AA320N/AA4530F Lab Atomic Absorption Spectrophotometer Quality Choice
USD $3,000 - $10,000 /Set
Min.Order:1 Set
Hangzhou Chincan Trading Co., Ltd.
V-3000PC Scaning Spectrophotometer Visible Wavelength Range: 320-1100nm
UV-3000PC/UV-3100PC Scaning Spectrophotometer UV Visible Spectrophotometer
V-3000 Scaning Spectrophotometer Visible Wavelength Range: 320-1100nm
UV-3000/UV-3100 Scaning Spectrophotometer UV-Visible Spectrophotometer Single Beam
V-1600PC/UV-1600PC/V-1800PC/UV-1800PC UV-Visible Spectrophotometer single beam with PC software
V-1600/UV-1600/V-1800/UV-1800 UV-Visible Spectrophotometer Single beam Visible spectrophotometer
AA320N Atomic Absorption Spectrophotometer
COMMON FEATURES
1. Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
3. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
5. High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.
6. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
7. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.
9. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
SPECIFICATIONS
WL range | 190-900nm |
WL accuracy | ≤±0.5nm |
WL repeatability | ≤0.3nm (single direction) |
Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base line stability | ±0.004Abs/30min |
Characteristic concentration of copper | ≤ 0.04μg/ml/1% |
Detection limit of copper | ≤0.008μg/ml |
Background calibration ability | Greater than 30 times |
RS232 | including |
Printer | optional |
Power supply | 220V 3A, 50Hz |
G.W. | 160Kg |
| 65Kg |
Package Dimensions | 1220x770x730mm (Main instrument) |
| 800x400x900mm ( Accessories ) |
STANDARD ACCESSORIES
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit
Burner unit
Dust cover
Water-separating gas filter
Titanium burner---10cm
OPTIONAL ACCESSORIES
Model GA3202 HGA graphite furnace system
Hydride generator
Graphite tubes
Software
Recirculating cooling water system
AA4530F Atomic Absorption Spectrophotometer
CHARACTERISTICS
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background regulation.
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flame absorption method and emission method.
10. Result printing: parameter printing, data result printing and diagram printing.
COMPLETE AUTOMATIC CONTROLLING SYSTEM
With the help of the software, the following can be easily achieved
1. Selection of the element lamp
2. Up-down-front-rear adjustment of the lifter
3. Adjustment of the optical energy
4. Selection of the slit
5. Determination of wavelength scanning and peak searching
6. Selection of the atomizer
7. Setting of the background deduction method
8. Controlling of the gas flow
9. Automatic flaming and flaming out
10.Setting of the graphite furnace testing method
ADVANCED GRAPHITE FURNACE TEMPERATURE CONTROLLING TECHNOLOGY
1. The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data.
2. The fast heating capacity can improve the flexibility of the elements further
3. Use the ordinary power source of 220V without need of dynamic power of 380V
4. The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
5. Three grades adjustable gas flow can accustom to more application needs
6. Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error
SAFE, RELIABLE AND CONVENIENT FLAME SYSTEM
1. EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily
2. Efficient atomization system enables a higher sensitivity
3. The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit temper ing. Thus
it keeps the operation people and equipment from harm and damage.
MULTI-FUNCTIONAL SOFTWARE WORKSTATION
1. A workstation that is supported WINDOWS XP/2000/NT
2. The rich menu brings great convenience to the use of customer
3. Convenient conversion between different menus makes the operation more easily
4. Various analytical correction methods provide the users more choices
5. Basic default parameter settings enable even the beginners can do the normal operation
6. Flexible storage, editing and printing methods give the user largest support
AA4530F Atomic Absorption Spectrophotometer
SPECIFICATIONS
Wavelength range | 190 – 900nm |
Spectral bandwidth | 0.1, 0.2, 0.4, 1.0 and 2.0nm |
Accuracy of the wavelength | ±0.15nm |
Receptivity of the wavelength | ≤0.04nm |
Base line stability | ≤0.002A/30min (Cu) |
Characteristic viscosity | 0.02μg/ml/1% (Cu) |
Checking limit | 0.004μg/ml (Cu) |
Preciseness | 0.50% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | 8 |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Size and weight | 700mm×550mm×450mm 75Kg |
Power source | 220V±22V AC |
FLAME SYSTEM
Acetylene air burner | 100mm |
Ignition dynamic baseline drift | ≤0.006A/30min |
(Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. |
GRAPHITE FURNACE
The highest temperature | 3000℃ |
The largest temperature rising speed | ≥2000℃/S |
Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
Accuracy | Cu≤3% Cd≤3% |
Size and weight | 550mm×450mm×300mm 65Kg |
Safety system | Over current protection |
Power source and power | 220V±22V AC 7000W |
STANDARD ACCESSORIES
PC workstation
HP inkjet printer
Oil free Air compressor
Acetylene reducing valve
Cu Hollow cathode lamp
Air filter
This year Shipping shows:
Established in 2004, Hangzhou Chincan Trading Co., Ltd. is a foreign trading company authorized by Chinese State Department of Foreign Economy & Trade and General Administration of Chinese Customs, which located in Hangzhou city, Zhejiang province, China.
We are a specialist company committed to exporting laboratory instruments, educational apparatus, medical & hospital equipments. With its superior performance, Chincan instruments are sold well throughout the Americas, Asia Pacific, the Middle East, Africa and Europe. With our excellent service, Chincan Trading has won a good reputation from the market.
Cooperative factories which qualified by Chincan come from many provinces and cities across China. All of them need to be ISO certified, Some products have CE.
Q: What after-sales service can be provided by CHINCAN ?
A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users can send us emails or call us about detailed information. We will provide users solution or operation video.For so many years’ experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would like to provide spare parts for free.
Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance?
A: We will be customer oriented,and make concessions in some principles , we will properly handle the disputes to maximize customer's satisfaction.
Normally all CHINCAN products are supplied with a warranty of 12 Months from the date of shipment. This warranty is entirely dependent on the following conditions:
1.The following circumstance don't belong to the warranty policy which is Man-made damages caused by improper operations.
2.The instruments must be operated in accordance with our operating guidelines; serviced and maintained on a regular basis in accordance with the terms specified in the relevant user manual.
3. Only approved spare parts should be used in the instruments which bought from CHINCAN and these should be changed on a regular basis as specified in the relevant user manual. Details of the approved spare parts and accessories for each instrument are shown in the user manual or alternatively this information can be obtained from CHINCAN.