Water flow is 50m3 per hour Round counter current FRP Cooling tower system
USD $875 - $985 /Set
Min.Order:1 Set
Wenzhou Sanhe Refrigeration Equipment Co., Ltd.
Water flow is 70m3 per hour Round counter current Cooling water tower machine
Inlet water temperature is above 60degree C Round counter current Water cooling tower system
Water flow is 80m3 per hour Round counter current Water cooling tower system
Water flow is 90m3 per hour Round counter current Cooling water tower price list
Water flow is 100m3 per hour Round counter current Glass fiber Water tower system price
Big Round counter current Glass fiber Water cooling tower system price list
Water flow is 50m3 per hour Round counter current FRP Cooling tower system
I. FRP cooling tower system Working condition :
Water inlet temperature:37°C
Water outlet temperature:32°C
Wet bulb temperature:28°C
Dry bulb tem peranure:31.8°C
Atmospheric pressure:9.94×10000Pa
Material: glass fiber reinforced plastic (GFRP)
cooling water tower structure photo
II. Technology parameter of FRP cooling tower system :
Model
| Water flow | Fan diameter | Theoretical air | Motor power | Tower height | Tower diameter | Weight |
(m3/h) | (mm) | (m3/h) | (kw) | (mm) | (mm) | (kg) | |
XTM-8 | 8 | 584 | 4500 | 0.18 | 1560 | 930 | 64 |
XTM-10 | 10 | 584 | 5700 | 0.18 | 1670 | 1000 | 85 |
XTM-12 | 12 | 760 | 6800 | 0.37 | 1700 | 1100 | 94 |
XTM-15 | 15 | 760 | 9100 | 0.37 | 1780 | 1250 | 124 |
XTM-20 | 20 | 760 | 11300 | 0.37 | 1780 | 1400 | 158 |
XTM-25 | 25 | 760 | 15000 | 0.37 | 1780 | 1400 | 174 |
XTM-30 | 30 | 884 | 17000 | 1.1 | 1960 | 1620 | 185 |
XTM-40 | 40 | 884 | 21000 | 1.1 | 2010 | 1740 | 192 |
XTM-50 | 50 | 884 | 23000 | 1.1 | 2010 | 1840 | 215 |
XTM-60 | 60 | 1190 | 28000 | 1.5 | 2400 | 2200 | 412 |
XTM-70 | 70 | 1190 | 33000 | 1.5 | 2530 | 2200 | 476 |
XTM-80 | 80 | 1470 | 45000 | 2.2 | 2680 | 2500 | 680 |
XTM-90 | 90 | 1470 | 48000 | 2.2 | 2710 | 2500 | 730 |
XTM-100 | 100 | 1470 | 50000 | 2.2 | 2820 | 2900 | 776 |
XTM-125 | 125 | 1800 | 57000 | 4 | 3130 | 3300 | 954 |
XTM-150 | 150 | 1800 | 70000 | 4 | 3350 | 3300 | 1062 |
XTM-175 | 175 | 1800 | 85000 | 4 | 3670 | 3600 | 1468 |
XTM-200 | 200 | 1800 | 99000 | 4 | 3900 | 4000 | 1797 |
XTM-225 | 225 | 2400 | 113000 | 5.5 | 4165 | 4500 | 1987 |
XTM-250 | 250 | 2400 | 142000 | 5.5 | 4290 | 4500 | 2370 |
XTM-300 | 300 | 3000 | 171000 | 7.5 | 4435 | 4900 | 2495 |
XTM-350 | 350 | 3000 | 210000 | 11 | 4735 | 5300 | 2702 |
XTM-400 | 400 | 3400 | 228000 | 11 | 4820 | 6100 | 3592 |
XTM-450 | 450 | 3400 | 285000 | 15 | 4820 | 6100 | 3741 |
XTM-500 | 500 | 3700 | 342000 | 15 | 5145 | 6800 | 4276 |
XTM-600 | 600 | 3700 | 400000 | 18.5 | 5145 | 6800 | 4457 |
XTM-700 | 700 | 4200 | 456000 | 22 | 5732 | 8000 | 6167 |
XTM-800 | 800 | 4200 | 570000 | 22 | 5732 | 8000 | 6445 |
III. Water filter of FRP Cooling tower system :
standard type tower water filter XTM series
High temperature tower water filter XTH series , inlet water temperature is above 60degree C
FRP shells for cooling towers
IV. Cooling water tower photos :
In Ningbo port ready for shipping photo