UV-6100PC Lab Double Beam Spectrophotometer LCD

UV-6100PC Lab Double Beam Spectrophotometer LCD

USD $4,500 - $4,900 /Unit

Min.Order:1 Unit

Supply Ability:
300 Unit / Units per Month
Port:
SHANGHAI
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
CHINCAN
Model Number:
UV-6100PC
Size:
589*428*200mm
Weight:
22kg
Focal Length:
Photometric Range: 0-200%T,-0.3-3A

Hangzhou Chincan Trading Co., Ltd.

Business Type: Trading Company
Hangzhou Zhejiang China
Main Products: Laboratory Equipments ,Freeze Dryer ,Water Distiller ,Ultrasonic Cleaner ,Heating mantle

Product Details

Product Description

UV-6100PC DOUBLE BEAM SPECTROPHOTOMETER

 

UV-6100PC is an advanced double beam design,with 1.8nm fixed bandwidth, the two detectors measure sample and reference respectively and simultaneously for optimizing measurement accuracy.They provide excellent performance for measurements in the range of 190 to 1100nm, the memory is 32K. They are suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analysis, kinetics, wavelength scan, multiple components and DNA/Protein, PC Windows application software make these instruments versatile. All instruments provide excellent performance for measurements.

 

Specifications  

Model

UV-6100PC

Wavelength Range

190-1100nm

Spectral Bandwidth

1.8nm

Optical System

Double Beam,Grating 1200 lines/mm

Wavelength Accuracy

±0.3nm

Wavelength Repeatability

0.2nm

Scan Speed

Hi,MED.,LOW., MAX.3000nm/min

Photometric Accuray

±0.3%T or ±0.003A@1A

Photometric Range

0-200%T,-0.3-3A

Stray Light

0.04%T@220nm,360nm

Stability

0.0003A/h@500nm

Display

5 inches LCD (320*240 dots)

Baseline Flatness

±0.0005A

Standard Cell Holder

Standard 10mm single cell holder (2pcs)

Sample Compartment

Standard 10mm pathlength cuvette

Light Source

Tungsten & Deuterium lamp (pre-aligned)

 

Output

USB Type A port for USB memory device(Right side)

USB Type B port for optional computer connectivity (Back)

Parallel Port for Printer

Power Requirement

AC 110/220V 50/60HZ

Dimension(L*W*H)

589*428*200mm

Weight

22kg

 

Features

1. Fixed bandwidths.

2. Sealed, solvent-resistant tactile keypad with alpha-numeric entry for file names and units.

3. Pre-aligned deuterium lamp for easy lamp replacement. The status of the lamps may be monitored

4. Powerful built-in program based software UV/Vis Analyst including sophisticated utility programs.

5. Data Download-to-PC software for stand-alone models (Optional)

6. Real-time clock for date and time stamping of results.

7. Data can be saved by USB memory device directly.

 UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Brief Function Introduction

All methods are included as built-in standard; this eliminates the need of software. Online software update via internet.

The local control software includes functions such as: Photometry, Quantitative, Wavelength Scan, Kinetics,DNA/Protein, Multi-wavelength and System Utilities.

UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Standard Curve

Up to 10 standard solutions may be used to establish calibration equation curve. There is a choice of four methods for fitting a curve through the calibration points: Linear fit, Linear fit through zero, square fit and cubic fit.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Multi-Wavelength

Up to 10 wavelengths may be entered, allowing the measurement of multiple wavelengths on a series of samples.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Wavelength Scan

The Wavelength Scan intervals are 0.1, 0.2, 0.5, 1, 2, 5nm, and High, Medium and Low scan speeds are available. Scan speeds vary from 100 to 2000 nm/min. Wavelengths are scanned from high to low so that the instrument stand by at high wavelength. This minimizes the degradation of UV sensitive samples. Precise control of filter and lamp changes means that their effects are not seen on the final scan. Post-run manipulation includes re-scaling axes, curve tracking and peak picking.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Kinetics

This mode may be used for scanning time course or reacting rate calculations. Abs. vs. time graphs is displayed on the screen in real time.

Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1, 2,5, 10, 30, seconds and 1 min.

Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

DNA/Protein Test

Concentration and DNA purity are calculated by

Absorbance ratios 260nm/280nm or 260nm/230nm with optional subtracted absorbance at 320nm

DNA Concentration=62.9*A260-36.0*A280

Or 49.1*A260-3.48*A230

Protein Concentration=1552*A260-757.3*A280

Or 183*A260-75.8*A230

Other wavelengths and factors may be entered.

  UV-6100PC Lab Double Beam Spectrophotometer LCD 

 

UV Analyst Software (PC-Control software)

The PC application software UV/Vis Analyst takes the best features of the stand-alone version plus more powerful data processing, expanded data collecting, and storage capability. It comes standard with UV3/6 series PC models and is optional to stand-alone models.

 

The PC application software offers

1. Photometric Mode

2. Quantitative test (Standard curve)

3. Wavelength Scan

4. Kinetics

5. DNA/Protein

6. Multi-Wavelength

7. System Utility

 

Quantitative Test (Standard curve)

Use up to 20 standards to establish standard curve. Four methods for fitting a curve:

1. Linear fit

2. Linear through zero

3. Square fit

4. Cubic fit

UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Multi-wavelength

Up to 20 wavelengths can be selected and multiple samples can be measured. (Auto cell changer is required to run multiple samples automatically)

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Wavelength Scan

Automatically record peaks and valleys. The quantity of channels is unlimited; you can simultaneously store as many as desired. Post-run manipulation and processing includes:

1. Re-scaling axes, curve.

2. 1st to 4th derivative.

3. Smoothing, combination, zooming, overlap.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

Kinetics (Abs. VS Time)

The Kinetics mode may be used for scanning time course or reacting rate calculations. Abs. VS Time graphs are displayed on the screen in real time. Wait time, measurement time and time intervals may be entered.

Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

 

DNA/Protein

Concentration and DNA purity are quickly and easily calculated:

Absorbance ratios 260nm/280nm with optional subtracted absorbance at 320nm.

DNA Concentration=62.9*A260-36.0*A280

Protein Concentration=1552*A260-757.3*A280

Other wavelengths and factors may be entered.

  UV-6100PC Lab Double Beam Spectrophotometer LCD

Packaging & Shipping

  UV-6100PC Lab Double Beam Spectrophotometer LCD

Company Information

 UV-6100PC Lab Double Beam Spectrophotometer LCD

Contact Supplier

Mr. Tom Fang Chat Now
Telephone
0086-571-87977725
Address
No.56 Liuhe Rd. Hangzhou,Zhejiang