ISO CE ETCR4300 Intelligent 3-phase Volt-ampere Meter electrical meter Quality Choice
USD $410.67 - $766.67 /Piece
Min.Order:1 Piece
Guangzhou ETCR Electronic Technology Co., Ltd.
ETCR4300 Intelligent 3-phase Volt-ampere Meter
Product Features
1.It is able to measure three-phase AC voltage, current, phase between voltage, phase between current, the phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum simultaneously; judge the wiring type of transformer, inductive and capacitive circuits; also test secondary circuit and bus differential protection system, read the phase relationship between the CT for differential protection; besides, it can be used to check whether the wiring of the watt-hour meter is correct or not, and check the line equipment.
2.Measuring range: Phase: 0~360°; current: 0.0mA~20A;voltage:0~600V; power factor:0.0W~12kW;
3. Data upload: RS232 Interface
4.Data storage:500 sets
5.Clamp mouth:φ7.5mm
The ETCR4300 Three Phase Digital Phase Volt-Ampere Meter is a well-developed full-automatic, multi-functional, digital, intelligent meter specifically designed for field testing, featuring high accuracy, high stability, low power consumption, easiness to use and so on. It can directly measure AC voltage and AC current without opening the measured circuit, phases between three voltages, three currents and phase between the voltage and current; in addition, the power factor and power of the circuit can be indirectly measured, it can also be used to distinguish three-phase sequence, transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.
The ETCR4300 Three Phase Digital Phase Volt-Ampere Meter has well designed shell mould made of newest material, attach with shakeproof, skidproof, high insulation sheath, has a 240dots×160dots LCD screen, all the test data display on the screen simultaneously, vector diagram indication, and looks exquisite and comfortable. Meter equipped with USB-RS232 interface, can store 1500 sets of data, through the system software upload stored data to the computer, implementing online real-time monitoring and historical inquires, dynamic display. Can read, save, report, print history data, etc.
The ETCR4300 Three Phase Digital Phase Volt-Ampere Meter (Intelligent Three Phase Digital Phase Volt-Ampere Meter) applies to electric power, petroleum chemical industry, metallurgy, railway, and meteorology, industrial and mining enterprises, scientific research institutions, measurement sector and so on. Especially for the electricity billing system and relay protection system.
Technical Specifications
1.Base Conditions and Working Conditions
Influence quantity | Reference conditions | Working conditions | Remarks |
Ambient temperature | 23°C±1°C | -10°C ~ 40°C | ---- |
Ambient humidity | 40% ~ 60% | < 80% | ---- |
Signal waveform | Sine wave | Sine wave | β=0.01 |
Signal frequency | 50HZ±1HZ | 45HZ~65HZ | ---- |
Working voltage of meter | 9V±0.1V | 9V±1.5V | ---- |
Current magnitude when measuring the phase sequence of phase frequency | 1A±0.2A | 2mA ~ 20A | ---- |
Voltage magnitude when measuring the Phase sequence of phase frequency | 100V±20V | 10V~600V | ---- |
Current magnitude when measuring the power factor | 1A±0.2A | 20mA~20A | ---- |
Voltage magnitude when measuring the power factor | 100V±20V | 10V~600V | ---- |
External electric field, magnetic field | To be avoided | ||
Location of the tested wire | The tested wire is arranged at the approximate geometrical center of the clamp |
2. Intrinsic error and performance indicators under base conditions
Category | Range | Resolution | Basic error |
Voltage | AC 0.00V ~ 600V | 0.01V | ±(1.5%rdg+3dgt) |
Current(AC) | 0.0mA ~20.0A | 0.1mA | ±(1.5%rdg+3dgt) |
Phase | 0.0° ~ 360° | 0.1° | ±1° |
Active power | 0.0W~ 12kW | 0.1W | ±(3%rdg+3dgt) |
Reactive power | 0.0VAR ~ 12kVAR | 0.1VAR | ±(3%rdg+3dgt) |
Apparent power | 0.0VA ~ 12kVA | 0.1VA | ±(3%rdg+3dgt) |
Frequency | 45HZ ~ 65HZ | 0.01HZ | ±(2%rdg+3dgt) |
Power factor | -1 ~ +1 | 0.001 | ±0.03 |
Note : Under working conditions, the phase error is ± 3 °
(the error is doubled in case that the current amplitude is less than 10mA).
