air cooled chemical reaction kettle water chiller
USD $3,200 - $3,500 /Set
Min.Order:1 Set
Dongguan Carno Machinery Co., Ltd.
ari cooled chemical reaction kettle water chiller
---professional in designing, manufacturing, supplying, installing and commissioning the air cooled chemical reaction kettle water chillers for chemical reaction kettle cooling whose cooling capacities range from 2 ton to 600 ton
features
1.To adopt world superb compressors from Sanyo, Bitzer, Copland, Hanbell, Daikin, etc and pumps from Minamoto since 1986 and internal electric pars from Schneider or Siemens to ensure safe & quiet running ,
power saving and durable service life.
2. To employ microcomputer with easy operation which can control temperature within ±3°C to ±5°C precisely.
3. Unique design for condenser and heat- dispersion unit result in excellent heat-exchange effect.
4. To equip with electrical current overload protection, high & low-pressure switch, electronic timer delay
safety device. It will alarm to display faulty while any malfunction occurs.
5. To adopt with internal 304 stainless steel insulated water tank with durable service life for easy cleaning &
maintenance.
6. Complete safety devices including power reverse phase & power short phase and anti-freeze protection.
7. Ultra low temperature type of chillers can reach below -30°C.
8. Chillers for anti-alkaline & anti-acid type can be customized.
technical parameters of air cooled chemical reaction kettle water chiller
Operation Manual
1.1 Preparation to start
1.1.1 Check the machine is in good condition, the tubes are connected correctly, the cable is connected
correctly, and the power meets the requirement of relative regulations.
1.1.2 All the adjust valve is on right position. The cooling tower is running with full water.
1.1.3 Before turning on the machine, please turn on the chilling water pump to confirm that the cooling
there is enough water in tower.
1.2. Machine Running
1.2.1 After checking the cables and the tubes, turn the power switch, the power will first check the phase
sequence, if the phase is reversed, the trouble light is on, please change the sequence of any two power
phase and then re-turn on the machine.
1.2.2 First turn on the water pump. After the chilling water is circulating, turn on the compressor and adjust
the relative temperature, the machine enters automatic delay start state. Pay attention to that the temperature
predetermined should not be lower than 5°C, in order to avoid freezing.
1.3 For the first time the compressor is turned on, the following items should be paid attention:
a) First offer the machine power supply more than 12 hours.
b) The operator should first be family with the control box and its function.
1.4 Operation
a) Start up operation
1) First turn on the cooling pump and the cooling tower, confirm their running is normally.
2) Press ON key, then compressor enter delayed starting up.
3) Press COMP1, COMP2 key to choose the compressor.
b) close down operation
1) Press OFF key when the compressor is running, compressor will enter delayed running off.
2) Turn off the cooling pump and the cooling tower.
1.4.4 Water temperature setup
Click the SET key, and use the up or down-ward key to select the suitable working temperature,
and then click the SET key to confirm.
technical diagram of air cooled water chillers
the overseas project diagram
Carno air cooled water chillers control boards
products and detailed drawings (compressor and part of the condenser)
air cooled water chiller assembling workshop
large-sized oversea project