ETCR068 Clamp Leakage current sensor electrical meter
ETCR068 Clamp Leakage current sensor electrical meter
ETCR068 Clamp Leakage current sensor electrical meter
ETCR068 Clamp Leakage current sensor electrical meter
ETCR068 Clamp Leakage current sensor electrical meter
ETCR068 Clamp Leakage current sensor electrical meter

ETCR068 Clamp Leakage current sensor electrical meter

USD $73.5 - $105 /Piece

Min.Order:1 Piece

Supply Ability:
0 per Month
Port:
Guangzhou
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
ETCR
Model Number:
ETCR068
Usage:
Consumption Sensor
Theory:
Current Sensor
Output:
Digital Sensor

Guangzhou ETCR Electronic Technology Co., Ltd.

Business Type: Manufacturer
Guangzhou Guangdong China
Main Products: Phase Detector ,Damp Resistance Tester ,Current Meter ,Current Sensor ,Soft Magnetic Alloy Core

Product Details

ETCR068 Clamp Leakage current sensor

Product Information

ETCR068 Clamp Leakage current sensor electrical meterETCR068 Clamp Leakage current sensor electrical meter

Product Features

ETCR068 High Accuracy Clamp AC Leakage Sensor is used for measurement of high accuracy AC current, leakage current, high order harmonic current, phase, power energy, power, power factor. Adopt the latest CT technology. It is portable, large clamp design, no need to disconnect the measured circuits, non-contact, safe and fast. It can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, harmonic analyzer, electric power quality analyzer, high precision digital multi-meter, etc. Widely applied in electricity, communication, meteorology, railway, oilfield, construction, measurement, scientific and research teaching unit, industrial and mining enterprises.

 

ETCR068 High Accuracy Clamp AC Leakage Sensor’s clamp core is made of special alloy, adopt the double magnetic shielding techniques, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement. 

 

Model Difference  

Model

Range

Turn ratio

Frequency

Secondary output/load

Accuracy class

Size of clamp

(mm)

Dimension

(mm)

ETCR068

AC 1000A

1:2400

10Hz~100kHz

0~100mA≤3Kω;

0~10A≤30Ω;

0~1000A≤0.3Ω

±2%FS

φ68

185×115×43

ETCR068B

AC 1000A

1:1000

10Hz~100kHz

ETCR068C

AC 2000A

1:2400

45Hz~75Hz

0~200mA≤2kΩ;

0~20A≤20Ω;

0~2000A≤0.2Ω

ETCR068AD

DC 2000A

AC 1000A

Hall effect

45Hz~400Hz

DC~100KHz

1mV/A(DC0~2V) 1mV/A(AC 0~1V)

±2%FS

φ68

224×115×43

Note: Can customize according to customer’s requirement

Curve of ratio error and phase error(23±3)

 

Technical Specifications  

Function

Measurement of AC current, leakage current, high order harmonic current, phase, power energy, power, power factor

Test mode

Clamp CT

Clamp Size

φ68mm

Range

0.00mA~1000A

Resolution

0.01mA

Accuracy

±2.0%FS(50Hz/60Hz; 23±2, below 70%RH, keep the wire be in the center of clamp)

Coils Turn

Standard 2400:1(Customize is allowed)

Phase Error

≤3(50Hz/60Hz; 23±2)

Reference Load

RL: 0~100mA≤3Kohm; 0-10A≤30ohm; 0-1000A≤0.3ohm;

Output Mode

Current induction output

Output Interface

2 thread or chose standard probe of multi-meter

Output Wire Length

2m

Electric Field Interference

About 10mA when the external electric field 100A, 10mm nearby

Measured Wire Position

Approximately in the geometric center of the clamp

Current Frequency

45H-60Hz(when measuring big current)

Frequency Feature

10Hz~100kHz

Voltage of circuit

Below AC 600V

Dimension

185mmx115mmx43mm

Weight

530g

Working Environment

-20 ~ 50℃; below 80%rh

Storage Environment

-10℃ ~60℃; below 70%rh

Insulation Strength

AC 3700V/rms.(between coil and shell)

Safety Rules

IEC1010-1,IEC1010-2-032,Pollution degree:2 CAT(600V)

 

Packing     

Packing Case Size(L×W×H):247×145×70(mm)

Weight:0.57Kg

 

FAQ

Payment:

You could use online payment in ALIExpress here or other payment terms.

It is customer’s responsibility to pay import duties or taxes if it is necessary.

 

Products Warranty:

All of our products have two years of products warranty.

There will be professional engineers responsible for after sale service.

We could provide Technical supports to customers directly.

Thanks for your choice our products.

 

Company information

ETCR

A professional manufacturer of test and measure instrument.

We have our R&D department, top sales group, supply application services. ETCR Help you work safer and faster.

All of our products have two years products warranty.

There will be professional responsible for after sale service.

We are developing international market.

So every customer's identity is our best encouragement.

 

More information, please kindly view our web site: /en/

Online store:   /store/1119041

ETCR068 Clamp Leakage current sensor electrical meterETCR068 Clamp Leakage current sensor electrical meterETCR068 Clamp Leakage current sensor electrical meterETCR068 Clamp Leakage current sensor electrical meterETCR068 Clamp Leakage current sensor electrical meterETCR068 Clamp Leakage current sensor electrical meter

 

 

Contact Supplier

Ms. Lili Su Sales Manager Chat Now
Telephone
86-020-62199556
Mobile
13802922567
Fax
86-020-62199550
Address
F-3F,No.4 Pengshang Zhifu Road, Jiahe,Baiyun District,Guangzhou,Guangdong,China. Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors
Categories
Hi~