
Accuracy | +/- 10 mm | |
Ambient temperature | -40 °C...+80 °C (-40 °F...+176 °F) | |
Process temperature | -60 °C...+400 °C (-76 °F...+752 °F) | |
Process pressure absolute / max. overpressure limit | Vacuum...160 bar (Vacuum...2320 psi) | |
Main wetted parts | 316L, Alloy C | |
Process connection | Flange: DN80...DN250, ASME 3"...10", JIS 10K | |
Process connection hygienic | Tri-Clamp ISO2852 | |
Max. measurement distance | 20 m (65 ft) | |
Output | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus | |
Certificates / Approvals | ATEX, FM, CSA, IECEx, TIIS, NEPSI Overfill prevention WHG SIL EN10204-3.1 NACE Marine GL/ABS/NK | |
Options | DN80/DN100 for Bypass/Stilling well | |
Application limits | Maximum measuring range is dependent on the tank form and/or application Free space with nozzle FMR231, FMR240, FMR245 Stilling well with ball valve FMR240, FMR245 Hygiene requirements FMR231, FMR245 316L or Alloy C non-resistant FMR231, FMR245 |