ETCR148A Super Large Caliber Clamp AC Current Probe(1:3000)(4000A)
USD $191.94 - $274.19 /Piece
Min.Order:1 Piece
Guangzhou ETCR Electronic Technology Co., Ltd.
ETCR148 Large Caliber Digital Clamp AC Current Probe(1:3000)(3000A)
ETCR148A Super Large Caliber Clamp AC Current Sensor(1:3000)(4000A)
ETCR148 Large Caliber Digital Clamp AC Current Transducer(1:3000)(3000A)
ETCR080D Large Caliber DC Clamp Current Sensor electrical instrument
ETCR 040 High Sensitivity Clamp AC Current Probe(10Hz~100Khz) electrical instrument
ETCR9500 Wireless HV CT Variable Ratio Leakage Current Tester electrical instrument
Welcome to ETCR
Our buyers have stayed with us for 12 years
12 years of specialized meters
ISO Patent and CE certificate
OEM services available
Function | Measurement of AC current, higher harmonic current, phase, electric energy, power and power factor |
Test Mode | Clamp CT |
Clamp Size | 148mm×108mm |
Measurement Range | AC 0.0A-4000A |
Resolution | AC 0.1A |
Accuracy | ±2.0%FS (50Hz/60Hz; 23°C±2°C, below 70%RH, keep the measured wire be in the center of the clamp) |
Coils Turn | 3000: 1 |
Phase Error | ≤3°(50Hz/60Hz; 23°C±2°C) |
Reference Load | RL: 0-300mA≤3kΩ; 0-30A≤30Ω; 0-4000A≤0.3Ω |
Output Mode | Current induction output |
Output Interface | 2 bare wires or standard multi-meter pen plug |
Lead length | 2m |
Electric Field Interference | About 5mA when the external electric field 100A, 10mm nearby |
Wire Position | Keep the measured wire be in the center of the clamp |
Current Frequency | 45Hz-60Hz (Frequency of the measured current) |
10Hz-100kHz | |
Circuit Voltage | Below 600V AC |
Size | Length 350mm × Width 180mm × Height 55mm |
Weight | 1.5kg |
Working Temperature and Humidity | -20°C-50°C, below 80%rh |
Storage Temperature and Humidity | -10°C-60°C, below 70%rh |
Insulation strength | AC3700V/rms(between core and shell) |
Safety Specifications | IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT Ⅲ(600V) |
Accessories | Current Sensor: 1 pc |