Round Cooling Tower Price
USD $1,980 - $2,480 /Set
Min.Order:1 Set
Wenzhou Sanhe Refrigeration Equipment Co., Ltd.
Round Cooling Tower Price
I. Description of Water cooling tower :
Cooling towers are using water and the air contact, through the evaporation to disperse industry or refrigeration and air conditioning in the produce of waste heat of a device.
The work principle is: dry (low enthalpy) for air after fan after the twitch, since into wind nets place into the cooling tower;
Saturated steam partial pressure of high temperature water molecules to the low pressure air flow, hot and humid (high enthalpy) of water from water system was sprinkled into the tower.
When water and air contact, on the one hand, because of the air and water direct heat transfer,
on the other hand because water vapor surface and air pressure difference between the pressure being under the function of evaporation phenomenon, namely the quantity of heat of water evaporation heat transfer away,
so as to achieve the purpose of cooling.
II. Water cooling tower Working condition :
Water inlet temperature:37°C
Water outlet temperature:32°C
Wet bulb temperature:28°C
Dry bulb tem peranure:31.8°C
Atmospheric pressure:9.94×10000Pa
Material: glass fiber reinforced plastic (GFRP)
Water cooling tower structure
III. Technology parameter of Water cooling tower system:
Model
| Water flow | Fan diameter | Theoretical air | Motor power | Tower height | Tower diameter | Weight |
(m3/h) | (mm) | (m3/h) | (kw) | (mm) | (mm) | (kg) | |
XTM-8 | 8 | 584 | 4500 | 0.18 | 1560 | 930 | 64 |
XTM-10 | 10 | 584 | 5700 | 0.18 | 1670 | 1000 | 85 |
XTM-12 | 12 | 760 | 6800 | 0.37 | 1700 | 1100 | 94 |
XTM-15 | 15 | 760 | 9100 | 0.37 | 1780 | 1250 | 124 |
XTM-20 | 20 | 760 | 11300 | 0.37 | 1780 | 1400 | 158 |
XTM-25 | 25 | 760 | 15000 | 0.55 | 1780 | 1400 | 174 |
XTM-30 | 30 | 884 | 17000 | 0.75 | 1960 | 1620 | 185 |
XTM-40 | 40 | 884 | 21000 | 0.75 | 2010 | 1740 | 192 |
XTM-50 | 50 | 884 | 23000 | 1.1 | 2010 | 1840 | 215 |
XTM-60 | 60 | 1190 | 28000 | 1.1 | 2400 | 2200 | 412 |
XTM-70 | 70 | 1190 | 33000 | 1.5 | 2530 | 2200 | 476 |
XTM-80 | 80 | 1470 | 45000 | 2.2 | 2680 | 2500 | 680 |
XTM-90 | 90 | 1470 | 48000 | 2.2 | 2710 | 2500 | 730 |
XTM-100 | 100 | 1470 | 50000 | 2.2 | 2820 | 2900 | 776 |
XTM-125 | 125 | 1800 | 57000 | 4 | 3130 | 3300 | 954 |
XTM-150 | 150 | 1800 | 70000 | 4 | 3350 | 3300 | 1062 |
XTM-175 | 175 | 1800 | 85000 | 4 | 3670 | 3600 | 1468 |
XTM-200 | 200 | 1800 | 99000 | 4 | 3900 | 4000 | 1797 |
XTM-225 | 225 | 2400 | 113000 | 5.5 | 4165 | 4500 | 1987 |
XTM-250 | 250 | 2400 | 142000 | 5.5 | 4290 | 4500 | 2370 |
XTM-300 | 300 | 3000 | 171000 | 7.5 | 4435 | 4900 | 2495 |
XTM-350 | 350 | 3000 | 210000 | 11 | 4735 | 5300 | 2702 |
XTM-400 | 400 | 3400 | 228000 | 11 | 4820 | 6100 | 3592 |
XTM-450 | 450 | 3400 | 285000 | 15 | 4820 | 6100 | 3741 |
XTM-500 | 500 | 3700 | 342000 | 15 | 5145 | 6800 | 4276 |
XTM-600 | 600 | 3700 | 400000 | 18.5 | 5145 | 6800 | 4457 |
XTM-700 | 700 | 4200 | 456000 | 22 | 5732 | 8000 | 6167 |
XTM-800 | 800 | 4200 | 570000 | 22 | 5732 | 8000 | 6445 |
Water cooling tower shells photo
Inlet water filter photo
Water cooling tower photos