Pressure transmitter with metal sensor
Overload-resistant and function-monitored; Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus
Your benefits
Cerabar S PMP71 with MID Parts Certificate:
Pressure transmitter with metal sensors
Overload-resistant and function-monitored; Communication via HART; Subcomponent suitable for custody transfer measurement with NMi approval
Your benefits:
High reference accuracy: up to ±0.075%, as PLATINUM version: ±0.05%
Used for process pressure monitoring up to SIL3, certified to IEC 61508 by TÜV SÜD
HistoROM®/M-DAT memory module
Function-monitored from the measuring cell to the electronics
Quick commissioning with Quick Setup menu
Menu-guided operation
The Cerabar S pressure transmitter is used for the following measuring tasks:
Cerabar S PMP71 with MID Parts Certificate:
Cerabar S serves as a component of a system suitable for custody transfer measurement, for highly accurate measurement of pressures, and finds application in
custody transfer. It satisfies the applicable requirements in accordance with OIML R117-1 Edition 2007 (E) and EN 12405-1/A1 Edition 2006.
The Parts Certificate is issued on the basis of the following standards:
The Cerabar S pressure transmitter is used for the following measuring tasks:
Measuring Principle | Hydrostatic | |
Characteristic | Digital transmitter with piezoresistive sensor and welded metallic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functionsSecondary process barrier | |
Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) | |
Accuracy | Standard 0,075% Platinum 0,05% | |
Long term stability | 0,05% of URL/year | |
Process temperature | -40°C...125°C (-40°F...257°F) | |
Ambient temperature | -40°C...85°C (-40°F...185°F) | |
Measuring range | 100mbar...700bar (1.5psi...10.500psi) | |
Max. overpressure limit | 1050bar (15.750psi) | |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2 Flange: DN25...DN80, ASME 1"...4", JIS 10K...20K | |
Output | 4...20mA HART PROFIBUS PA FOUNDATION Fieldbus | |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, NEPSI Overfill prevention WHG SIL EN10204-3.1 NACE Marine | |
Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing | |
Specialities | Diagnostic functions |