Water flow is 50m3 per hour Round Cooling water tower for water cooling system
USD $875 - $985 /Set
Min.Order:1 Set
Wenzhou Sanhe Refrigeration Equipment Co., Ltd.
Water flow is 60m3 per hour Round Water cooling tower with FRP filling material
Water flow is 50m3 per hour Round counter current FRP Cooling tower system
Water flow is 70m3 per hour Round counter current Cooling water tower machine
Inlet water temperature is above 60degree C Round counter current Water cooling tower system
Water flow is 80m3 per hour Round counter current Water cooling tower system
Water flow is 90m3 per hour Round counter current Cooling water tower price list
Water flow is 50m3 per hour Round Cooling water tower for water cooling system
I. Cooling water tower Working condition :
Water inlet temperature:80°C
Water outlet temperature:50°C
Wet bulb temperature:28°C
Dry bulb tem peranure:31.8°C
Atmospheric pressure:9.94×10000Pa
Material: glass fiber reinforced plastic (GFRP)
cooling water tower structure photo
II. Technology parameter of Cooling water tower :
Model
| Water flow | Fan diameter | Theoretical air | Motor power | Tower height | Tower diameter | Weight |
(m3/h) | (mm) | (m3/h) | (kw) | (mm) | (mm) | (kg) | |
XTH-8 | 8 | 584 | 4500 | 0.18 | 1560 | 930 | 64 |
XTH-10 | 10 | 584 | 5700 | 0.18 | 1670 | 1000 | 85 |
XTH12 | 12 | 760 | 6800 | 0.37 | 1700 | 1100 | 94 |
XTH-15 | 15 | 760 | 9100 | 0.37 | 1780 | 1250 | 124 |
XTH-20 | 20 | 760 | 11300 | 0.37 | 1780 | 1400 | 158 |
XTH-25 | 25 | 760 | 15000 | 0.55 | 1780 | 1400 | 174 |
XTH-30 | 30 | 884 | 17000 | 0.75 | 1960 | 1620 | 185 |
XTH-40 | 40 | 884 | 21000 | 0.75 | 2010 | 1740 | 192 |
XTH-50 | 50 | 884 | 23000 | 1.1 | 2010 | 1840 | 215 |
XTH-60 | 60 | 1190 | 28000 | 1.1 | 2400 | 2200 | 412 |
XTH-70 | 70 | 1190 | 33000 | 1.5 | 2530 | 2200 | 476 |
XTH-80 | 80 | 1470 | 45000 | 2.2 | 2680 | 2500 | 680 |
XTH-90 | 90 | 1470 | 48000 | 2.2 | 2710 | 2500 | 730 |
XTH-100 | 100 | 1470 | 50000 | 2.2 | 2820 | 2900 | 776 |
XTH-125 | 125 | 1800 | 57000 | 4 | 3130 | 3300 | 954 |
XTH-150 | 150 | 1800 | 70000 | 4 | 3350 | 3300 | 1062 |
XTH-175 | 175 | 1800 | 85000 | 4 | 3670 | 3600 | 1468 |
XTH-200 | 200 | 1800 | 99000 | 4 | 3900 | 4000 | 1797 |
XTH-225 | 225 | 2400 | 113000 | 5.5 | 4165 | 4500 | 1987 |
XTH-250 | 250 | 2400 | 142000 | 5.5 | 4290 | 4500 | 2370 |
XTH-300 | 300 | 3000 | 171000 | 7.5 | 4435 | 4900 | 2495 |
XTH-350 | 350 | 3000 | 210000 | 11 | 4735 | 5300 | 2702 |
XTH-400 | 400 | 3400 | 228000 | 11 | 4820 | 6100 | 3592 |
XTH-450 | 450 | 3400 | 285000 | 15 | 4820 | 6100 | 3741 |
XTH-500 | 500 | 3700 | 342000 | 15 | 5145 | 6800 | 4276 |
XTH-600 | 600 | 3700 | 400000 | 18.5 | 5145 | 6800 | 4457 |
XTH-700 | 700 | 4200 | 456000 | 22 | 5732 | 8000 | 6167 |
XTH-800 | 800 | 4200 | 570000 | 22 | 5732 | 8000 | 6445 |
III. Water filter of Cooling water towers :