3.General specification
Functions | It is able to measure three-phase AC voltage, current, phase between voltage, phase between current, the phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum simultaneously; judge the wiring type of transformer, inductive and capacitive circuits; also test secondary circuit and bus differential protection system, read the phase relationship between the CT for differential protection; besides, it can be used to check whether the wiring of the watt-hour meter is correct or not, and check the line equipment. |
Power supply | DC9V Alkaline batteries (1.5V LR6×6) |
Power consumption | The maximum power consumption can be 80mA if the backlight is turned on, and the battery can work continuously for 10 hours |
The power consumption can be 50mA if the backlight is turned off, and the battery can work continuously for 16 hours | |
Display modes | LCD display, 240dots×160dots |
Dimensions of meter | L×W×: 196mm×92mm×54mm |
Dimensions of Clamp | 7.5mm×13mm |
Voltage range | AC 0.00V~600V |
Current range | AC 0.0mA~20.0A |
Phase range | 0.0°~360.0° |
Frequency range | 45.00Hz~65.00Hz |
Active power range | 0.0W~12kW |
Reactive power range | 0.0W~12kVAR |
Apparent power range | 0.0W~12kVA |
Power factor range | -1~+1 |
Current vector sum | 0mA~60.0A |
Resolution | Voltage: AC 0.01V |
Current: AC 0.1mA | |
Phase: 0.1° | |
Frequency: 0.01Hz | |
Active power: 0.1W | |
Reactive power: 0.1VAR | |
Apparent power: 0.1VA | |
Power factor: 0.001 | |
Current vector sum: 1mA | |
Phase sequence | Positive phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from left to right Negative phase: U1, U2, U3 or I1, I2, I3 cursor blinks sequentially from right to left |
Tested rate | About 2s/time |
Data retention | Press HOLD during the test to keep the data, and the symbol “HD” will be displayed. |
Data storage | 500 sets |
RS232 interface | USB-RS232 interface; all data stored are uploaded to the computer, to provide the convenience for data analysis and management. |
Automatic shutdown | The meter automatically shuts down about 15 minutes after start-up, as to reduce the battery consumption. |
Backlight function | Available, suitable for use in dark places or at night |
Voltage detection | When the battery voltage is below 7.2V, low voltage sign will be displayed to remind the user of replacing the battery. |
Meter mass | Host: 550g (with battery) |
Current clamp: 170g×3 | |
Test line: 250g | |
Length of test line | 1.5m |
Length of current clamp wire | 2m |
Working temperature and humidity | -10°C ~ 40°C; below 80%Rh |
Storage temperature and humidity | -10°C ~ 60°C; below 70%Rh |
Input impedance | Input impedance of test voltage: 2MΩ |
Withstand voltage | The withstand sine-wave AC voltage of 1000V/50Hz between the meter line and the shell can last for 1 minute. |
Insulation | The insulation resistance between the meter line and the jacket shell is ≥100MΩ |
Structure | Double insulation, with insulated vibration-proof jacket |
Applicable safety standards | IEC61010-1 CAT Ⅲ 600V, IEC61010-031, IEC61326 Pollution Degree 2 |
Accessories | Meter:1pc; Case:1piece; Clamp:3pcs; Test Line:4pcs; RS232 Line:1pc;Battery:6pcs |
Packing Size: (L ×W ×H): 350× 100×260(mm)
Weight: 2.5Kg
ETCR
More information, please kindly view our web site: /en/
Online store: /store/1119041